Updated on 2024/12/27

写真a

 
MATSUDA Tsuyoshi
 
Organization
Brain Research Institute Center for Integrated Human Brain Science Specially Appointed Assistant
Title
Specially Appointed Assistant
External link

Degree

  • 医科学 ( 2016.3   岩手医科大学 )

Research Interests

  • Magnetic Resonance

  • Magnetic resonance spectroscopy

  • 7T MRI

Research Areas

  • Energy Engineering / Quantum beam science  / Magnetic resonance

  • Life Science / Radiological sciences  / Magnetic resonance

Research History

  • Niigata University   Brain Research Institute Center for Integrated Human Brain Science   Specially Appointed Assistant

    2020.5

Education

  • Iwate Medical University   The Graduate School of Medicine   Master's Course

    2016.4 - 2018.3

      More details

    Country: Japan

    researchmap

  • The Open University of Japan   Faculty of Liberal Arts   Department of Liberal Arts

    1999.4 - 2002.3

      More details

    Country: Japan

    researchmap

  • Kyoto radiological technology college

    1980.4 - 1983.3

      More details

    Country: Japan

    researchmap

 

Papers

  • Diagnostic accuracy of preoperative quantitative susceptibility mapping for detecting histologic intraplaque hemorrhage in cervical ICA stenosis in patients undergoing carotid endarterectomy. International journal

    Daisuke Oomori, Yosuke Akamatsu, Ikuko Uwano, Futoshi Mori, Tsuyoshi Matsuda, Ryo Sugimoto, Michiko Suzuki, Shunrou Fujiwara, Masakazu Kobayashi, Makoto Sasaki, Kunihiro Yoshioka, Naoki Yanagawa, Kuniaki Ogasawara

    AJNR. American journal of neuroradiology   2024.5

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    BACKGROUND AND PURPOSE: Quantitative susceptibility mapping (QSM) has been proposed to assess intraplaque hemorrhage (IPH) in the carotid artery. The purpose of this study was to compare the diagnostic accuracy of preoperative QSM with that of the conventional T1-weighed (T1W) three-dimensional (3D)-FSE sequence for detecting IPH in cervical ICA stenosis in patients undergoing carotid endarterectomy (CEA) using histology as the reference standard. MATERIALS AND METHODS: Carotid T1W 3D-FSE and QSM images were obtained from 16 patients with cervical ICA stenosis before CEA. Relative signal intensity (RSI) and susceptibility of the ICA were measured on three axial images including the location of most severe stenosis on T1W 3D-FSE and QSM images, respectively. Three transverse sections of carotid plaques excised by CEA, which corresponded with images on MRI, were stained with H&E, antibody against glycophorin A and Prussian blue, and the relative area (RA) of histologic IPH was calculated. RESULTS: The correlation coefficient was significantly greater between susceptibility and RA-histologic IPH (ρ = 0.691) than between RSI and RA-histologic IPH (ρ = 0.413; P = .0259). The areas under the receiver operating characteristic curves for detecting histologic sections consisting primarily of IPH (RA-histologic IPH > 40.7%) tended to be greater for susceptibility (0.964) than for T1WI FSE-RSI (0.811). Marginal homogeneity was observed between susceptibility and histologic sections consisting primarily of IPH (P = .0412) but not between T1W FSE-RSI and histologic sections consisting primarily of IPH (P = .1824). CONCLUSIONS: Pre-CEA QSM detects histologic IPH in cervical ICA stenosis more accurately than preoperative T1W 3D-FSE imaging. ABBREVIATIONS: QSM = quantitative susceptibility mapping; IPH = intraplaque hemorrhage; T1W = T1-weighed; 3D = three-dimensional; CEA = carotid endarterectomy; RSI = relative signal intensity; RA = relative area.

    DOI: 10.3174/ajnr.A8356

    PubMed

    researchmap

  • Using Phase Difference Information to Detect Errors in the Flip Angle Measured with Actual Flip Angle Imaging at 7T.

    Tsuyoshi Matsuda, Yuji Iwadate, Futoshi Mori, Kota Takeda, Makoto Sasaki

    Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine   2022.11

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Flip angle (FA) measurements using the actual flip angle imaging (AFI) method may induce significant errors in ultrahigh fields. We aimed to develop a method for detecting errors in FA measurements using phase information at 7 tesla. We performed computer simulations to elucidate the relationship between the FA calculation errors and the phase difference between the two AFI source images. We then examined whether a method based on the phase difference could detect FA calculation errors and determine the prescribed nominal FA of the scanner for accurate measurements in phantoms and healthy volunteers. The simulations confirmed that the calculated FA values erroneously decreased when the longitudinal magnetization and phase in one of the source images were inverted. Tests on phantoms and human subjects demonstrated that the phase difference information between the source images with a cut-off of 90° could readily detect FA calculation errors in the AFI method.

    DOI: 10.2463/mrms.tn.2022-0053

    PubMed

    researchmap

  • Assessment of Heating on Titanium Alloy Cerebral Aneurysm Clips during 7T MRI

    S. Tsutsui, T. Matsuda, K. Takeda, M. Sasaki, Y. Kubo, K. Setta, S. Fujiwara, K. Chida, K. Ogasawara

    American Journal of Neuroradiology   43 ( 7 )   972 - 977   2022.7

     More details

    Publishing type:Research paper (scientific journal)   Publisher:American Society of Neuroradiology ({ASNR})  

    DOI: 10.3174/ajnr.A7561

    researchmap

  • GlyCEST: Magnetic Resonance Imaging of Glycine—Distribution in the Normal Murine Brain and Alterations in 5xFAD Mice

    Ken Ohno, Masaki Ohkubo, Bingwen Zheng, Masaki Watanabe, Tsuyoshi Matsuda, Ingrid L. Kwee, Hironaka Igarashi

    Contrast Media & Molecular Imaging   2021   1 - 8   2021.12

     More details

    Publishing type:Research paper (scientific journal)   Publisher:Hindawi Limited  

    The glycine level in the brain is known to be altered in neuropsychiatric disorders, such as schizophrenia and Alzheimer’s disease (AD). Several studies have reported the in vivo measurement of glycine concentrations in the brain using proton magnetic resonance spectroscopy (1H-MRS), but 1H-MRS is not capable of imaging the distribution of glycine concentration with high spatial resolution. Chemical exchange saturation transfer magnetic resonance imaging (CEST-MRI) is a new technology that can detect specific molecules, including amino acids, in tissues. To validate the measurements of glycine concentrations in living tissues using CEST from glycine to water (GlyCEST), we extracted the brain tissues from mice and performed biochemical tests. In wild-type C57BL/6 mice, GlyCEST effects were found to be higher in the thalamus than in the cerebral cortex (<inline-formula>
    <math xmlns="http://www.w3.org/1998/Math/MathML" id="M1">
    <mi>P</mi>
    <mo>&lt;</mo>
    <mn>0.0001</mn>
    </math>
    </inline-formula>, paired t-test), and this result was in good agreement with the biochemical results. In 5xFAD mice, an animal model of AD, GlyCEST measurements demonstrated that glycine concentrations in the cerebral cortex (<inline-formula>
    <math xmlns="http://www.w3.org/1998/Math/MathML" id="M2">
    <mi>P</mi>
    <mo>&lt;</mo>
    <mn>0.05</mn>
    </math>
    </inline-formula>, unpaired t-test) and thalamus (<inline-formula>
    <math xmlns="http://www.w3.org/1998/Math/MathML" id="M3">
    <mi>P</mi>
    <mo>&lt;</mo>
    <mn>0.0001</mn>
    </math>
    </inline-formula>, unpaired t-test), but not in the hippocampus, were decreased compared to those in wild-type mice. These findings suggest that we have successfully applied the CEST-MRI technique to map the distribution of glycine concentrations in the murine brain. The present method also captured the changes in cerebral glycine concentrations in mice with AD. Imaging the distribution of glycine concentrations in the brain can be useful in investigating and elucidating the pathological mechanisms of neuropsychiatric disorders.

    DOI: 10.1155/2021/8988762

    researchmap

    Other Link: http://downloads.hindawi.com/journals/cmmi/2021/8988762.xml

  • Assessment of Impaired Cerebrovascular Reactivity in Chronic Cerebral Ischemia using Intravoxel Incoherent Motion Magnetic Resonance Imaging. International journal

    Ikuko Uwano, Masakazu Kobayashi, Kengo Setta, Kuniaki Ogasawara, Fumio Yamashita, Futoshi Mori, Tsuyoshi Matsuda, Makoto Sasaki

    Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association   30 ( 12 )   106107 - 106107   2021.12

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    BACKGROUND: The severity of chronic cerebral ischemia can be assessed using cerebrovascular reactivity (CVR) to acetazolamide (ACZ) challenge, which is measured by single-photon emission computed tomography (SPECT); however, this is an invasive method. We investigated whether intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) can assess impaired CVR in preoperative patients with chronic cerebral ischemia and compared it to SPECT-CVR. METHODS: Forty-seven patients with unilateral cervical carotid artery stenosis underwent diffusion-weighted MRI with 11 b-values in the range of 0-800 s/mm2 and cerebral perfusion SPECT with the ACZ challenge. The perfusion fraction (f) and diffusion coefficient (D) of the IVIM parameters were calculated using a bi-exponential model. The f and D values and these ratios of the ipsilateral middle cerebral artery territory against the contralateral side were compared with the CVR values of the affected side calculated from the SPECT data. RESULTS: The IVIM-f and D values in the affected side were significantly higher than those in the unaffected side (median: 7.74% vs. 7.45%, p = 0.027; 0.816 vs. 0.801 10-3mm2/s, p < 0.001; respectively). However, there were no significant correlations between the f or D values and SPECT-CVR values in the affected side. In contrast, the f ratio showed a moderate negative correlation with the SPECT-CVR values (r = -0.40, p = 0.006) and detected impaired CVR (< 18.4%) with a sensitivity/specificity of 0.71/0.90. CONCLUSION: The IVIM perfusion parameter, f, can noninvasively assess impaired CVR with high sensitivity and specificity in patients with unilateral cervical carotid artery stenosis.

    DOI: 10.1016/j.jstrokecerebrovasdis.2021.106107

    PubMed

    researchmap

  • グリシンCEST-MRイメージング法の開発とアルツハイマー病モデルマウスへの応用

    大野 健, 計良 妙, 大久保 真樹, 渡辺 将樹, 松田 豪, 五十嵐 博中

    脳循環代謝   33 ( 1 )   119 - 119   2021.11

     More details

    Language:Japanese   Publisher:(一社)日本脳循環代謝学会  

    researchmap

  • 成人虚血発症もやもや病におけるMRI Hadamard ASLを用いた脳循環不全の検出

    攝田 典悟, 松田 豪, 佐々木 真理, 千葉 貴之, 藤原 俊朗, 小林 正和, 吉田 研二, 久保 慶高, 鈴木 美知子, 吉岡 邦浩, 小笠原 邦昭

    脳循環代謝   33 ( 1 )   91 - 91   2021.11

     More details

    Language:Japanese   Publisher:(一社)日本脳循環代謝学会  

    researchmap

  • Separating spin compartments in arterial spin labeling using delays alternating with nutation for tailored excitation (DANTE) pulse: A validation study using T2 -relaxometry and application to arterial cerebral blood volume imaging. International journal

    Shota Ishida, Hirohiko Kimura, Naoyuki Takei, Yasuhiro Fujiwara, Tsuyoshi Matsuda, Masayuki Kanamoto, Yuki Matta, Nobuyuki Kosaka, Eiji Kidoya

    Magnetic resonance in medicine   87 ( 3 )   1329 - 1345   2021.10

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    PURPOSE: To clarify the type of spin compartment in arterial spin labeling (ASL) that is eliminated by delays alternating with nutation for tailored excitation (DANTE) pulse using T2 -relaxometry, and to demonstrate the feasibility of arterial cerebral blood volume (CBVa ) imaging using DANTE-ASL in combination with a simplified two-compartment model. METHOD: The DANTE and T2 -preparation modules were combined into a single ASL sequence. T2 values under the application of DANTE were determined to evaluate changes in T2 , along with the post-labeling delay (PLD) and the relationship between transit time without DANTE (TTnoVS ) and T2 . The reference tissue T2 (T2_ref ) was also obtained. Subsequently, the DANTE module was embedded into the Hadamard-encoded ASL. Cerebral blood flow (CBF) and CBVa were computed using two Hadamard-encoding datasets (with and without DANTE) in a rest and breath-holding (BH) task. RESULTS: While T2 without DANTE (T2_noVS ) decreased as the PLD increased, T2 with DANTE (T2_DANTE ) was equivalent to T2_ref and did not change with the PLD. Although there was a significant positive correlation between TTnoVS and T2_noVS with short PLD, T2_DANTE was not correlated with TTnoVS nor PLD. Baseline CBVa values obtained at rest were 0.64 ± 0.12, 0.64 ± 0.11, and 0.58 ± 0.15 mL/100 g for anterior, middle, and posterior cerebral arteries, respectively. Significant CBF and CBVa elevations were observed in the BH task. CONCLUSION: Microvascular compartment signals were eliminated from the total ASL signals by DANTE. CBVa can be measured using Hadamard-encoded DANTE-ASL in combination with a simplified two-compartment model.

    DOI: 10.1002/mrm.29052

    PubMed

    researchmap

  • Diagnostic Accuracy of Screening Arterial Spin-Labeling MRI Using Hadamard Encoding for the Detection of Reduced CBF in Adult Patients with Ischemic Moyamoya Disease

    K. Setta, T. Matsuda, M. Sasaki, T. Chiba, S. Fujiwara, M. Kobayashi, K. Yoshida, Y. Kubo, M. Suzuki, K. Yoshioka, K. Ogasawara

    American Journal of Neuroradiology   42 ( 8 )   1403 - 1409   2021.8

     More details

    Publishing type:Research paper (scientific journal)   Publisher:American Society of Neuroradiology ({ASNR})  

    DOI: 10.3174/ajnr.A7167

    researchmap

  • Spatial and temporal variations of flip-angle distributions in the human brain using an eight-channel parallel transmission system at 7T: comparison of three radiofrequency excitation methods.

    Tsuyoshi Matsuda, Ikuko Uwano, Yuji Iwadate, Kunihiro Yoshioka, Makoto Sasaki

    Radiological physics and technology   14 ( 2 )   161 - 166   2021.6

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    We investigated the spatial and temporal variations of flip-angle (FA) distributions in the human brain from multiple scans, using an eight-channel parallel transmission (pTx) system at 7T. Nine healthy volunteers were scanned in five sessions using three radiofrequency excitation techniques each time: circular polarization (CP), static pTx, and dynamic pTx. We calculated the coefficients of variation of the FA values within the brain area to evaluate the variations, and the maximum intersession differences in the FA values (Dmax), comparing them between the three methods. The coefficients of variation decreased in the following order: CP, static pTx, and dynamic pTx (median: 20.1%, 13.6%, and 5.7%, respectively; p < 0.001). The average Dmax values were significantly higher for the static pTx (5.4°) than for the dynamic pTx (2.8°) and CP (1.7°) methods (p = 0.004 and 0.001, respectively). Compared to the CP method, the dynamic pTx method at 7T can efficiently minimize spatial variations in the FA distribution with a mild increase in temporal variations. The static pTx method exhibited a remarkably wide temporal variation.

    DOI: 10.1007/s12194-021-00612-8

    PubMed

    researchmap

  • Detection of impaired cerebrovascular reactivity in patients with chronic cerebral ischemia using whole-brain 7T MRA. Reviewed International journal

    Ikuko Uwano, Hiroyuki Kameda, Taisuke Harada, Masakazu Kobayashi, Wataru Yanagihara, Kengo Setta, Kuniaki Ogasawara, Kunihiro Yoshioka, Fumio Yamashita, Futoshi Mori, Tsuyoshi Matsuda, Makoto Sasaki

    Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association   29 ( 9 )   105081 - 105081   2020.9

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    BACKGROUND: Cerebrovascular reactivity (CVR) to acetazolamide (ACZ) on single-photon emission computed tomography (SPECT) can be used to assess the severity of chronic cerebral ischemia; however, this is an invasive method. We examined whether whole-brain magnetic resonance angiography (MRA) at 7T could non-invasively detect impaired CVR in patients with chronic cerebral ischemia by demonstrating the leptomeningeal collaterals (LMCs). METHODS: Fifty-seven patients with symptomatic unilateral cervical stenosis underwent whole-brain time-of-flight MRA at 7T and cerebral perfusion SPECT before/after the ACZ challenge. MRA images were visually assessed based on 6-point grading systems to evaluate the development of LMCs toward the middle cerebral artery (MCA) and antegrade flow of MCA. CVR of the affected side was calculated from the SPECT data. Subsequently, we compared the LMC grades on MRA with CVR on SPECT. RESULTS: CVR was significantly lower in grades ≥ 2 of LMCs than in grades 0-1 (P < 0.05) when applying LMCs from the anterior cerebral artery (ACA) and/or posterior cerebral artery (PCA). These differences were more evident than those in the grading of the antegrade MCA flow. The LMC grades from ACA/PCA readily detected reduced CVR (< 18.4%) with a sensitivity/specificity of 0.79/0.82. CONCLUSION: The development of LMCs on whole-brain MRA at 7T can non-invasively detect reduced CVR with a high sensitivity/specificity in patients with unilateral cervical stenosis.

    DOI: 10.1016/j.jstrokecerebrovasdis.2020.105081

    PubMed

    researchmap

  • Robust arterial transit time and cerebral blood flow estimation using combined acquisition of Hadamard‐encoded multi‐delay and long‐labeled long‐delay pseudo‐continuous arterial spin labeling: a simulation and in vivo study Reviewed

    Shota Ishida, Hirohiko Kimura, Makoto Isozaki, Naoyuki Takei, Yasuhiro Fujiwara, Masayuki Kanamoto, Nobuyuki Kosaka, Tsuyoshi Matsuda, Eiji Kidoya

    NMR in Biomedicine   33 ( 8 )   2020.8

     More details

    Publishing type:Research paper (scientific journal)   Publisher:Wiley  

    DOI: 10.1002/nbm.4319

    researchmap

    Other Link: https://onlinelibrary.wiley.com/doi/full-xml/10.1002/nbm.4319

  • Differentiation Between Multiple System Atrophy and Other Spinocerebellar Degenerations Using Diffusion Kurtosis Imaging. Reviewed International journal

    Kenji Ito, Chigumi Ohtsuka, Kunihiro Yoshioka, Tetsuya Maeda, Suguru Yokosawa, Futoshi Mori, Tsuyoshi Matsuda, Yasuo Terayama, Makoto Sasaki

    Academic radiology   26 ( 11 )   e333-e339   2019.11

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    RATIONALE AND OBJECTIVE: Differentiation between multiple system atrophy (MSA) and other spinocerebellar degenerations showing cerebellar ataxia is often difficult. Hence, we investigated whether magnetic resonance diffusion kurtosis imaging (DKI) could detect pathological changes that occur in these patients and be used for differential diagnosis. METHODS: Thirty-six subjects (12 patients with MSA accompanied by predominant cerebellar ataxia [MSA-C], 10 patients with spinocerebellar ataxias [SCAs] or sporadic adult-onset ataxia of unknown etiology [SAOA], and 14 healthy controls) were examined using 1.5- or 3-T magnetic resonance scanners. From the DKI data, the mean kurtosis, fractional anisotropy, and mean diffusivity values of the pontine crossing tract (PCT), middle cerebellar peduncle, and cerebellum were automatically measured, and the ratios against the values of the corpus callosum were calculated. RESULTS: We found significant decreases in mean kurtosis and fractional anisotropy ratios in the PCT and middle cerebellar peduncle, and a significant increase in the mean diffusivity ratio in the PCT in the MSA-C group, as compared with the SCA/SAOA and control groups (p < 0.027-0.001). Among these metrics, there were no significant differences in the diagnostic performance. By contrast, the ratios in the cerebellum showed no significant differences between the MSA-C and SCA/SAOA groups but were significantly altered when compared with the controls (p < 0.001). CONCLUSION: Quantitative DKI analyses can be used to differentiate between patients with MSA-C and those with SCA/SAOA.

    DOI: 10.1016/j.acra.2018.12.015

    PubMed

    researchmap

  • Intravascular signal suppression and microvascular signal mapping using delays alternating with nutation for tailored excitation (DANTE) pulse for arterial spin labeling perfusion imaging. Reviewed International journal

    Yasuhiro Fujiwara, Hirohiko Kimura, Shota Ishida, Masayuki Kanamoto, Naoyuki Takei, Tsuyoshi Matsuda, Nobuyuki Kosaka, Toshiki Adachi

    Magma (New York, N.Y.)   33 ( 3 )   367 - 376   2019.10

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    OBJECTIVE: To optimize the delays alternating with nutation for tailored excitation (DANTE) pulse as a vascular crushing gradient to eliminate macro-and micro-vascular signals and to generate a macrovascular space-related map by applying DANTE with multiple conditions. MATERIALS AND METHODS: Numerical simulation was performed to estimate the optimal flip angle (FA) of the DANTE. A phantom study was conducted to evaluate the impact of the FA and gradient area (GA) of the DANTE with three flow velocities and various parameters of the DANTE. Finally, an in vivo study was performed to assess the optimal DANTE parameters and to map the estimated macrovascular signal of the arterial spin labeling (ASL) signal. RESULTS: Numerical simulation revealed that the decrease of magnetization plateaued at 12.5° of FA. The phantom study showed that the setting of larger FA or GA decreased the ASL signals. The decrease of the ASL signal depended on the flow velocity, and the dependence increased with decreasing GA. The in vivo study revealed that larger FA and GA decreased the perfusion signal. DISCUSSION: An optimized DANTE makes it possible to efficiently suppress the macro-and-micro vascular signals depending on the flow velocity. Moreover, macrovascular signal mapping may be useful to assess altered hemodynamic states.

    DOI: 10.1007/s10334-019-00785-9

    PubMed

    researchmap

  • Appropriate echo time selection for quantitative susceptibility mapping. Reviewed

    Yuki Kanazawa, Yuki Matsumoto, Masafumi Harada, Hiroaki Hayashi, Tsuyoshi Matsuda, Hideki Otsuka

    Radiological physics and technology   12 ( 2 )   185 - 193   2019.6

     More details

    Language:English  

    The purpose of our study was to clarify the dependence of quantitative susceptibility mapping (QSM) on echo time (TE). We constructed a phantom consisting of six tubes; three tubes were filled with different concentrations (0.5, 1.0, and 2.5 mM) of gadopentetate dimeglumine (Gd-DTPA), and three were filled with different concentrations (100, 200, and 350 mg/mL) of calcium hydroxyapatite. Real and imaginary images from multi-echo spoiled gradient-echo data (12 echoes) were acquired. We then used four datasets with three serial echoes. The QSM procedure consists of four steps: field map estimation, phase unwrapping, background removal, and dipole inversion. For each sample, we compared the measured mean susceptibility value with the theoretical susceptibility value and conducted a linear regression analysis. Accordingly, the relationship between the measured susceptibility and concentration of Gd-DTPA was shown to agree well with the theoretical values (TEs = 16.4, 20.8, and 25.2 ms; slope = 0.24, R2 = 1.00). Furthermore, the relationship between the measured susceptibility and concentration of hydroxyapatite also showed good linearity (TEs = 16.4, 20.8, and 25.2 ms; slope = - 0.00121, R2 = 1.00). In conclusion, the optimization of the TE in QSM makes it possible to obtain more detailed information regarding the susceptibility of biomaterials.

    DOI: 10.1007/s12194-019-00513-x

    PubMed

    researchmap

  • Improvement of the repeatability of parallel transmission at 7T using interleaved acquisition in the calibration scan. Reviewed International journal

    Hiroyuki Kameda, Kohsuke Kudo, Tsuyoshi Matsuda, Taisuke Harada, Yuji Iwadate, Ikuko Uwano, Fumio Yamashita, Kunihiro Yoshioka, Makoto Sasaki, Hiroki Shirato

    Journal of magnetic resonance imaging : JMRI   48 ( 1 )   94 - 101   2018.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    BACKGROUND: Respiration-induced phase shift affects B0 /B1+ mapping repeatability in parallel transmission (pTx) calibration for 7T brain MRI, but is improved by breath-holding (BH). However, BH cannot be applied during long scans. PURPOSE: To examine whether interleaved acquisition during calibration scanning could improve pTx repeatability and image homogeneity. STUDY TYPE: Prospective. SUBJECTS: Nine healthy subjects. FIELD STRENGTH/SEQUENCE: 7T MRI with a two-channel RF transmission system was used. ASSESSMENT: Calibration scanning for B0 /B1+ mapping was performed under sequential acquisition/free-breathing (Seq-FB), Seq-BH, and interleaved acquisition/FB (Int-FB) conditions. The B0 map was calculated with two echo times, and the B1+ map was obtained using the Bloch-Siegert method. Actual flip-angle imaging (AFI) and gradient echo (GRE) imaging were performed using pTx and quadrature-Tx (qTx). All scans were acquired in five sessions. Repeatability was evaluated using intersession standard deviation (SD) or coefficient of variance (CV), and in-plane homogeneity was evaluated using in-plane CV. STATISTICAL TESTS: A paired t-test with Bonferroni correction for multiple comparisons was used. RESULTS: The intersession CV/SDs for the B0 /B1+ maps were significantly smaller in Int-FB than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The intersession CVs for the AFI and GRE images were also significantly smaller in Int-FB, Seq-BH, and qTx than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The in-plane CVs for the AFI and GRE images in Seq-FB, Int-FB, and Seq-BH were significantly smaller than in qTx (Bonferroni-corrected P < 0.01 for all). DATA CONCLUSION: Using interleaved acquisition during calibration scans of pTx for 7T brain MRI improved the repeatability of B0 /B1+ mapping, AFI, and GRE images, without BH. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.

    DOI: 10.1002/jmri.25903

    PubMed

    researchmap

  • Three-dimensional arterial spin labeling imaging with a DANTE preparation pulse Reviewed

    Tsuyoshi Matsuda, Hirohiko Kimura, Hiroyuki Kabasawa, Masayuki Kanamoto

    Magnetic Resonance Imaging   49   131 - 137   2018.6

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Elsevier Inc.  

    On arterial spin-labeled (ASL) images, areas of bright intravascular signal will appear when the post labeling delay time is shorter than arterial transit time. Vascular suppression (VS) schemes reduce artefactual bright signal by dephasing intravascular labeled spins. However, existing VS methods, such as Motion-Sensitized Driven-Equilibrium (MSDE), decrease the uniformity of the signal intensity distribution and extend the echo time. The purpose of this study is to compare VS using a Delays Alternating with Nutation for Tailored Excitation (DANTE) preparation pulse, with MSDE for ASL imaging on a flow phantom and volunteer data. In the phantom study, the signal decay pattern of moving water was similar for both methods. In the volunteer study, the bright intravascular signal artifact was decreased by both methods. However right–left differences in signal intensity were smaller using DANTE-prepared ASL. The proposed DANTE-prepared ASL sequence has a vessel suppression effect while maintaining a uniform signal intensity distribution. This study indicates that DANTE is a potentially useful method for vessel suppression in ASL imaging.

    DOI: 10.1016/j.mri.2018.02.001

    Scopus

    researchmap

  • Evaluation of retained products of conception using pulsed continuous arterial spin-labeling MRI: clinical feasibility and initial results Reviewed

    Nobuyuki Kosaka, Yasuhiro Fujiwara, Tetsuji Kurokawa, Tsuyoshi Matsuda, Masayuki Kanamoto, Naoyuki Takei, Kenji Takata, Jin Takahashi, Yoshio Yoshida, Hirohiko Kimura

    Magnetic Resonance Materials in Physics, Biology and Medicine   31 ( 4 )   1 - 8   2018.3

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Springer Verlag  

    Objectives: We evaluated the vascularity of retained products of conception (RPOC) using arterial spin-labeling magnetic resonance imaging (ASL-MRI) to clarify the clinical feasibility of this approach. Materials and methods: A pulsed-continuous ASL sequence with echo-planar imaging (EPI) acquisitions was used. Ten consecutive patients with RPOC were enrolled. All ASL images were evaluated visually and semiquantitatively and compared with the findings of Doppler ultrasound (US) and dynamic contrast-enhanced MRI (DCE-MRI). Results: The technical success rate was 93.7% (15/16 scans). One failed case was excluded from the analysis. Six patients showed quite high signals over RPOC, while three patients showed no abnormal signals. Doppler US alone failed to detect the hypervascular area in two cases, and ASL-MRI alone failed in three. A significant linear correlation was found between semiquantitative values of ASL-MRI and DCE-MRI. All six patients showing high signals on ASL-MRI underwent follow-up MRI after therapy. High signals in five patients decreased visually and semiquantitatively, while one patient showed signal increases. Conclusion: Evaluation of RPOC using ASL-MRI was clinically feasible and response to therapy could be evaluated. However, the clinical advantages over conventional imaging remain unclear and need to be evaluated.

    DOI: 10.1007/s10334-018-0681-0

    Scopus

    PubMed

    researchmap

  • Magnetization and demagnetization of magnetic dental attachments in a 3-T MRI system Reviewed

    Norio Hayashi, Akio Ogura, Toshio Tsuchihashi, Daisuke Takahashi, Tsuyoshi Matsuda, Shinya Seino, Tsukasa Doi

    Radiological Physics and Technology   10 ( 3 )   294 - 300   2017.9

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Springer Tokyo  

    The purpose of this study was to evaluate the magnetization and demagnetization of magnetic dental attachments in a 3.0-T magnetic resonance imaging (MRI) scanner. A high-field-strength (3.0 T) MRI scanner (Achieva 3.0 T, Philips, Amsterdam, Netherlands) was used. Magnetic flux leakage was measured using a gaussmeter. To evaluate the magnetization and demagnetization of the magnetic assemblies and keepers caused by the moving in and out of the MRI scanner, the magnetic force of the attachments was measured before and after the table was moved in and out. Two settings were used wherein the magnetic assemblies and keepers were positioned on the table at angles of 0° or 90° with respect to the magnetic flux of the static magnetic field. The movement of the table was repeated 15 times. In addition, the retentive force of the magnetic dental attachments was measured after magnetic field exposure. The magnetic force of the magnetic attachments positioned at 0° decreased significantly after moving in and out of the MRI scanner (p &lt
     0.05). In contrast, the magnetic force of the magnetic attachments positioned at 90° was stable after the movement of the table. The magnetic force of the keepers placed at both 0° and 90° was slightly increased after the movement of the table. At 0°, the retentive force of the magnet-keeper combinations decreased when the magnetic assembly was exposed to the strong magnetic flux of the MRI scanner. Therefore, the removal of all removable magnetic dentures is recommended before an MRI examination.

    DOI: 10.1007/s12194-017-0399-0

    Scopus

    PubMed

    researchmap

  • Measurement of Arterial Transit Time and Renal Blood Flow Using Pseudocontinuous ASL MRI With Multiple Post-Labeling Delays: Feasibility, Reproducibility, and Variation Reviewed

    Dong Won Kim, Woo Hyun Shim, Seong Kuk Yoon, Jong Yeong Oh, Jeong Kon Kim, Hoesu Jung, Tsuyoshi Matsuda, Dongeun Kim

    JOURNAL OF MAGNETIC RESONANCE IMAGING   46 ( 3 )   813 - 819   2017.9

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:WILEY  

    Purpose: To evaluate the feasibility, reproducibility, and variation of renal perfusion and arterial transit time (ATT) using pseudocontinuous arterial spin labeling magnetic resonance imaging (PCASL MRI) in healthy volunteers.
    Materials and Methods: PCASL MRI at 3T was performed in 25 healthy volunteers on two different occasions. The ATT and ATT-corrected renal blood flow (ATT-cRBF) were calculated at four different post-labeling delay points (0.5, 1.0, 1.5, and 2.0 s) and evaluated for each kidney and subject. The intraclass correlation (ICC) and Bland-Altman plot were used to assess the reproducibility of the PCASL MRI technique. The within-subject coefficient of variance was determined.
    Results: Results were obtained for 46 kidneys of 23 subjects with a mean age of 38.6 +/- 9.8 years and estimated glomerular filtration rate (eGFR) of 89.1 +/- 21.2 ml/min/1.73m(2). Two subjects failed in the ASL MRI examination. The mean cortical and medullary ATT-cRBF for the subjects were 215 +/- 65 and 81 +/- 21 ml/min/100 g, respectively, and the mean cortical and medullary ATT were 1141 +/- 262 and 1123 +/- 245 msec, correspondingly. The ICC for the cortical ATT-cRBF was 0.927 and the within-subject coefficient of variance was 14.4%. The ICCs for the medullary ATT-cRBF and the cortical and medullary ATT were poor. The Bland-Altman plot for cortical RBF showed good agreement between the two measurements.
    Conclusion: PCASL MRI is a feasible and reproducible method for measuring renal cortical perfusion. In contrast, ATT for the renal cortex and medulla has poor reproducibility and high variation.

    DOI: 10.1002/jmri.25634

    Web of Science

    PubMed

    researchmap

  • Temporal brain metabolite changes in preterm infants with normal development. Reviewed International journal

    Sachiko Tanifuji, Manami Akasaka, Atsushi Kamei, Nami Araya, Maya Asami, Atsushi Matsumoto, Genichiro Sotodate, Yu Konishi, Satoko Shirasawa, Yukiko Toya, Syuji Kusano, Shoichi Chida, Makoto Sasaki, Tsuyoshi Matsuda

    Brain & development   39 ( 3 )   196 - 202   2017.3

     More details

    Language:English  

    OBJECTIVE: Preterm infants are at high risk for developmental delay, epilepsy, and autism spectrum disorders. Some reports have described associations between these conditions and gamma-aminobutyric acid (GABA) dysfunction; however, no study has evaluated temporal changes in GABA in preterm infants. Therefore, we assessed temporal changes in brain metabolites including GABA using single-voxel 3-Tesla (T) proton magnetic resonance spectroscopy (1H-MRS) in preterm infants with normal development. METHODS: We performed 3T 1H-MRS at 37-46 postmenstrual weeks (PMWs, period A) and 64-73PMWs (period B). GABA was assessed with the MEGA-PRESS method. N-acetyl aspartate (NAA), glutamate-glutamine complex (Glx), creatine (Cr), choline (Cho), and myo-inositol (Ins) were assessed with the PRESS method. Metabolite concentrations were automatically calculated using LCModel. RESULTS: Data were collected from 20 preterm infants for periods A and B (medians [ranges], 30 [24-34] gestational weeks, 1281 [486-2030]g birth weight). GABA/Cr ratio decreased significantly in period B (p=0.03), but there was no significant difference in GABA/Cho ratios (p=0.58) between the two periods. In period B, NAA/Cr, Glx/Cr, NAA/Cho, and Glx/Cho ratios were significantly increased (p<0.01), whereas Cho/Cr, Ins/Cr, and Ins/Cho ratios were significantly decreased (p<0.01). There was no significant difference for GABA or Cho concentrations (p=0.52, p=0.22, respectively). NAA, Glx, and Cr concentrations were significantly increased (p<0.01), whereas Ins was significantly decreased (p<0.01). CONCLUSIONS: Our results provide new information on normative values of brain metabolites in preterm infants.

    DOI: 10.1016/j.braindev.2016.10.006

    PubMed

    researchmap

  • Comparison of long-labeled pseudo-continuous arterial spin labeling (ASL) features between young and elderly adults: special reference to parameter selection Reviewed

    Yasuhiro Fujiwara, Tsuyoshi Matsuda, Masayuki Kanamoto, Tatsuro Tsuchida, Kazunobu Tsuji, Nobuyuki Kosaka, Toshiki Adachi, Hirohiko Kimura

    ACTA RADIOLOGICA   58 ( 1 )   84 - 90   2017.1

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:SAGE PUBLICATIONS LTD  

    Background The signal intensity obtained by arterial spin labeling (ASL) depends not only on perfusion signal, but also on arterial transit time (ATT). Although ATT has a more significant effect on accurate regional cerebral blood flow (CBF) calculations, the multiple post-labeling delay (PLD) approach is difficult to use in routine examinations.
    Purpose To optimize imaging parameters for labeling duration (LD) and PLD and to confirm their validity in long-labeled pseudo-continuous ASL.
    Material and Methods The perfusion signal was simulated in four LDs and theoretical signal-to-noise ratio efficiency (SNReff) was calculated. Invivo studies were performed on a 3.0T magnetic resonance imaging (MRI) scanner and 15 volunteers were categorized into either the young or elderly adult groups. We compared the differences in CBF values with or without ATT correction.
    Results Regarding signal simulation, perfusion signal increased with the length of LD. SNReff also improved with LD, but SNReff plateaued at an LD of 3.0s. As for the invivo study, SNR linearly increased along with the LD. The CBF differences with the correction of ATT were larger in the elderly adult group. This trend was most prominent in the longer ATT area in the occipital cortical region.
    Conclusion A combination of imaging settings of LD=3.5s and PLD=2.0s were suggested as optimal imaging parameters for allowing acceptable CBF quantification and sufficient SNR in both young and elderly individuals.

    DOI: 10.1177/0284185116632387

    Web of Science

    PubMed

    researchmap

  • MR Spectroscopy in Patients with Hereditary Diffuse Leukoencephalopathy with Spheroids and Asymptomatic Carriers of Colony-stimulating Factor 1 Receptor Mutation Reviewed

    Takashi Abe, Toshitaka Kawarai, Koji Fujita, Wataru Sako, Yuka Terasawa, Tsuyoshi Matsuda, Waka Sakai, Ai Tsukamoto-Miyashiro, Naoko Matsui, Yuishin Izumi, Ryuji Kaji, Masafumi Harada

    MAGNETIC RESONANCE IN MEDICAL SCIENCES   16 ( 4 )   297 - 303   2017

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JPN SOC MAGNETIC RESONANCE MEDICINE  

    Purpose: Hereditary diffuse leukoencephalopathy with spheroids (HDLS) is a rare neurodegenerative disorder with various clinical presentations. Mutation of the colony-stimulating factor 1 receptor (CSF1R) gene is considered to be a cause of this autosomal dominant disorder. The purpose of this study was to report magnetic resonance spectroscopy (MRS) findings in patients with HDLS and asymptomatic carriers and to clarify the use of MRS in this disease.
    Materials and Methods: In this retrospective, institutional review board-approved study, we included four consecutive patients, genetically diagnosed with HDLS, and two asymptomatic carriers after acquiring informed consent. We performed single-voxel MRS of the left centrum semiovale on a 3T clinical scanner. We also included a sex-matched normal dataset. We quantified N-acetylaspartate (NAA), creatine, choline-containing compounds (Cho), glutamine, glutamate (Glu), myo-inositol (Ins), glutathione, lactate (Lac), and gamma-amino butyric acid using LCModel. We performed statistical analysis, and P value &lt; 0.05 was considered significant.
    Results: In HDLS cases, MRS revealed decreased NAA and Glu concentrations, which probably reflected neuronal damage and/or loss, and a subsequent reduction of neurotransmitters. A patient with HDLS also had increased Cho and Ins concentrations, indicating gliosis, and increased Cho concentration was also observed in an asymptomatic carrier. This suggests that metabolic changes had already occurred in an asymptomatic state.
    Conclusion: We demonstrated changes in metabolite concentrations not only in patients with HDLS but also in asymptomatic CSF1R mutation carriers. Our study indicates that MRS is a potentially useful tool for the analysis of metabolic and pathophysiological findings of HDLS, even during the early stages of disease.

    DOI: 10.2463/mrms.mp.2016-0016

    Web of Science

    PubMed

    researchmap

  • Breath-holding during the Calibration Scan Improves the Reproducibility of Parallel Transmission at 7T for Human Brain Reviewed

    Taisuke Harada, Kohsuke Kudo, Ikuko Uwano, Fumio Yamashita, Hiroyuki Kameda, Tsuyoshi Matsuda, Makoto Sasaki, Hiroki Shirato

    MAGNETIC RESONANCE IN MEDICAL SCIENCES   16 ( 1 )   23 - 31   2017

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JPN SOC MAGNETIC RESONANCE IN MEDICINE  

    Purpose: The B0 and B1+ maps required for calculation of the radiofrequency (RF) pulse of parallel transmission (pTx) are obtained in calibration scans; however, they may be affected by respiratory motion. We aimed to compare the reproducibility of B0 and B1+ maps and gradient echo (GRE) images of the brain scanned with pTx at 7T between free-breathing (FB) and breath-holding (BH) conditions during the calibration scan.
    Methods: Nine healthy volunteers were scanned by 7T MRI using a two-channel quadrature head coil. In the pTx calibration scans performed with FB and BH, the B0 map was obtained from two different TE images and the B1+ map was calculated by the Bloch-Siegert method. A GRE image (gradient-recalled acquisition in steady state) was also obtained with RF shimming and RF design of pTx with spoke method, as well as quadrature transmission (qTx). All the scans were repeated over five sessions. The reproducibility of the B0 and B1+ maps and GRE image was evaluated with region-of-interest measurements using inter-session standard deviation (SD) and coefficient of variation (CV) values. Intensity homogeneity of GRE images was also assessed with in-plane CV.
    Results: Inter-session SDs of B0 and B1+ maps were significantly smaller in BH (P &lt; 0.01). Inter-session CVs of GRE images were significantly smaller in qTx than BH and FB (P &lt; 0.01, both); however, the CVs of BH were significantly smaller (P &lt; 0.01). In-plane CVs of FB and BH with RF shimming were not significantly different with qTx; however, CVs of FB and BH with RF design were significantly smaller than those of qTx (P &lt; 0.05 and P &lt; 0.01, respectively).
    Conclusion: BH could improve the reproducibility of B0 and B1+ maps in pTx calibration scans and GRE images. These results might facilitate the development of pTx in human brain at 7T.

    DOI: 10.2463/mrms.mp.2015-0137

    Web of Science

    PubMed

    researchmap

  • Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging Reviewed

    Kazuhiro Shimizu, Nobuyuki Kosaka, Yasuhiro Fujiwara, Tsuyoshi Matsuda, Tatsuya Yamamoto, Tatsuro Tsuchida, Katsuki Tsuchiyama, Nobuyuki Oyama, Hirohiko Kimura

    MAGNETIC RESONANCE IN MEDICAL SCIENCES   16 ( 1 )   38 - 44   2017

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JPN SOC MAGNETIC RESONANCE IN MEDICINE  

    Purpose: The importance of arterial transit time (ATT) correction for arterial spin labeling MRI has been well debated in neuroimaging, but it has not been well evaluated in renal imaging. The purpose of this study was to evaluate the feasibility of pulsed continuous arterial spin labeling (pcASL) MRI with multiple post-labeling delay (PLD) acquisition for measuring ATT-corrected renal blood flow (ATC-RBF).
    Materials and Methods: A total of 14 volunteers were categorized into younger (n = 8; mean age, 27.0 years) and older groups (n = 6; 64.8 years). Images of pcASL were obtained at three different PLDs (0.5, 1.0, and 1.5 s), and ATC-RBF and ATT were calculated using a single-compartment model. To validate ATC-RBF, a comparative study of effective renal plasma flow (ERPF) measured by 55mTc-MAG3 scintigraphy was performed. ATC-RBF was corrected by kidney volume (ATC-cRBF) for comparison with ERPF.
    Results: The younger group showed significantly higher ATC-RBF (157.68 +/- 38.37 mL/min/100 g) and shorter ATT (961.33 +/- 260.87 ms) than the older group (117.42 +/- 24.03 mL/min/100 g and 1227.94 +/- 226.51 ms, respectively; P &lt; 0.05). A significant correlation was evident between ATC-cRBF and ERPF (P &lt; 0.05, r = 0.47). With suboptimal single PLD (1.5 s) settings, there was no significant correlation between ERPF and kidney volume-corrected RBF calculated from single PLD data.
    Conclusion: Calculation of ATT and ATC-RBF by pcASL with multiple PLD was feasible in healthy volunteers, and differences in ATT and ATC-RBF were seen between the younger and older groups. Although ATT correction by multiple PLD acquisitions may not always be necessary for RBF quantification in the healthy subjects, the effect of ATT should be taken into account in renal ASL-MRI as debated in brain imaging.

    DOI: 10.2463/mrms.mp.2015-0117

    Web of Science

    PubMed

    researchmap

  • MR spectroscopy in patients with hereditary diffuse leukoencephalopathy with spheroids and asymptomatic carriers of colony-stimulating factor 1 receptor mutation Reviewed

    Takashi Abe, Toshitaka Kawarai, Koji Fujita, Wataru Sako, Yuka Terasawa, Tsuyoshi Matsuda, Waka Sakai, Ai Tsukamoto-Miyashiro, Naoko Matsui, Yuishin Izumi, Ryuji Kaji, Masafumi Harada

    Magnetic Resonance in Medical Sciences   16 ( 4 )   297 - 303   2017

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Japanese Society for Magnetic Resonance in Medicine  

    Purpose: Hereditary diffuse leukoencephalopathy with spheroids (HDLS) is a rare neurodegenerative disorder with various clinical presentations. Mutation of the colony-stimulating factor 1 receptor (CSF1R) gene is considered to be a cause of this autosomal dominant disorder. The purpose of this study was to report magnetic resonance spectroscopy (MRS) findings in patients with HDLS and asymptomatic carriers and to clarify the use of MRS in this disease. Materials and Methods: In this retrospective, institutional review board-approved study, we included four consecutive patients, genetically diagnosed with HDLS, and two asymptomatic carriers after acquiring informed consent. We performed single-voxel MRS of the left centrum semiovale on a 3T clinical scanner. We also included a sex-matched normal dataset. We quantified N-acetylaspartate (NAA), creatine, choline-containing compounds (Cho), glutamine, glutamate (Glu), myo-inositol (Ins), glutathione, lactate (Lac), and gamma-amino butyric acid using LCModel. We performed statistical analysis, and P value &lt
    0.05 was considered significant. Results: In HDLS cases, MRS revealed decreased NAA and Glu concentrations, which probably reflected neuronal damage and/or loss, and a subsequent reduction of neurotransmitters. A patient with HDLS also had increased Cho and Ins concentrations, indicating gliosis, and increased Cho concentration was also observed in an asymptomatic carrier. This suggests that metabolic changes had already occurred in an asymptomatic state. Conclusion: We demonstrated changes in metabolite concentrations not only in patients with HDLS but also in asymptomatic CSF1R mutation carriers. Our study indicates that MRS is a potentially useful tool for the analysis of metabolic and pathophysiological findings of HDLS, even during the early stages of disease.

    DOI: 10.2463/mrms.mp.2016-0016

    Scopus

    PubMed

    researchmap

  • Relation between brain temperature and white matter damage in subacute carbon monoxide poisoning. Reviewed International journal

    Shunrou Fujiwara, Yoshichika Yoshioka, Tsuyoshi Matsuda, Hideaki Nishimoto, Akira Ogawa, Kuniaki Ogasawara, Takaaki Beppu

    Scientific reports   6   36523 - 36523   2016.11

     More details

    Language:English  

    In the previous studies, carbon monoxide (CO) poisoning showed an imbalance between cerebral perfusion and metabolism in the acute phase and the brain temperature (BT) in these patients remained abnormally high from the acute to the subacute phase. As observed in chronic ischemic patients, BT can continuously remain high depending on impairments of cerebral blood flow and metabolism; this is because heat removal and production system in the brain may mainly be maintained by the balance of these two factors; thus, cerebral white matter damage (WMD) affecting normal metabolism may affect the BT in patients with CO poisoning. Here, we investigated whether the BT correlates with the degree of WMD in patients with subacute CO-poisoning. In 16 patients with subacute CO-poisoning, the BT and degree of WMD were quantitatively measured by using magnetic resonance spectroscopy and the fractional anisotropy (FA) value from diffusion tensor imaging dataset. Consequently, the BT significantly correlated with the degree of WMD. In particular, BT observed in patients with delayed neuropsychiatric sequelae, a crucial symptom with sudden-onset in the chronic phase after CO exposure, might indicate cerebral hypo-metabolism and abnormal hemodynamics like "matched perfusion," in which the reduced perfusion matches the reduced metabolism.

    DOI: 10.1038/srep36523

    PubMed

    researchmap

  • The Safety of MR Conditional Cochlear Implant at 1.5 Tesla Magnetic Resonance Imaging System. Reviewed

    Takahashi D, Ogura A, Hayashi N, Seino S, Kawai R, Matsuda T, Doi T, Tsuchihashi T

    Nihon Hoshasen Gijutsu Gakkai zasshi   72 ( 8 )   674 - 680   2016.8

  • Simple noise reduction for diffusion weighted images Reviewed

    Yuto Konishi, Yuki Kanazawa, Takatoshi Usuda, Yuki Matsumoto, Hiroaki Hayashi, Tsuyoshi Matsuda, Junji Ueno, Masafumi Harada

    Radiological Physics and Technology   9 ( 2 )   221 - 226   2016.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Springer Tokyo  

    Our purpose in this study was to reduce the noise in order to improve the SNR of Dw images with high b-value by using two correction schemes. This study was performed with use of phantoms made from water and sucrose at different concentrations, which were 10, 30, and 50 weight percent (wt%). In noise reduction for Dw imaging of the phantoms, we compared two correction schemes that are based on the Rician distribution and the Gaussian distribution. The highest error values for each concentration with use of the Rician distribution scheme were 7.3 % for 10 wt%, 2.4 % for 30 wt%, and 0.1 % for 50 wt%. The highest error values for each concentration with use of the Gaussian distribution scheme were 20.3 % for 10 wt%, 11.6 % for 30 wt%, and 3.4 % for 50 wt%. In Dw imaging, the noise reduction makes it possible to apply the correction scheme of Rician distribution.

    DOI: 10.1007/s12194-016-0350-9

    Scopus

    PubMed

    researchmap

  • Arterial Transit Time Mapping Obtained by Pulsed Continuous 3D ASL Imaging with Multiple Post-Label Delay Acquisitions: Comparative Study with PET-CBF in Patients with Chronic Occlusive Cerebrovascular Disease (vol 11, e0156005, 2016) Reviewed

    Tsujikawa T, Kimura H, Matsuda T, Fujiwara Y, Isozaki M, Kikuta K, Okazawa H

    PLOS ONE   11 ( 7 )   e0156005   2016.7

     More details

    Language:English   Publisher:PUBLIC LIBRARY SCIENCE  

    DOI: 10.1371/journal.pone.0159894

    Web of Science

    PubMed

    researchmap

  • Arterial Transit Time Mapping Obtained by Pulsed Continuous 3D ASL Imaging with Multiple Post-Label Delay Acquisitions: Comparative Study with PET-CBF in Patients with Chronic Occlusive Cerebrovascular Disease Reviewed

    Tetsuya Tsujikawa, Hirohiko Kimura, Tsuyoshi Matsuda, Yasuhiro Fujiwara, Makoto Isozaki, Ken-ichiro Kikuta, Hidehiko Okazawa

    PLOS ONE   11 ( 6 )   2016.6

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:PUBLIC LIBRARY SCIENCE  

    Arterial transit time (ATT) is most crucial for measuring absolute cerebral blood flow (CBF) by arterial spin labeling (ASL), a noninvasive magnetic resonance (MR) perfusion assessment technique, in patients with chronic occlusive cerebrovascular disease. We validated ASL-CBF and ASL-ATT maps calculated by pulsed continuous ASL (pCASL) with multiple post-label delay acquisitions in patients with occlusive cerebrovascular disease. Fifteen patients underwent MR scans, including pCASL, and positron emission tomography (PET) scans with O-15-water to obtain PET-CBF. MR acquisitions with different post-label delays (1.0, 1.5, 2.0, 2.5 and 3.0 sec) were also obtained for ATT correction. The theoretical framework of 2-compartmental model (2CM) was also used for the delay compensation. ASL-CBF and ASL-ATT were calculated based on the proposed 2CM, and the effect on the CBF values and the ATT correction characteristics were discussed. Linear regression analyses were performed both on pixel-by-pixel and region-of-interest bases in the middle cerebral artery (MCA) territory. There were significant correlations between ASL-CBF and PET-CBF both for voxel values (r = 0.74 +/- 0.08, slope: 0.87 +/- 0.22, intercept: 6.1 +/- 4.9) and for the MCA territorial comparison in both affected (R-2 = 0.67, y = 0.83x + 6.3) and contralateral sides (R-2 = 0.66, y = 0.74x + 6.3). ASL-ATTs in the affected side were significantly longer than those in the contralateral side (1.51 +/- 0.41 sec and 1.12 +/- 0.30 sec, respectively, p &lt; 0.0005). CBF measurement using pCASL with delay compensation was feasible and fairly accurate even in altered hemodynamic states.

    DOI: 10.1371/journal.pone.0156005

    Web of Science

    researchmap

  • Brain temperature measured by 1H-magnetic resonance spectroscopy in acute and subacute carbon monoxide poisoning. Reviewed International journal

    Shunrou Fujiwara, Yoshichika Yoshioka, Tsuyoshi Matsuda, Hideaki Nishimoto, Toshiyuki Murakami, Akira Ogawa, Kuniaki Ogasawara, Takaaki Beppu

    Neuroradiology   58 ( 1 )   27 - 32   2016.1

     More details

    Language:English  

    INTRODUCTION: Brain temperature (BT) is associated with the balance between cerebral blood flow and metabolism according to the "heat-removal" theory. The present study investigated whether BT is abnormally altered in acute and subacute CO-poisoned patients by using (1)H-magnetic resonance spectroscopy (MRS). METHODS: Eight adult CO-poisoned patients underwent 3-T magnetic resonance imaging in the acute and subacute phases after CO exposure. MRS was performed on deep cerebral white matter in the centrum semiovale, and MRS-based BT was estimated by the chemical shift difference between water and the N-acetyl aspartate signal. We defined the mean BT + 1.96 standard deviations of the BT in 15 healthy controls as the cutoff value for abnormal BT increases (p < 0.05) in CO-poisoned patients. RESULTS: BT of CO-poisoned patients in both the acute and subacute phases was significantly higher than that of the healthy control group. However, BT in the subacute phase was significantly lower than in the acute phase. On the other hand, no significant difference in body temperature was observed between acute and subacute CO-poisoned patients. BT weakly correlated with body temperature, but this correlation was not statistically significant (rho = 0.304, p = 0.2909). CONCLUSIONS: The present results suggest that BT in CO-poisoned patients is abnormally high in the acute phase and remains abnormal in the subacute phase. BT alteration in these patients may be associated with brain perfusion and metabolism rather than other factors such as systemic inflammation and body temperature.

    DOI: 10.1007/s00234-015-1600-y

    PubMed

    researchmap

  • Noise estimation for diffusion weighted MR image Reviewed

    Yuki Kanazawa, Konishi Yuto, Usuda Takatoshi, Yuki Matsumoto, Hiroaki Hayashi, Matsuda Tsuyoshi, Masafumi Harada

    European Congress of Radiology   C-0591   2016

     More details

    Language:English   Publishing type:Research paper (international conference proceedings)  

    researchmap

  • Simple improvement method of uniformity of MR elastography on liver Reviewed

    Yuki Kanazawa, Yuki Matsumoto, Hiroaki Hayashi, Tsuyoshi Matsuda, Munguu Ganbold, Masafumi Harada

    Proceedings of the 24th Annual Meeting of ISMRM   2972   2016

     More details

    Language:English   Publishing type:Research paper (international conference proceedings)  

    researchmap

  • Comparison with statistical analysis of signal correction in diffusion weighted MR image Reviewed

    Yuto Konishi, Yuki Kanazawa, Takatoshi Usuda, Yuki Matsumoto, Hiroaki Hayashi, Tsuyoshi Matsuda, Masafumi Harada

    European Congress of Radiology   C-0291   2016

     More details

    Language:English   Publishing type:Research paper (international conference proceedings)  

    researchmap

  • Operator-bias-free Comparison of Quantitative Perfusion Maps Acquired with Pulsed-continuous Arterial Spin Labeling and Single-photon-emission Computed Tomography Reviewed

    Takashi Iwanaga, Masafumi Harada, Hitoshi Kubo, Yasuhiro Funakoshi, Yamato Kunikane, Tsuyoshi Matsuda

    MAGNETIC RESONANCE IN MEDICAL SCIENCES   13 ( 4 )   239 - 249   2014

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JPN SOC MAGNETIC RESONANCE IN MEDICINE  

    Purpose: We compared the regional cerebral blood flow (rCBF) obtained by pulsed continuous arterial spin labeling (pCASL) and iodine-123-N-isopropyl-p-iodoamphetamine (IMP) single photon emission computed tomography (SPECT) using 3-dimensional stereotactic region-of-interest (ROT) software for automated definition of ROIs in anatomic regions of the brain.
    Methods: Thirteen patients with cerebrovascular occlusive disease and three with transient ischemic attacks underwent pCASL and IMP SPECT imaging. We compared rCBF values of each anatomic region and calculated the correlation coefficients between pCASL and IMP SPECT. We also calculated the asymmetry index (AI) using ROIs in contralateral regions of the hemispheres.
    Results: The rCBF values calculated from pCASL and IMP SPECT were comparable in most segments, but rCBF in the thalamus (P &lt; 0.0001) and hippocampus (P = 0.0006) was significantly higher measured by pCASL than IMP SPECT. The correlation of rCBF between pCASL and IMP SPECT in the affected hemisphere (r = 0.50) tended to be lower than that in the normal hemisphere (r = 0.59), but not significantly different (P = 0.25). Moreover, there was a fixed bias for underestimation of rCBF by pCASL (P = 0.0047) in the affected hemisphere. The calculated AT showed a significant relationship between methods (r = 0.79, P &lt; 0.0001).
    Conclusion: The rCBF obtained by pCASL had positive relationships with IMP SPECT. However, it should be considered that pCASL tends to have a weak relationship with IMP SPECT in some normal regions and regions affected by cerebrovascular occlusive disease.

    DOI: 10.2463/mrms.2013-0117

    Web of Science

    PubMed

    researchmap

  • Noninvasive measurement of human brain temperature adjacent to arteriovenous malformation using 3.0 T magnetic resonance spectroscopy Reviewed

    Takashi Inoue, Hiroaki Shimizu, Miki Fujimura, Atsushi Saito, Yoshichika Yoshioka, Tsuyoshi Matsuda, Teiji Tominaga

    CLINICAL NEUROLOGY AND NEUROSURGERY   115 ( 4 )   445 - 449   2013.4

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:ELSEVIER SCIENCE BV  

    Object: The brain temperature at rest is determined by the balance between heat produced by cerebral energy turnover, which is identical to cerebral metabolism, and heat that is removed, primarily by cerebral blood flow. The present study investigated whether brain temperature measured by proton magnetic resonance (MR) spectroscopy can detect cerebral hemodynamic impairment in patients with arteriovenous malformations (AVMs) as shown by single photon emission computed tomography (SPECT).
    Methods: Brain temperature, cerebral blood flow, and cerebrovascular reactivity were measured using proton MR spectroscopy and SPECT in five healthy volunteers and six patients with AVMs. Regions of interest were selected adjacent to the AVMs and in the corresponding contralateral region.
    Results: Brain temperature around AVMs was calculated in all subjects using MR spectroscopy. The mean brain temperature in volunteers was 37.1 +/- 0.41 degrees C. A significant correlation was observed between brain temperature ratio (affected side/contralateral side) and cerebrovascular reactivity ratio (affected side/contralateral side) (r = -0.82, p = 0.0480).
    Conclusion: Brain temperature measured by proton MR spectroscopy can detect cerebral hemodynamic impairment in patients with AVMs. Further investigations regarding the relationships between brain temperature and clinical feature in patients with AVMs are needed. (c) 2012 Elsevier B.V. All rights reserved.

    DOI: 10.1016/j.clineuro.2012.06.022

    Web of Science

    PubMed

    researchmap

  • Prostate 3T-MR spectroscopic imaging without an endorectal surface coil using the MLEV-PRESS sequence Reviewed

    Takeshi Yoshizako, Koji Uchida, Shinji Hara, Yasushi Kaji, Masahiro Sumura, Mikio Igawa, Hajime Kitagaki, Mitsuhiro Uike, Tsuyoshi Matsuda

    JAPANESE JOURNAL OF RADIOLOGY   31 ( 3 )   220 - 225   2013.3

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:SPRINGER  

    The aim of this study was to determine to what extent we could identify the metabolism product peak using 3-T proton magnetic resonance spectroscopic imaging (MRSI) of the prostate gland in healthy volunteers by combining an external array coil with Malcolm Levitt composite-pulse decoupling sequence (MLEV)-point-resolved spatially localized spectroscopy (PRESS).
    MRSI data were obtained from the entire prostate gland in six healthy volunteers. The heights of the choline, citrate peaks and the standard deviation (SD) of the noise in each voxel were calculated. When the choline and/or citrate peak in a voxel exceeded 3 SD, the peak was clearly identified.
    The clear citrate peak rate in the peripheral zone (PZ) and the central gland (CG) were 78.8 and 70.3 %, respectively. The clear choline peak rate in the PZ and the CG were 55.4 and 44.9 %, respectively. In addition, the clear peak rates for both citrate and choline in the PZ and the CG were 51.8 and 38.6 %. Therefore, in the entire prostate gland, 75.2 % had a clear citrate peak, 51.1 % had a clear choline peak, and 46.3 % had both citrate and choline peaks.
    The citrate peak was clearly detected in 75.2 % of the voxels by this technique.

    DOI: 10.1007/s11604-012-0165-5

    Web of Science

    PubMed

    researchmap

  • [Analysis of accidents for magnetically induced displacement of the large ferromagnetic material in magnetic resonance systems]. Reviewed

    Yamatani Y, Doi T, Ueyama T, Nishiki S, Ogura A, Kawamitsu H, Tsuchihashi T, Okuaki T, Matsuda T

    Nihon Hoshasen Gijutsu Gakkai zasshi   69 ( 1 )   99 - 108   2013.1

     More details

  • Quantitative analysis of hepatic fat fraction by single-breath-holding MR spectroscopy with T 2 correction: Phantom and clinical study with histologic assessment Reviewed

    Norio Hayashi, Tosiaki Miyati, Takashi Minami, Yumie Takeshita, Yasuji Ryu, Tsuyoshi Matsuda, Naoki Ohno, Takashi Hamaguchi, Kenichiro Kato, Toshinari Takamura, Osamu Matsui

    Radiological Physics and Technology   6 ( 1 )   219 - 225   2013.1

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    The focus of this study was on the investigation of the accuracy of the fat fraction of the liver by use of single-breath-holding magnetic resonance spectroscopy (MRS) with T 2 correction. Single-voxel proton MRS was performed with several TE values, and the fat fraction was determined with and without T 2 correction. MRS was also performed with use of the point-resolved spectroscopy sequence in single breath holding. The T 2 values of both water and fat were determined separately at the same time, and the effect of T 2 on the fat fraction was corrected. In addition, MRS-based fat fractions were compared with the degree of hepatic steatosis (HS) by liver biopsy in human subjects. With T 2 correction, the MRI-derived fat fractions were in good agreement with the fat fractions in all phantoms, but the fat fractions were overestimated without T 2 correction. R 2 values were in good agreement with the preset iron concentrations in the phantoms. The MRI-derived fat fraction was well correlated with the degree of HS. Iron deposited in the liver affects the signal strength when proton MRS is used for detection of the fat signal in the liver. However, the fat signal can be evaluated more accurately when the T 2 correction is applied. Breath-holding MRS minimizes the respiratory motion, and it can be more accurate in the quantification of the hepatic fat fraction. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics.

    DOI: 10.1007/s12194-012-0191-0

    Scopus

    PubMed

    researchmap

  • Preliminary Observation of Dynamic Changes in Alcohol Concentration in the Human Brain with Proton Magnetic Resonance Spectroscopy on a 3T MR Instrument Reviewed

    Hitoshi Kubo, Masafumi Harada, Minoru Sakama, Tsuyoshi Matsuda, Hideki Otsuka

    MAGNETIC RESONANCE IN MEDICAL SCIENCES   12 ( 3 )   235 - 240   2013

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JPN SOC MAGNETIC RESONANCE IN MEDICINE  

    Purpose: Our purposes were to establish suitable conditions for proton magnetic resonance spectroscopy (MRS) to measure dynamic changes in alcohol concentration in the human brain, to evaluate these changes, and to compare the findings with data from analysis of breath vapor and blood samples.
    Materials and Methods: We evaluated 4 healthy volunteers (mean age 26.5 years; 3 males, one female) with no neurological findings. All studies were performed with 3-tesla clinical equipment using an 8-channel head coil. We applied our modified single-voxel point-resolved spectroscopy (PRESS) sequence. Continuous measurements of MRS, breath vapor, and blood samples were conducted before and after the subjects drank alcohol with a light meal. The obtained spectra were quantified by LCModel Ver. 6.1, and the accuracy of the MRS measurements was estimated using the estimated standard deviation expressed in percentage (%SD) as a criterion.
    Results: Alcohol peaks after drinking were clearly detected at 1.2 ppm for all durations of measurement. Good correlations between breath vapor or blood sample and MRS were found by sub-minute MRS measurement. The continuous measurement showed time-dependent changes in alcohol in the brain and various patterns that differed among subjects.
    Conclusions: The clinical 3T equipment enables direct evaluation of sub-minute changes in alcohol metabolism in the human brain.

    DOI: 10.2463/mrms.2012-0056

    Web of Science

    PubMed

    researchmap

  • [Neuroimaging using ultrahigh-field magnetic resonance imaging at 7 tesla: current concepts]. Reviewed

    Makoto Sasaki, Kohsuke Kudo, Ikuko Uwano, Hiroyuki Kabasawa, Tsuyoshi Matsuda

    Brain and nerve = Shinkei kenkyu no shinpo   64 ( 9 )   1057 - 62   2012.9

     More details

    Language:Japanese  

    The introduction of ultrahigh-field MRI at 7 tesla (7T) has increased the interest in the use of neuroimaging techniques in clinical research. The high signal-to-noise ratio and profound susceptibility effect at 7T can remarkably improve the spatial resolution and image contrast of structural imaging, susceptibility imaging, and functional imaging techniques, whereas the heating effects of the radio frequency and the inhomogeneities of the local magnetic field can have substantial negative effects on parameter setting, acquisition time, and image quality. T1 prolongation at 7T can improve the enhancement effects of gadolinium agents and the inflow effects on MR angiography and arterial spin labeling. Ultrahigh-field MRI is expected to have a high clinical impact in the near future; however, further technological advances tailored to ultrahigh-field systems as well as the accumulation of scientific evidence will be needed to establish its clinical significance.

    PubMed

    researchmap

  • MR perfusion imaging by alternate slab width inversion recovery arterial spin labeling (AIRASL): a technique with higher signal-to-noise ratio at 3.0 T Reviewed

    Yasuhiro Fujiwara, Hirohiko Kimura, Tosiaki Miyati, Hiroyuki Kabasawa, Tsuyoshi Matsuda, Yoshiyuki Ishimori, Isao Yamaguchi, Toshiki Adachi

    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE   25 ( 2 )   103 - 111   2012.4

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:SPRINGER  

    To propose a new arterial spin labeling (ASL) perfusion-imaging method (alternate slab width inversion recovery ASL: AIRASL) that takes advantage of the qualities of 3.0 T.
    AIRASL utilizes alternate slab width IR pulses for labeling blood to obtain a higher signal-to-noise ratio (SNR). Numerical simulations were used to evaluate perfusion signals. In vivo studies were performed to show the feasibility of AIRASL on five healthy subjects. We performed a statistical analysis of the differences in perfusion SNR measurements between flow-sensitive alternating inversion recovery (FAIR) and AIRASL.
    In signal simulation, the signal obtained by AIRASL at 3.0 and 1.5 T was 1.14 and 0.85%, respectively, whereas the signal obtained by FAIR at 3.0 and 1.5 T was 0.57 and 0.47%, respectively. In an in vivo study, the SNR of FAIR (3.0 T) and FAIR (1.5 T) were 1.73 +/- A 0.49 and 1.02 +/- A 0.20, respectively, whereas the SNRs of AIRASL (3.0 T) and AIRASL (1.5 T) were 3.93 +/- A 1.65 and 1.34 +/- A 0.31, respectively. SNR in AIRASL at 3.0 T was significantly greater than that in FAIR at 3.0 T.
    The most significant potential advantage of AIRASL is its high SNR, which takes advantage of the qualities of 3.0 T. This sequence can be easily applied in the clinical setting and will enable ASL to become more relevant for clinical application.

    DOI: 10.1007/s10334-011-0301-8

    Web of Science

    PubMed

    researchmap

  • Combination of two fat saturation pulses improves detectability of glucose signals in carbon-13 MR spectroscopy Reviewed

    Moyoko Tomiyasu, Tsuyoshi Matsuda, James Tropp, Toshiro Inubushi, Toshiharu Nakai

    PROCEEDINGS OF THE JAPAN ACADEMY SERIES B-PHYSICAL AND BIOLOGICAL SCIENCES   87 ( 7 )   425 - 430   2011.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JAPAN ACAD  

    In order to improve the fat suppression performance of in vivo C-13-MRS operating at 3.0 Tesla, a phantom model study was conducted using a combination of two fat suppression techniques; a. set of pulses for frequency (chemical shift) selective suppression (CHESS), and spatial saturation (SAT). By optimizing the slab thickness for SAT and the irradiation bandwidth for CHESS, the signals of the CH: peak at 49 ppm and the -(CH2)-C-13- peak at 26 ppm simulating fat components were suppressed to 5% and 19%, respectively. Combination of these two fat suppression pulses achieved a 53% increase of the height ratio of the glucose C1 beta peak compared with the sum of all other peaks, indicating better sensitivity for glucose signal detection. This method will be applicable for in vivo C-13-MRS by additional adjustment with the in vivo relaxation times of the metabolites.

    DOI: 10.2183/pjab.87.425

    Web of Science

    PubMed

    researchmap

  • Measurement of Variation in the Human Cerebral GABA Level by In Vivo MEGA-Editing Proton MR Spectroscopy using a Clinical 3 T Instrument and its Dependence on Brain Region and the Female Menstrual Cycle Reviewed

    Masafumi Harada, Hitoshi Kubo, Ayumi Nose, Hiromu Nishitani, Tsuyoshi Matsuda

    HUMAN BRAIN MAPPING   32 ( 5 )   828 - 833   2011.5

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:WILEY-BLACKWELL  

    The objectives of this study were to examine the reproducibility of the MEGA-editing J-difference technique and to determine the normal variation in the gamma-aminobutyric acid (GABA) level depending on the cerebral region and its fluctuation according to the menstrual cycle as baseline data for clinical application. The participants consisted of 15 normal adult volunteers (eight men and seven women), and all measurements were repeated twice in all participants. The MEGA-editing pulses were incorporated into point-resolved spectroscopy on a 3 T instrument to obtain the J-difference editing spectra from a voxel located in the lentiform nuclei (LN), left frontal lobe (FL), and anterior cingulate cortex (AC). The GABA levels in the gray matter (GM) were compensated by the fraction ratios of the gray and white matters and cerebrospinal fluid in the measurement volume. The extent of the variation in GABA was almost the same as that observed in the major metabolites, and its reproducibility was also maintained (intraclass correlation coefficient &gt; 0.7). GABA level was highest in LN and lowest in AC. A difference in the GABA level between the follicular and luteal phases of the menstrual cycle was found in both LN and FL, but not in AC. This technique showed the differences in the GABA levels in the GM and the region-specific decrease in the GABA levels during the women&apos;s luteal phase. Hum Brain Mapp 32: 828-833, 2011. (C) 2010 Wiley-Liss, Inc.

    DOI: 10.1002/hbm.21086

    Web of Science

    PubMed

    researchmap

  • Influence of work shift on glutamic acid and gamma-aminobutyric acid (GABA): Evaluation with proton magnetic resonance spectroscopy at 3T Reviewed

    Shingo Kakeda, Yukunori Korogi, Junji Moriya, Norihiro Ohnari, Toru Sato, Susumu Ueno, Nobuyuki Yanagihara, Masafumi Harada, Tsuyoshi Matsuda

    Psychiatry Research - Neuroimaging   192 ( 1 )   55 - 59   2011.4

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Working conditions such as shift work constitute a well-known risk factor for insomnia and excessive daytime sleepiness complaints. We compared brain gamma-aminobutyric acid (GABA), glutamic acid (Glu), glutamine (Gln), and Glx (Glu+Gln) levels in day-shift versus alternate-shift workers with proton magnetic resonance spectroscopy (1H-MRS) at 3T. The study population consisted of 32 healthy adult volunteers (16day-shift and 16 alternate-shift workers). Each subject underwent MRS conducted using a MEGA-PRESS sequence in the early morning and early evening on the same day. Spectroscopy voxels (3.0cm×3.0cm×3.0cm) were placed in the frontal lobe and parieto-occipital lobe. The GABA/Cr ratio in the frontal lobe was significantly lower for the alternate-shift group than for the day-shift group in the early evening (1.885 vs. 0.875). For the other metabolite ratios (Gln/Cr and Glx/Cr), there were no significant differences between the two groups regardless of morning or evening schedule. Our preliminary finding represents a possible alteration of GABA content in the brain related to an irregular work schedule. © 2010 Elsevier Ireland Ltd.

    DOI: 10.1016/j.pscychresns.2010.10.011

    Scopus

    PubMed

    researchmap

  • Non-Invasive Evaluation of the GABAergic/Glutamatergic System in Autistic Patients Observed by MEGA-Editing Proton MR Spectroscopy Using a Clinical 3 Tesla Instrument Reviewed

    Masafumi Harada, Masako M. Taki, Ayumi Nose, Hitoshi Kubo, Kenji Mori, Hiromu Nishitani, Tsuyoshi Matsuda

    JOURNAL OF AUTISM AND DEVELOPMENTAL DISORDERS   41 ( 4 )   447 - 454   2011.4

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:SPRINGER/PLENUM PUBLISHERS  

    Amino acids related to neurotransmitters and the GABAergic/glutamatergic system were measured using a 3 T-MRI instrument in 12 patients with autism and 10 normal controls. All measurements were performed in the frontal lobe (FL) and lenticular nuclei (LN) using a conventional sequence for n-acetyl aspartate (NAA) and glutamate (Glu), and the MEGA-editing method for GABA. The GABA level and [GABA]/[NAA] ratio were significantly lower (p &lt; 0.01) in the FL, but not the LN, in patients with autism compared to normal controls. The [GABA]/[Glu] ratio in the FL was also significantly lower (p &lt; 0.05) in the patients than in the normal controls, thus suggesting a possible abnormality in the regulation between GABA and Glu.

    DOI: 10.1007/s10803-010-1065-0

    Web of Science

    PubMed

    researchmap

  • [An investigative report concerning safety and management in the magnetic resonance environment: there are more accidents than expected]. Reviewed

    Doi T, Yamatani Y, Ueyama T, Nishiki S, Ogura A, Kawamitsu H, Tsuchihashi T, Okuaki T, Matsuda T, Kumashiro M

    Nihon Hoshasen Gijutsu Gakkai zasshi   67 ( 8 )   895 - 904   2011

     More details

  • High gamma-aminobutyric acid level in cortical tubers in epileptic infants with tuberous sclerosis complex measured with the MEGA-editing J-difference method and a three-Tesla clinical MRI Instrument Reviewed

    Masako Minato Taki, Masafumi Harada, Kenji Mori, Hitoshi Kubo, Ayumi Nose, Tsuyoshi Matsuda, Hiromu Nishitani

    NEUROIMAGE   47 ( 4 )   1207 - 1214   2009.10

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:ACADEMIC PRESS INC ELSEVIER SCIENCE  

    The purpose of this Study was to estimate the gamma-aminobutyric acid (GABA) and glutamate plus glutamine (Glx) concentrations in the cortical tubers of patients with tuberous sclerosis complex (TSC) using the MEGA-editing J-difference method and a stimulated echo-acquisition mode with a short echo time, and to determine which abnormality Was more dominant between GABA and Glx in patients with TSC with epilepsy. This study included six patients with TSC (mean age, 4.3 years) and seven control subjects (mean age, 4.8 years). Measurements were obtained with a three-Tesla apparatus and postprocessing was conducted with an LCModel. The GABA level in the cortical gray matter (cgGABA) was calculated as a result of segmentation in voxels and from the literature values for gray and white matter ratios for GABA. Increased GABA and myo-inositol (ml) concentrations and a decreased N-acetyl aspartate (NAA) concentration were observed in the cortical tubers. The cgGABA level,and cgGABA/NAA and cgGABA/GlX ratios were also higher inpatients with TSC than in Control subjects. No significant difference was found in Glx concentration between patients with TSC and control subjects. Although the number of patients with TSC in this study was small, the increase in GABA and no significant change in Glx were consistent with previous neurochemical studies and support the hypothesis that brain GABA plays a key role in the pathophysiology of epilepsy during the process of neuronal development. (C) 2009 Elsevier Inc. All rights reserved.

    DOI: 10.1016/j.neuroimage.2009.05.060

    Web of Science

    PubMed

    researchmap

  • [Suppression of CSF artifact in fast FLAIR sequence at 3.0 Tesla]. Reviewed

    Fujiwara Y, Ishimori Y, Yamaguchi I, Matsuda T, Miyati T, Kimura H

    Nihon Hoshasen Gijutsu Gakkai zasshi   64 ( 12 )   1513 - 1521   2008.12

     More details

  • Negative Correlation between Brain Glutathione Level and Negative Symptoms in Schizophrenia: A 3T H-1-MRS Study Reviewed

    Daisuke Matsuzawa, Takayuki Obata, Yukihiko Shirayama, Hiroi Nonaka, Yoko Kanazawa, Eiji Yoshitome, Junichi Takanashi, Tsuyoshi Matsuda, Eiji Shimizu, Hiroo Ikehira, Masaomi Iyo, Kenji Hashimoto

    PLOS ONE   3 ( 4 )   e1944   2008.4

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:PUBLIC LIBRARY SCIENCE  

    Background: Glutathione (GSH), a major intracellular antioxidant, plays a role in NMDA receptor-mediated neurotransmission, which is involved in the pathophysiology of schizophrenia. In the present study, we aimed to investigate whether GSH levels are altered in the posterior medial frontal cortex of schizophrenic patients. Furthermore, we examined correlations between GSH levels and clinical variables in patients.
    Methods and Findings: Twenty schizophrenia patients and 16 age-and gender-matched normal controls were enrolled to examine the levels of GSH in the posterior medial frontal cortex by using 3T SIGNA EXCITE H-1-MRS with the spectral editing technique, MEGA-PRESS. Clinical variables of patients were assessed by the Global Assessment of Functioning (GAF), Scale for the Assessment of Negative Symptoms (SANS), Brief Psychiatric Rating Scale (BPRS), Drug-Induced Extra-Pyramidal Symptoms Scale (DIEPSS), and five cognitive performance tests (Word Fluency Test, Stroop Test, Trail Making Test, Wisconsin Card Sorting Test and Digit Span Distractibility Test). Levels of GSH in the posterior medial frontal cortex of schizophrenic patients were not different from those of normal controls. However, we found a significant negative correlation between GSH levels and the severity of negative symptoms (SANS total score and negative symptom subscore on BPRS) in patients. There were no correlations between brain GSH levels and scores on any cognitive performance test except Trail Making Test part A.
    Conclusion: These results suggest that GSH levels in the posterior medial frontal cortex may be related to negative symptoms in schizophrenic patients. Therefore, agents that increase GSH levels in the brain could be potential therapeutic drugs for negative symptoms in schizophrenia.

    DOI: 10.1371/journal.pone.0001944

    Web of Science

    PubMed

    researchmap

  • Ischemic findings of T-2*-weighted 3-tesla MRI in acute stroke patients Reviewed

    Naomi Morita, Masafumi Harada, Masaaki Uno, Shunji Matsubara, Tsuyoshi Matsuda, Shinji Nagahiro, Hiromu Nishitani

    CEREBROVASCULAR DISEASES   26 ( 4 )   367 - 375   2008

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:KARGER  

    Background: We compared ischemic findings on gradient echo-type T-2*-weighted images at 3-tesla MRI (T-2* WI) in patients with acute ischemia and major vessel occlusion, and stroke patients with lacunar infarction or branch atheromatous disease. Methods: Our study population consisted of 45 patients with acute stroke. They underwent 3-tesla MRI within 12 h of stroke onset. Included were 24 patients (13 men and 11 women, mean age 68 years) with major vessel occlusion and 21 patients (11 men and 10 women, mean age 69 years) with minor infarction such as lacunar infarcts or branch atheromatous disease. We classified vascular ischemic findings of T-2* WI into 3 sign categories, i.e. artery susceptibility sign, cortical vessel sign (hypointensity and enlargement of the cortical vessels) and brush sign (hypointensity of vessels in the deep white matter). Decreased intensity in the ischemic parenchyma was designated ischemic tissue sign. We compared regions of interest in the hypoperfused area on flow-sensitive alternating inversion recovery (FAIR) images with our vascular ischemic findings. Results: None of the vascular ischemic signs nor the ischemic tissue sign were found in patients with minor vessel disease. All 24 patients with major vessel occlusion manifested the cortical vessel sign, 23 the brush sign. The area with ischemic vessel signs on T-2* WI was almost as large or somewhat smaller than the hypoperfused area on FAIR images. Compared to the contralateral side, 14 of 24 patients (58.3%) with major vessel occlusion showed decreased intensity in the ischemic parenchyma (ischemic tissue sign). Region of interest measurements on FAIR images demonstrated greater hypoperfusion in the area classified as ischemic tissue sign on T-2* WI. Conclusions: Ischemic vessel signs and the ischemic tissue sign on T-2* WI at 3 T would be useful to evaluate the extensive ischemia due to major vessel occlusion and may be correlated with the blood-oxygen-level-dependent effect due to increased deoxyhemoglobin. The ischemic tissue sign may be reflective of severe ischemia. Copyright (C) 2008 S. Karger AG, Basel.

    DOI: 10.1159/000151640

    Web of Science

    PubMed

    researchmap

  • [Reduction of vascular artifact on T1-weighted images of the brain by using three-dimensional double IR fast spoiled gradient echo recalled acquisition in the steady state (FSPGR) at 3.0 Tesla]. Reviewed

    Fujiwara Y, Matsuda T, Ishimori Y, Yamaguchi I, Hayashi H, Ookoshi Y, Ootani Y, Miyati T, Kimura H

    Nihon Hoshasen Gijutsu Gakkai zasshi   63 ( 11 )   1239 - 1245   2007.11

     More details

  • Assessment of the vascularity of uterine leiomyomas using double-echo dynamic perfusion-weighted MRI with the first-pass pharmacokinetic model - Correlation with histopathology Reviewed

    Nobuyuki Kosaka, Hidemasa Uematsu, Hirohiko Kimura, Yoshiyuki Ishimori, Tetsuji Kurokawa, Tsuyoshi Matsuda, Harumi Itoh

    INVESTIGATIVE RADIOLOGY   42 ( 9 )   629 - 635   2007.9

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:LIPPINCOTT WILLIAMS & WILKINS  

    Objectives: To retrospectively evaluate the feasibility of perfusion-weighted MRI (PWI) in uterine leiomyomas.
    Materials and Methods: Eighteen uterine leiomyomas in 15 patients were evaluated. PWI was performed using a double-echo T2*-weighted spoiled gradient-recalled acquisition sequence, and the first-pass pharmacokinetic model was applied to calculate relative blood volume (rBV). Histopathologic analysis was performed to measure vascular area (VA).
    Results: PWI was successful in 13 of 15 patients. On quantitative analysis, mean (+/- SD) rBV calculated from PWI was 0.17 +/- 0.13 (range, 0.06-0.55), whereas mean VA was 3.3% +/- 1.6% (range, 1.7-8.5%). A significant correlation was identified between rBV and VA (r = 0.87, P &lt; 0.001).
    Conclusions: The rBV determined at PWI correlates with histologic vascular area in uterine leiomyomas.

    DOI: 10.1097/RLI.0b013e318059ae69

    Web of Science

    PubMed

    researchmap

  • [New method of determining regional fat fraction with modulus and real multiple gradient-echo (MRM-GRE)]. Reviewed

    Nobuyuki Arai, Tosiaki Miyati, Sayoko Matsunaga, Yuko Motono, Yuu Ueda, Harumasa Kasai, Yuriko Suzuki, Tsuyoshi Matsuda

    Nihon Hoshasen Gijutsu Gakkai zasshi   63 ( 3 )   312 - 8   2007.3

     More details

    Language:Japanese  

    We devised a method of analyzing a regional fat fraction using a modulus and real multiple gradient-echo (MRM-GRE) 4-7 echo Dixon sequence. The regional fat fraction was calculated with a theoretically fitted signal-intensity curve for multiple GRE images at each echo time (i.e., 4-7 echoes.) on a 1.5 Tesla MRI to correct T2* decay and phase cycling. Then the real image of the first echo was used to differentiate between the areas above and below the 50 percent fat fraction. To eliminate the T1-effect, the flip angle was set at 12 degrees. Fat fractions of the phantom with MRM-GRE were compared with those using conventional double-GRE and other MRI techniques. Fat fractions of liver and spinal bone marrow in healthy volunteers were determined during a breath-hold. The fat fraction of the phantom obtained by the MRM-GRE method tended to agree with the actual fat fraction. On the other hand, in both the phantom and in healthy volunteers, the double-GRE was underestimated owing to T2* decay. The MRM-GRE method enables simple, accurate analysis of the regional fat fraction.

    PubMed

    researchmap

  • Anatomical and metabolic assessment of prostate using a 3-Tesla MR scanner with a custom-made external transceive coil: Healthy volunteer study Reviewed

    Yasushi Kaji, Kagayaki Kuroda, Takaki Maeda, Yuri Kitamura, Toshitaka Fujiwara, Yuichiro Matsuoka, Mitsuru Tamura, Naoyuki Takei, Tsuyoshi Matsuda, Kazuro Sugimura

    JOURNAL OF MAGNETIC RESONANCE IMAGING   25 ( 3 )   517 - 526   2007.3

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JOHN WILEY & SONS INC  

    DOI: 10.1002/jmri.20829

    Web of Science

    PubMed

    researchmap

  • [Optimization of three-dimensional triple IR fast spoiled gradient recalled acquisition in the steady state (FSPGR) to decrease vascular artifact at 3.0 Tesla]. Reviewed

    Fujiwara Y, Matsuda T, Ishimori Y, Yamada K, Fukuya Y, Yamaguchi I, Kimura H, Miyati T

    Nihon Hoshasen Gijutsu Gakkai zasshi   62 ( 11 )   1560 - 1565   2006.11

     More details

  • Cerebral hyperperfusion in a patient with eclampsia with perfusion-weighted magnetic resonance imaging Reviewed

    Mayumi Takeuchi, Kenji Matsuzaki, Masafumi Harada, Hiromu Nishitani, Tsuyoshi Matsuda

    Radiation Medicine - Medical Imaging and Radiation Oncology   23 ( 5 )   376 - 379   2005.8

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    The patient was a 25-year-old Japanese woman with postpartum eclampsia, in whom magnetic resonance imaging (MRI) was performed ten hours after convulsion. The patient improved within three days. Diffusion-weighted images showed a high apparent diffusion coefficient (ADC), and perfusion-weighted images obtained by the multi-slice flow-sensitive alternating inversion recovery (FAIR) method showed hyperperfusion, which was suggestive of vasogenic edema, on the parietal and occipital subcortical white matter, corresponding with transient hyperintensities on T2-weighted images. MR angiography (MRA) revealed no signs of vasospasm. These findings suggested hyperperfusion-induced vasogenic edema without cerebrovascular spastic change in the early stage of eclampsia. The FAIR method is considered a useful technique for perfusion-weighted MRI, especially useful to evaluate the cerebral perfusion of emergency patients such as those with eclampsia.

    Scopus

    PubMed

    researchmap

  • Assessment of the specific absorption rate and calibration of decoupling parameters for proton decoupled carbon-13 MR spectroscopy at 3.0 T Reviewed

    M Saito, T Matsuda, J Tropp, T Inubushi, T Nakai

    EUROPEAN JOURNAL OF RADIOLOGY   55 ( 2 )   289 - 293   2005.8

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:ELSEVIER IRELAND LTD  

    A strategy for proton decoupled carbon-13 MR spectroscopy ({H-1}-C-13 MRS) with a strong static magnetic field (3.0T) in vivo was investigated. The proton decoupling improves the signal-to-noise ratio, however, the effect of the decoupling power on the human body, especially in strong magnetic fields, should be considered. In order to establish a technique for monitoring the metabolism of glucose in the liver using {H-1}-C-13 MRS at 3.0T, two phantom experiments were performed. To assess whether the decoupling energy conformed to SAR limits defined by the IEC, temperature rises inside an agar gel phantom were monitored during a {H-1}-C-13 MRS experiment. Then, the decoupling conditions of a glucose solution phantom were systematically optimized with combinations of decoupling bandwidth and power. The reliability of this procedure was discussed in conjunction with IEC guidelines. (C) 2004 Elsevier Ireland Ltd. All rights reserved.

    DOI: 10.1016/j.ejrad.2004.11.011

    Web of Science

    PubMed

    researchmap

  • [Fundamental study of magnetization transfer contrast (MTC) effect: optimization of MT pulse condition using experimental phantom]. Reviewed

    Kawata H, Nishimura H, Nagata S, Matsuda T, Takada K, Hayabuchi N

    Nihon Hoshasen Gijutsu Gakkai zasshi   60 ( 10 )   1437 - 1443   2004.10

     More details

  • Correlation between flow-sensitive alternating inversion recovery perfusion imaging with different inversion times and cerebral flow reserve evaluated by single-photon-emission computed tomography Reviewed

    M Harada, M Uno, K Yoneda, A Hori, H Nishitani, T Matsuda

    NEURORADIOLOGY   46 ( 8 )   649 - 654   2004.8

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:SPRINGER  

    The purpose of this study was to evaluate the effect of different inversion times (TIs) on flow-sensitive alternating inversion recovery (FAIR) perfusion imaging and compare them with the cerebral blood flow reserve evaluated by acetazolamide challenge using single-photon-emission computed tomography (SPECT). The subjects were nine patients with unilateral obstruction of the internal carotid artery. The signal ratio (SR16/8) of two images with different TIs (1,600 ms and 800 ms) was calculated, and the cerebral blood flow reserve (CFR) was evaluated by the increase in the ratio of cerebral perfusion after administration of acetazolamide in the SPECT study. A reversed linear correlation ( r =0.75) was found between SR and CFR, indicating that differences of FAIR images with changes of TI will be affected by cerebral flow reserve.

    DOI: 10.1007/s00234-004-1228-9

    Web of Science

    PubMed

    researchmap

  • Centrally fat-saturated three-dimensional magnetic resonance angiography of the abdomen using selective central fat-saturation of K-space Reviewed

    Y Amano, K Takahama, T Matsuda, M Amano, T Kumazaki

    JOURNAL OF MAGNETIC RESONANCE IMAGING   18 ( 5 )   567 - 574   2003.11

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JOHN WILEY & SONS INC  

    Purpose: To assess the usefulness of centrally fat-saturated three-dimensional magnetic resonance (MR) angiography of the abdomen using an elliptical centric view order and selective placement of fat-saturation pulses in the central 30% portion of the k-space in terms of fat signal reduction, image contrast of post-contrast images, and breath-holding time.
    Methods: Fat signal in abdomen and breath-holding time were compared between centrally fat-saturated three-dimensional sequence and partially fat-saturated three-dimensional sequence or conventional fat-saturated three-dimensional sequence. Abdominal contrast-enhanced centrally fat-saturated three-dimensional MR angiography was obtained at arterial and equilibrium phases, and image quality was quantitatively and visually evaluated.
    Results: Centrally fat-saturated three-dimensional sequence suppressed fat signal, as did the conventional fat-saturated three-dimensional sequence, and the breath-hold was prolonged only by 1.5 seconds compared to the partially fat-saturated three-dimensional sequence. Contrast-enhanced centrally fat-saturated three-dimensional MR angiography provided abdominal MR arteriography with large signal difference between vessels and fat, while venous signal was insufficient at equilibrium phase.
    Conclusion: : Abdominal contrast-enhanced centrally fat-saturated three-dimensional MR angiography using an elliptical centric view order and selective central fat-saturation of k-space reduced fat signal comparable to conventional fat-saturated three-dimensional sequence, and provided contrast-enhanced MR arteriography with high vascular contrast and minimum prolongation of breath-hold.

    DOI: 10.1002/jmri.10385

    Web of Science

    PubMed

    researchmap

  • [Description of the fast scan method in MRI]. Reviewed

    Matsuda T

    Nihon Hoshasen Gijutsu Gakkai zasshi   59 ( 10 )   1209 - 1217   2003.10

     More details

  • Comparison of FAIR technique with different inversion times and post contrast dynamic perfusion MRI in chronic occlusive cerebrovascular disease Reviewed

    K Yoneda, M Harada, N Morita, H Nishitani, M Uno, T Matsuda

    MAGNETIC RESONANCE IMAGING   21 ( 7 )   701 - 705   2003.9

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:ELSEVIER SCIENCE INC  

    The purpose of this study was to examine the signal change occurring with different inversion times (TIs) of the flow-sensitive alternating inversion recovery (FAIR) technique and to compare with the perfusion image obtained with Gd-DTPA injection. The subjects were 11 patients with unilateral occlusive cerebrovascular disease. Two FAIR images with different TIs (800 ms and 1600 ms) were measured for each patient and dynamic perfusion MRI was performed to produce four kinds of parameter maps: mean transit time (MTT), time to peak (TTP), relative cerebral blood flow (rCBF) and relative cerebral blood volume (rCBV) maps. Asymmetry ratios (ARs) between the affected and contra-lateral vascular sides were measured in both FAIR images and the four dynamic parameter maps. The AR of the MTT map of the four parameters showed the highest correlation with that of the FAIR images, especially with that of TI = 1600 ms (r = 0.829), and the AR of the rCBV map revealed the worst correlation with the FAIR images. The AR of the FAIR image with TI = 800 ms was less correlated with that of MTT than that with TI = 1600 ms. These results suggested that the signal intensity of the FAIR image was influenced by flow transition time and the change in TI could be used to select the flow with a different transition time. Our study suggested that a longer TI in the FAIR technique might be more useful than a shorter TI for evaluating chronic occlusive cerebrovascular disease in the clinical setting. (C) 2003 Elsevier Inc. All rights reserved.

    DOI: 10.1016/S0730-725X(03)00104-8

    Web of Science

    PubMed

    researchmap

  • Dynamic T1 estimation of brain tumors using double-echo dynamic MR imaging Reviewed

    Y Ishimori, H Kimura, H Uematsu, T Matsuda, H Itoh

    JOURNAL OF MAGNETIC RESONANCE IMAGING   18 ( 1 )   113 - 120   2003.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JOHN WILEY & SONS INC  

    Purpose: To assess the clinical utility of a new method for real-time estimation of T1 during the first pass of contrast agent by using this method to examine brain tumors.
    Materials and Methods: The multi-phase spoiled gradient-echo pulse sequence using the double-echo magnetic resonance (MR) technique was modified. In the first half of the pulse sequence, the flip angle was varied systematically. Then, static T1 values were calculated using differences in MR signal intensities between different flip angles. In the latter half of this sequence, changes in absolute T1 were calculated using differences in signal intensities before and after injection of contrast agent. The double-echo MR data were used to minimize the T2* effect. Five cases of neurinoma and seven cases of meningioma were examined. Changes in T1 during the first pass of contrast agent were compared between neurinoma and meningioma.
    Results: Changes in absolute T1 were clearly demonstrated on the parametric map. Although the changes in absolute T1 during the first pass of contrast agent did not allow differentiation between the two types of tumors, the mean gradient after the first pass was statistically higher for neurinoma than for meningioma (P &lt; 0.05; meningioma, 0.011 +/- 0.012 second(-1)/second; neurinoma, 0.034 +/- 0.020 second(-1)/second).
    Conclusion: The present method appears to be useful for estimation of dynamic T1 changes in brain tumors in clinical settings.

    DOI: 10.1002/jmri.10331

    Web of Science

    PubMed

    researchmap

  • [Study of elliptical centric view ordering technique with spectrally selected inversion recovery pulse (spec-IR pulse)]. Reviewed

    Okuaki T, Yamashita M, Wakamatsu O, Shirouzu I, Machida T, Matsuda T

    Nihon Hoshasen Gijutsu Gakkai zasshi   59 ( 3 )   401 - 409   2003.3

     More details

  • Fat-suppressed three-dimensional MR angiography technique with elliptical centric view order and no prolonged breath-holding time Reviewed

    Y Amano, M Amano, T Matsuda, T Tsuchihashi, K Takahama, T Kumazaki

    JOURNAL OF MAGNETIC RESONANCE IMAGING   16 ( 6 )   707 - 715   2002.12

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JOHN WILEY & SONS INC  

    Purpose: To determine the appropriate rate of fat suppression pulses (using spec IR-spectral selective inversion recovery) for fat-suppressed 3D magnetic resonance angiography (MRA) with an elliptical centric view order.
    Materials and Methods: In abdominal 3D fast spoiled gradient echo (fast SPGR) with an elliptical centric view order the spec IR pulse rate was changed from zero to one every 15 repetitions (in nine steps) in eight volunteers. In the equilibrium phase, abdominal contrast enhanced 3D MRA was obtained by 3D fast SPGR using an elliptical centric view order without fat-suppression and with two spec IR, and by fat-suppressed 3D fast SPGR with a sequential centric view order (efgre 3D) in 18 cases. Fat and vascular signals were estimated.
    Results: Although 3D fast SPGR using in elliptical centric view order with spec IR placed every 15 TR and efgre3D effectively decreased fat signals, these sequences lengthened the breath-hold by 4-6 seconds compared with nonfat suppressed sequence. 3D fast SPGR using in elliptical centric view order and two spec IR reduced the fat signal by 30% and provided good 3D MR angiography without substantial prolongation of breath-hold.
    Conclusion: Two spec IR can be used for generation of partially fat-suppressed abdominal 3D MRA without prolongation of the breath hold when performing 3D fast SPGR using an elliptical centric view order.

    DOI: 10.1002/jmri.10200

    Web of Science

    PubMed

    researchmap

  • Measurement of the vascularity and vascular leakage of gliomas by double-echo dynamic magnetic resonance imaging - A preliminary study Reviewed

    H Uematsu, M Maeda, N Sadato, Y Ishimori, T Matsuda, Y Koshimoto, H Kimura, H Yamada, Y Kawamura, H Takeuchi, Y Yonekura, H Itoh

    INVESTIGATIVE RADIOLOGY   37 ( 10 )   571 - 576   2002.10

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:LIPPINCOTT WILLIAMS & WILKINS  

    RATIONALE AND OBJECTIVE. To evaluate the vascularity and vascular leakage of well-enhanced gliomas by double-echo dynamic magnetic resonance (MR) imaging.
    MATERIALS AND METHODS. Eight patients with glioblastoma multiforme (GBM) and two patients with juvenile pilocytic astrocytoma (JPA) were studied. Double-echo dynamic MR imaging was utilized to separate the T2* shortening effect and the T1 shortening effect. The former was represented by the vascularity index, and the latter was represented by the leakage index. These indexes were compared with histopathologic data.
    RESULTS. The mean vascularity index of the GBM was higher than that of the JPA (mean +/- SD, 3.48 +/- 1.57 [GBM] versus 0.51 +/- 0.29 [JPA]), and the mean leakage index of the JPA was higher than that of the GBM (1.35 +/- 0.87 [JPA] versus 0.27 +/- 0.15 [GBM]). Abundant vascularity was noted in the tight interstitial space in the pathologic specimen of GBM. Conversely, sparse vasculature was observed in the wide interstitial space in the pathologic specimen of JPA.
    CONCLUSION. This method may enable better characterization of grade in well-enhanced glioma by providing the information on the vascularity and leakage indexes.

    DOI: 10.1097/01.RLI.0000028483.51109.29

    Web of Science

    PubMed

    researchmap

  • Differentiation of prostate cancer from benign prostate hypertrophy using dual-echo dynamic contrast MR imaging Reviewed

    S Muramoto, H Uematsu, H Kimura, Y Ishimori, N Sadato, N Oyama, T Matsuda, Y Kawamura, Y Yonekura, K Okada, H Itoh

    EUROPEAN JOURNAL OF RADIOLOGY   44 ( 1 )   52 - 58   2002.10

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:ELSEVIER SCI IRELAND LTD  

    Objective: To investigate the usefulness of dynamic contrast magnetic resonance (MR) imaging in the differentiation of prostate cancer (PC) from benign prostate hypertrophy (BPH). Materials and methods: Eleven PC patients and 13 BPH patients were entered into the analysis. The mean gradient (MG) was calculated from the T2* term-eliminated time-signal intensity curve obtained from dynamic contrast MR data, and the MG of PC and that of BPH were compared. Results: The MG of PC was significantly higher than that of BPH. When the threshold value was set to per s for discriminating PC from BPH, the sensitivity, specificity, and accuracy were 100, 85, and 92%, respectively. Conclusions: The MG, which is derived from the T2* term-eliminated time-signal intensity curve, may be a useful index for differentiating PC from BPK (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

    Web of Science

    PubMed

    researchmap

  • H-2 (15)0 positron emission tomography validation of semiquantitative prostate blood flow determined by double-echo dynamic MRI: A preliminary study Reviewed

    S Muramoto, H Uematsu, N Sadato, T Tsuchida, T Matsuda, H Hatabu, Y Yonekura, H Itoh

    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY   26 ( 4 )   510 - 514   2002.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:LIPPINCOTT WILLIAMS & WILKINS  

    Purpose: Information regarding prostate blood flow as determined by positron emission tomography (PET) with (H2O)-O-15 may provide useful information about tumor diagnosis; however, PET requires a cyclotron for the production of an extremely short half-life (2 minutes) tracer. Therefore, the aim of this study was to propose a complementary index for blood flow as determined by MRI to validate the results and compare them with PET, especially for prostate tissue.
    Methods: Six consecutive patients with prostate disease were studied. The two semiquantitative indices for tumor blood flow were calculated from the time-concentration curve measured from double-echo MR images. The theory of nondiffusible tracers by means of indicator dilution theory was applied to MR data. The relative regional blood flow (rrBF) was calculated as the ratio of the relative regional blood volume to relative regional mean transit time. Another proposed index was the maximum height of the time-concentration curve. PET studies Were also performed. and absolute blood flow values were calculated for each subject. These indices calculated from different modalities were then compared.
    Results: A significant correlation was found between the rrBF and the absolute blood flow as determined by PET (r(2) = 0.69, p &lt; 0.005). A significant correlation was also found between the maximum height of the time-concentration curve and the absolute blood flow (r(2) = 0.85, p &lt; 0.0001).
    Conclusions: The semiquantitative tumor blood flow indices measured with MRI have a good correlation with the corresponding measurements by PET therefore, these indices may provide useful information about tumor diagnosis in clinical settings.

    DOI: 10.1097/01.RCT.0000028234.30636.26

    Web of Science

    PubMed

    researchmap

  • [Effect of relaxation time in flair magnetic resonance imaging]. Reviewed

    Matsuda T

    Nihon Hoshasen Gijutsu Gakkai zasshi   58 ( 7 )   895 - 903   2002.7

     More details

  • Diffusion-weighted in vivo localized proton MR spectroscopy of human cerebral ischemia and tumor Reviewed

    M Harada, M Uno, F Hong, S Hisaoka, H Nishitani, T Matsuda

    NMR IN BIOMEDICINE   15 ( 1 )   69 - 74   2002.2

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:JOHN WILEY & SONS LTD  

    The apparent diffusion coefficients (ADCs) of water and brain metabolites were determined by proton MR spectroscopy on a clinical MR scanner for healthy volunteers and for pathological changes in cases of acute cerebral infarction and brain tumor. The ADCs of N-acetyl aspartate (NAA) and creatines in tissue involved in acute infarction were decreased compared to normal control values, while in tumors they showed increased values. Since NAA is a neuronal marker, these findings suggest that neuronal cell viscosity changes according to the pathological status of the tissue. The lactate ADC was significantly larger than the values for other major metabolites in cases of ischemia and tumor, suggesting that lactate is present in a different compartment. These results indicate that metabolite diffusion data can be used to reveal changes in the intracellular environment depending on the pathological status. Copyright (C) 2001 John Wiley Sons, Ltd.

    DOI: 10.1002/nbm.759

    Web of Science

    PubMed

    researchmap

  • Evaluation of efficacy of an automated single-voxel proton MRS algorithm on a 3T system Reviewed

    Masaki Ohkubo, Teruo Kimura, Hitoshi Matsuzawa, Tsuyoshi Matsuda, Ingrid L. Kwee, Tsutomu Nakada

    Magnetic Resonance in Medical Sciences   1 ( 2 )   121 - 124   2002

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Purpose: To evaluate the efficacy of a fully automatic, single-voxel, proton MR spectroscopy algorithm on a 3.0T MR system. Methods: The PROBE/SVQ algorithm (GE Medical Systems) was evaluated on a General Electric (GE) Signa LX-3T system. Ten normal volunteers (female, 21.1±2.0 years old) participated in the study. Nine representative regions of interest were examined, namely, right and left frontal white matter
    right and left parietal white matter
    right and left basal ganglia
    right and left dentate nucleus
    and pons. Results: The mean coefficients of variation in all regions for the N-acetyl-aspartate to creatine ratio (NAA/Cr), choline to creatine ratio (Cho/Cr), and choline to N-acetyl-aspartate ratio (Cho/NAA) were 10.2±2.4%, 11.4±3.2% and 12.6±1.4%, respectively. Conclusion: A fully automated spectroscopic examination under clinical setting utilizing the PROBE/SVQ algorithm appears to be a reliable method, extending the window of routine clinical assessment of brain metabolism. © 2002 by Japanese Society for Magnetic Resonance in Medicine.

    DOI: 10.2463/mrms.1.121

    Scopus

    PubMed

    researchmap

  • Blood volume of gliomas determined by double-echo dynamic perfusion-weighted MR imaging: A preliminary study Reviewed

    H Uematsu, M Maeda, N Sadato, T Matsuda, Y Ishimori, Y Koshimoto, H Kimura, H Yamada, Y Kawamura, Y Yonekura, H Itoh

    AMERICAN JOURNAL OF NEURORADIOLOGY   22 ( 10 )   1915 - 1919   2001.11

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:AMER SOC NEURORADIOLOGY  

    BACKGROUND AND PURPOSE: After bolus injection, gadopentetate dimeglumine causes a T2* rate change in permeable tissue that is contaminated by the T1 shortening effect due to the leakage of contrast agent. Therefore, tumor vascularity as reported in previous single-echo perfusion-weighted MR imaging studies has been underestimated. Our aim was to quantitatively and qualitatively evaluate the degree of blood volume of glioblastoma multiformes (GBMs) underestimated by this T1 shortening effect.
    METHODS: We used double-echo dynamic MR imaging after a bolus injection of gadopentetate dimeglumine (double-echo perfusion-weighted MR imaging) to simultaneously determine tumor blood volume without (V-T1U) and with (V-T1C) T1 shortening correction. MR imaging was performed in five consecutive patients with GBMs. The ratios Of V-T1U and V-T1C were calculated and compared by means of quantitative analysis. The degree of tumor blood volume as determined by VT1U and V-T1C maps were qualitatively compared using a three-point scale.
    RESULTS: All GBMs showed contrast enhancement on postcontrast T1-weighted images. In all subjects, the values Of V-T1U were significantly lower than those Of V-T1C (mean +/- SD, 2.05 +/- 1.01 vs. 3.62 +/- 1.40, respectively [P &lt; .05]), indicating that tumor blood volume obtained by double-echo perfusion-weighted MR imaging was significantly higher than that by single-echo imaging. In the qualitative analysis, tumor blood volume on the VT1U map was less conspicuous than that on the V-T1C map.
    CONCLUSION. Careful attention should be paid to the underestimation of tumor blood volume resulting from T1 shortening effects when using single-echo perfusion-weighted MR imaging. Double-echo imaging may be more suitable for the analysis of blood volume in GBMs.

    Web of Science

    researchmap

  • Vascular permeability: Quantitative measurement with double-echo dynamic MR imaging - Theory and clinical application Reviewed

    Hidemasa Uematsu, Masayuki Maeda, Norihiro Sadato, Tsuyoshi Matsuda, Yoshiyuki Ishimori, Yoshio Koshimoto, Hiroki Yamada, Hirohiko Kimura, Yasutaka Kawamura, Tetsuya Matsuda, Nobushige Hayashi, Yoshiharu Yonekura, Yasushi Ishii

    Radiology   214 ( 3 )   912 - 917   2000

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Radiological Society of North America Inc.  

    Double-echo dynamic magnetic resonance (MR) imaging was used to evaluate both vascularity and permeability of tissues simultaneously. Vascularity was evaluated on the basis of the T2*-shortening effect due to the intravascular fraction of the contrast agent and permeability on the basis of the T1- shortening effect due to the extravascular fraction. Meningioma was characterized on the basis of higher vascularity and neurinoma on the basis of higher permeability. The proposed method enables better tissue characterization.

    DOI: 10.1148/radiology.214.3.r00mr15912

    Scopus

    PubMed

    researchmap

  • Hemodynamic and metabolic changes of acute cerebral infarction evaluated by flow-sensitive alternating IR (FAIR) image and spectroscopic imaging (CSI), and comparison with dynamic cerebral perfusion SPECT Reviewed

    M Harada, M Uno, T Okada, H Nishitani, T Matsuda

    ULTRAFAST MAGNETIC RESONANCE IMAGING IN MEDICINE   1192   271 - 274   1999

     More details

    Language:English   Publishing type:Research paper (international conference proceedings)   Publisher:ELSEVIER SCIENCE BV  

    We evaluated hemodynamic change of acute cerebral infarction using FAIR sequence and found that MRI offers almost the same information as perfusion SPECT. However semi-quantitative result showed underestimation on low perfusion by FAIR compared with SPECT.
    The metabolite change of acute cerebral infarction was estimated using CSI and the peripheral area of infarction showed lactate peak without NAA decrease, We considered that metabolic ratios as NAA/Cr and Lactate/Cr can be used as a threshold for discriminating ischemic penumbra.

    Web of Science

    researchmap

  • Quantitative measurement of vascular permeability of brain tumors by double echo dynamic MRI. Reviewed

    H Uematsu, M Maeda, N Sadato, T Matsuda, Y Ishimori, Y Koshimoto, H Yamada, H Kimura, Y Kawamura, T Matsuda, N Hayashi, Y Yonekura, Y Ishii

    ULTRAFAST MAGNETIC RESONANCE IMAGING IN MEDICINE   1192   225 - 228   1999

     More details

    Language:English   Publishing type:Research paper (international conference proceedings)   Publisher:ELSEVIER SCIENCE BV  

    The purpose of this study is to determine the tissue characterization of meningiomas and neurinomas using a "permeability index" obtained from double echo dynamic MRI. The permeability index is the index of the vascular permeability. For the present study, the permeability index was obtained by dynamic MRI using a double echo technique after a bolus injection of Gd-DTPA. Eleven patients with acoustic neurinomas and 11 patients with meningiomas were studied. Although, in some cases, the permeability index overlapped, the mean permeability index of neurinomas was much higher than that of meningiomas. The permeability index proposed here provided useful information for characterizing the tissue; this index may prove helpful in differentiating between meningiomas and neurinomas in the clinical setting.

    Web of Science

    researchmap

  • Significance of magnetic resonance image and blood manganese measurement for the assessment of brain manganese during total parenteral nutrition in rats Reviewed

    Hirotaka Chaki, Akihiko Matsuda, Kenji Yamamoto, Yukifumi Kokuba, Mikiko Kataoka, Yasuhisa Fujibayashi, Tsuyoshi Matsuda, Kazutaka Yamamoto

    Biological Trace Element Research   63 ( 1 )   37 - 50   1998

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Humana Press  

    In this study, we report on the influence of trace elements (TE) on signal intensities of nuclear magnetic resonance images (MRI), both in vivo and in vitro. Optimal parameters for the assessment of Mn concentration in the brain of rats on total parenteral nutrition were established. For the in vitro study, Mn and trace element solutions, one containing Zn, Cu, Fe, and I (TE-4) and another containing the above elements plus Mn (TE-5), were diluted with physiological saline or with rat brain homogenate and used to measure signal intensities in MRI. Concentration-dependent signal hyperintensity was observed in both cases in the Mn and the TE-5 solutions, but no effect was observed with the TE-4 solution. The signal increase was greater for brain tissue homogenates. In the in vivo study, the experimental animals were maintained under total parenteral nutrition (TPN) with a standard clinical dose of TE-5 and/or with 10-fold the clinical dose of TE-4 and TE-5 for 1 wk. Only rats that were receiving the increased TE-5 dose showed signal hyperintensity on MRI. Positive correlations were observed among the signal hyperintensity, the blood Mn concentrations, and that of the rat brain. Our results suggest that Mn in TE preparations may be the cause of signal hyperintensity on MRI in a concentration-dependent fashion, and that MRI and measurement of blood Mn may be used to estimate Mn accumulation in brain tissue.

    DOI: 10.1007/BF02785276

    Scopus

    PubMed

    researchmap

  • Evaluation of peri-infarcted hypoperfusion with T2*-weighted dynamic MRI Reviewed

    C Tsuchida, H Yamada, M Maeda, N Sadato, T Matsuda, Y Kawamura, N Hayashi, K Yamamoto, Y Yonekura, Y Ishii

    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING   7 ( 3 )   518 - 522   1997.5

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:SOC MAGNETIC RESONANCE IMAGING  

    The purpose of this study was to evaluate cerebral perfusion with T2*-weighted dynamic MRI in the area around the infarcted core, We examined seven patients with subacute cerebral infarction. After bolus injection of gadopentetate dimeglumine, a series of gradient-echo images were recorded in a selected slice, From these images, concentration-time curves were created on a region-of-interest [ROI] basis around infarction for calculating relative regional cerebral blood volume (rrCBV), Brain perfusion single photon emission computed tomography (SPECT) study also was performed with intravenous injection of I-123-labeled N-isopropyl-p-iodoamphetamine (I-123-IMP). All patients showed prolonged signal decrease in the area around the infarcted core. ROI analysis showed significantly increased rrCBV compared to the normal side (P &lt;.01, paired t test). The I-123-IMP SPECT study showed that these areas had decreased cerebral blood flow, These findings suggest compensatory vascular dilatation due to decreased perfusion pressure. T2*-weighted dynamic MRI is a useful method for detecting compensatory vasodilatation of ischemic insult in the periinfarcted area.

    Web of Science

    researchmap

  • Cortical and subcortical tubers in tuberous sclerosis and flair sequence Reviewed

    Masayuki Maeda, Armando Tartaro, Tsuyoshi Matsuda, Yasushi Ishii

    Journal of Computer Assisted Tomography   19 ( 4 )   660 - 661   1995

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.1097/00004728-199507000-00033

    Scopus

    PubMed

    researchmap

  • Metabolic alterations in the neonate and infant brain during development: Evaluation with proton MR spectroscopy Reviewed

    H. Kimura, Y. Fujii, S. Itoh, T. Matsuda, T. Iwasaki, M. Maeda, Y. Konishi, Y. Ishii

    Radiology   194 ( 2 )   483 - 489   1995

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    PURPOSE: To evaluate the usefulness of hydrogen-1 magnetic resonance (MR) spectroscopy in the evaluation of the developing brain. MATERIALS AND METHODS: Localized MR spectra were obtained with an echo time of 272 msec from the brain of 78 neonates and infants aged 1 week to 100 months. All patients were retrospectively classified into three groups on the basis of neurologic development: abnormal (group 2, n = 21), normal despite minor neurologic signs (group 1, n = 23), and normal (group 0, n = 34). RESULTS: Seventeen patients in group 2 and eight patients in group 1 revealed abnormally low N-acetylaspartate (NAA)/choline or NAA/creatine ratios compared with those obtained in group 0. MR spectroscopy was slightly more useful in the differentiation of patients in groups 2 and 1 (x2 test, P &lt
    .005) than MR imaging (P &lt
    .01). CONCLUSION: H-1 MR spectroscopy provides prognostic information about the brain in healthy and neurologically damaged infants and augments the value of MR imaging.

    Scopus

    PubMed

    researchmap

  • Cerebrospinal fluid flow void in children Reviewed

    K. Hayakawa, Y. Konishi, M. Kuriyama, K. Konishi, T. Matsuda

    Neuroradiology   35 ( 6 )   443 - 446   1993.1

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Springer-Verlag  

    We studied the frequency and clinical value of cerebrospinal fluid flow void in 49 normal children who underwent MRI on a 0.35 T unit. T2-weighted axial SE images were retrospectively analysed to determine relative signal intensities of the fourth, third and lateral ventricles and the cerebral aqueduct, rated as high intensity, low intensity, and no signal (flow void). Flow void was seen in the fourth ventricle in 20% of children up to 3 months of age, 67% from 4 to 6 months of age, in all children aged between 7 months and 2 years and in about half of those aged more than 3 years. In cerebral aqueduct the figures were 40% up to 1 month, age, 80% at 2-3 months and 100% above 4-6 months of age, and in the third ventricle 0% up to 1 month, 60% at 2-3 months, 67% at 4-6 months, and almost 100% in above 7 months. Flow void was much more frequent at 1-6 years of age than in adults and less frequent in neonates, which may reflect the different compliance of the growing brain. © 1993 Springer-Verlag.

    DOI: 10.1007/BF00602825

    Scopus

    PubMed

    researchmap

  • Acute stroke in cats: Comparison of dynamic susceptibility-contrast MR imaging with T2- and diffusion-weighted MR imaging Reviewed

    M. Maeda, S. Itoh, H. Ide, T. Matsuda, H. Kobayashi, T. Kubota, Y. Ishii

    Radiology   189 ( 1 )   227 - 232   1993

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    PURPOSE: To evaluate the hemodynamics of acute stroke in cats by means of dynamic susceptibility-contrast magnetic resonance (MR) imaging compared with standard T2- and diffusion-weighted MR imaging. MATERIALS AND METHODS: Unilateral permanent occlusion of the middle cerebral artery was performed in 18 cats. MR imaging was performed with each method 2 hours (n = 2), 6 hours (n = 10), and 24 hours (n = 11) after occlusion. RESULTS: At every time point, dynamic MR images clearly showed ischemic regions of steady-state signal hyperintensity and areas of less dynamic decrease in signal intensity that corresponded closely to those seen on diffusion-weighted MR images. T2- weighted MR images did not reveal regions of high signal intensity 2 hours after occlusion. The measurements of relative blood volume obtained with the dynamic method were significantly lower in steady-state hyperintense ischemic areas of the affected side than those in the contralateral normal areas at 6 and 24 hours (P &lt
    .001). CONCLUSION: This dynamic method can advance the time of detection of early ischemia in comparison with T2-weighted MR imaging and provides functional information about hemodynamics not provided by other methods of MR imaging.

    DOI: 10.1148/radiology.189.1.8372198

    Scopus

    PubMed

    researchmap

  • INTRAVOXEL INCOHERENT MOTION (IVIM) MRI IN INTRACRANIAL, EXTRAAXIAL TUMORS AND CYSTS Reviewed

    M MAEDA, Y KAWAMURA, Y TAMAGAWA, T MATSUDA, S ITOH, H KIMURA, T IWASAKI, N HAYASHI, K YAMAMOTO, Y ISHII

    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY   16 ( 4 )   514 - 518   1992.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:LIPPINCOTT-RAVEN PUBL  

    Intravoxel incoherent motion MRI was used to assess six intracranial, extraaxial cysts and tumors including two epidermoids, two cystic acoustic schwannomas, and two arachnoid cysts. A maximum gradient strength of 0.7 g/cm was used simultaneously along all axes (maximum gradient b value: 445 s/mm2) and comparisons were made with an external water phantom. In epidermoid tumors the apparent diffusion coefficient (ADC) was similar to that of normal brain, thus indicating their solid nature. In acoustic schwannomas an ADC similar to the external water phantom indicated cystic components, whereas an ADC similar to brain was found in the solid portions of the tumor. The ADC of arachnoid cysts was similar to that of the water phantom, indicating their fluid nature. Due to macroscopic CSF flow, cisternal CSF showed high ADC, which enabled epidermoid tumors to be highlighted.

    Web of Science

    researchmap

  • Temporomandibular joint movement: Evaluation of protrusive splint therapy with GRASS MR imaging Reviewed

    M. Maeda, S. Itou, Y. Ishii, K. Yamamoto, Y. Kawamura, T. Matsuda, N. Hayashi, Y. Ishii

    Acta Radiologica   33 ( 5 )   410 - 413   1992

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Informa Healthcare  

    Ten temporomandibular joints (TMJs) of 5 healthy volunteers and 19 TMJs of internal derangements in 16 patients with splint therapy were examined with MR imaging. T1-weighted images were obtained only in the closed mouth position, and gradient recalled acquisition in steady state (GRASS) images were obtained in active opening and closing phases, allowing a pseudodynamic display of TMJ movement. All patients received protrusive splint treatment. the usefulness of MR imaging to assess the efficacy of splint therapy was evaluated. Corrected disk position with the splint in place was clearly demonstrated in 9 TMJs, corresponding with elimination of reciprocal clicking. Ten other TMJs of anterior disk displacement without reduction showed uncorrected disk position by the splint. This information could confirm the therapeutic efficacy, or suggest other treatment alternatives. GRASS MR imaging can provide accurate and physiologic information about disk function in initial and follow-up assessment of protrusive splint therapy © 1992 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.

    DOI: 10.1080/02841859209172023

    Scopus

    PubMed

    researchmap

  • Subtracted synthetic images in Gd-DTPA enhanced MR Reviewed

    Yuji Suto, Biray E. Caner, Yoichi Tamagawa, Tsuyoshi Matsuda, Issyu Kimura, Hirohiko Kimura, Takashi Toyama, Yasushi Ishii

    Journal of Computer Assisted Tomography   13 ( 5 )   925 - 928   1989

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    The evaluation of Gd-DTPA contrast enhancement (CE) in high intensity tissues on Tl-weighted magnetic resonance images, such as fat and bone marrow, is quite difficult. In this study, we used subtraction and subtracted color images in an attempt to show more clearly the Gd-DTPA CE. In addition, we also carried out sequential post-Gd-DTPA imaging to assess the changes in enhancement of lesions with time. Twenty patients were studied with these methods and our results are illustrated. © 1989 Raven Press, Ltd., New York.

    DOI: 10.1097/00004728-198909000-00038

    Scopus

    PubMed

    researchmap

  • Development and aging of brain midline structures: Assessment with MR imaging Reviewed

    K. Hayakawa, Y. Konishi, T. Matsuda, M. Kuriyama, K. Konishi, K. Yamashita, R. Okumura, D. Hamanaka

    Radiology   172 ( 1 )   171 - 177   1989

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    The development and aging of four brain midline structures - the pituitary gland, pons, cerebellar vermis, and corpus callosum - were studied. The dimensions and area of these structures were measured by means of midsagittal magnetic resonance imaging. The study group consisted of 94 patients newborn to 15 years old and 49 patients and seven volunteers 16-60 years old. Except for growth spurts in the 1st year and in the 10-15-year age range, the pituitary gland showed linear growth. The pons, cerebellar vermis, and corpus callosum al showed exponential growth. The cerebellar vermis showed the sharpest 1st-year growth spurt, followed by the corpus callosum and the pons. The pituitary gland showed a decrease in size in the 51-60-year age range. The corpus callosum also showed a tendency to diminish in size but to a lesser degree. There were no statistically significant declines in the size of either the pons or the cerebellar vermis in the 51-60-year age range.

    DOI: 10.1148/radiology.172.1.2740500

    Scopus

    PubMed

    researchmap

  • MR imaging of acute cerebral infarction: Experimental study with Gd-DTPA Reviewed

    K. Hayakawa, K. Yamashita, T. Matsuda, T. Miyake, H. Ito

    Radiation Medicine - Medical Imaging and Radiation Oncology   7 ( 2 )   58 - 65   1989

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Scopus

    PubMed

    researchmap

  • MR imaging of myopathy Reviewed

    Masanori Kuriyama, Katsumi Hayakawa, Yukuo Konishi, Kaoru Konishi, Masakatsu Sudo, Katsuji Nakamura, Tsuyoshi Matsuda

    Computerized Medical Imaging and Graphics   13 ( 4 )   329 - 333   1989

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Magnetic resonance imaging was performed in 8 patients with muscle disease and 6 normal controls. High intensity areas of varying dimensions were found in thigh muscles of the patients with progressive muscular dystrophy (PMD) and congenital myopathy. Shortened T, and prolonged T2 values with disease progression were characteristic. The T, values were variable and prolonged, T2 values were more characteristic of progressive muscular degeneration. The T, value may help to detect the early stage of PMD. Magnetic resonance imaging is useful in detecting the muscle lesions in PMD and essential for selection of a biopsy site. © 1989.

    DOI: 10.1016/0895-6111(89)90210-3

    Scopus

    PubMed

    researchmap

  • Scintigraphic and MRI studies in a patient with granulocytic sarcoma accompanied with CML and myelofibrosis Reviewed

    B. E. Caner, Y. Mezaki, Y. Suto, T. Toyama, T. Odori, T. Nakashima, T. Fukushima, T. Matsushita, T. Matsuda, Y. Ishii

    Radiation Medicine - Medical Imaging and Radiation Oncology   7 ( 4 )   165 - 168   1989

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Scopus

    PubMed

    researchmap

▶ display all

MISC

  • 3T MRAによる未破裂脳動脈瘤における数値流体力学指標の精度検証

    森太志, 齋藤幹人, 藤本健太郎, 久保慶高, 幸治孝裕, 小笠原邦昭, 松田豪, 上野育子, 山下典生, 佐々木真理

    日本脳ドック学会総会プログラム・抄録集   32nd   2023

  • MRIに求めるtechnical innovation 研究に携わる技術者の視点

    松田 豪

    日本放射線技術学会総会学術大会予稿集   74回   103 - 104   2018.3

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Proton MR Spectroscopy : Data Acquisition and Processing

    MATSUDA Tsuyoshi

    Japanese Journal of Magnetic Resonance in Medicine   38 ( 4 )   96 - 102   2018

     More details

    Language:Japanese   Publisher:Japanese Society for Magnetic Resonance in Medicine  

    <p> Proton magnetic resonance spectroscopy (MRS) is widely used to detect alterations in cerebral metabolite levels in various neurological disorders. Data acquisitions with a short echo-time (TE) are recommended. Subsequently, provided that time permits, it is also recommended to apply long TE with shimming/adjustment of radiofrequency pulses and careful setting of voxels of interest. In those cases where contrast agents are administered, it is preferable to perform short-TE acquisitions using non-ionic media. Advanced systems with higher static magnetic field enable the detection of low-concentration metabolites, particularly when using short TE. MRS data acquisition and processing can be performed semi-automatically; however, sufficient knowledge and skills are needed to obtain high quality spectra.</p>

    DOI: 10.2463/jjmrm.2018-1648

    CiNii Article

    researchmap

  • Brain temperature depends on degree of cerebral white matter damage in patients with subacute carbon monoxide poisoning

    S. Fujiwara, Y. Yoshioka, T. Matsuda, H. Nishimoto, A. Ogawa, K. Ogasawara, T. Beppu

    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM   37   312 - 312   2017.4

     More details

    Language:English   Publishing type:Research paper, summary (international conference)   Publisher:SAGE PUBLICATIONS INC  

    Web of Science

    researchmap

  • 7T-MRIによる血管壁イメージングを用いたレンズ核線条体動脈領域急性期ラクナ梗塞における血管壁病変の検討

    名取 達徳, 佐々木 真理, 松田 豪, 伊藤 浩平, 鳴海 新介, 宮澤 晴奈, 椛沢 宏之, 寺山 靖夫

    脳循環代謝   28 ( 1 )   160 - 160   2016.11

     More details

    Language:Japanese   Publisher:日本脳循環代謝学会  

    researchmap

  • 一酸化炭素中毒亜急性期における脳温と白質障害との関係

    藤原 俊朗, 吉岡 芳親, 松田 豪, 西本 英明, 小川 彰, 小笠原 邦昭, 別府 高明

    脳循環代謝   28 ( 1 )   176 - 176   2016.11

     More details

    Language:Japanese   Publisher:日本脳循環代謝学会  

    researchmap

  • The Safety of MR Conditional Cochlear Implant at 1.5 Tesla Magnetic Resonance Imaging System

    高橋 大輔, 小倉 明夫, 林 則夫, 清野 真也, 河合 良介, 松田 豪, 土井 司, 土橋 俊男

    日本放射線技術学会雑誌   72 ( 8 )   674 - 680   2016.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    MR装置はIngenia 1.5T Omegaを用い、人工内耳はPULSARおよびCONCERTOの2機種を用い、添付文書やパンフレットに具体的記載のない制約条件について、詳細な情報を得ることを目的として、1.5T MR装置における条件付きMRI対応人工内耳の力学的作用(吸引力およびトルク)およびインプラント磁石の減磁現象について検証した。最大磁場勾配位置における2機種の平均偏向角はそれぞれ37.3°、45.8°と機種により異なり、並進吸引力は最大でも0.26Nであった。同機種間の変動誤差は0.001〜0.003Nと結果に影響を与えないほど小さかった。最大静磁場強度位置における2機種のトルクはそれぞれ4.30N、4.66Nであった。同機種間の変動誤差は0.01〜0.03Nで、吸引力試験と同様に小さかった。インプラント磁石の磁界方向が静磁場方向に対して80°および90°の場合、磁束密度の有意な低下は認められなかった。一方、100°以上では往復運動1〜3回目から磁束密度の低下が認められ、110°および180°の場合は有意に磁束密度が低下した。低下の割合はそれぞれ100°で約5〜10%、110°で12〜20%、180ドで8〜30%であった。

    CiNii Article

    CiNii Books

    researchmap

  • 脳温計測のためのくも膜下腔DWI thermometryの開発

    藤原 俊朗, 吉岡 芳親, 松田 豪, 西本 英明, 村上 寿孝, 小川 彰, 小笠原 邦昭, 別府 高明

    日本磁気共鳴医学会雑誌   36 ( 1 )   63 - 63   2016.2

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    researchmap

  • 一酸化炭素中毒急性期・亜急性期における脳温

    藤原 俊朗, 吉岡 芳親, 松田 豪, 西本 英明, 村上 寿孝, 小川 彰, 小笠原 邦昭, 別府 高明

    脳循環代謝   27 ( 1 )   181 - 181   2015.10

     More details

    Language:Japanese   Publisher:日本脳循環代謝学会  

    researchmap

  • 条件付きMRI対応人工内耳の安全性に関する検証

    高橋 大輔, 小倉 明夫, 清野 真也, 林 則夫, 土橋 俊夫, 松田 豪, 土井 司

    日本放射線技術学会雑誌   71 ( 9 )   873 - 873   2015.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • MR信号の線形評価を目的とした正規化手法の比較

    臼田 貴俊, 金澤 裕樹, 小西 優斗, 松元 友暉, 林 裕晃, 原田 雅史, 松田 豪

    日本放射線技術学会雑誌   71 ( 9 )   935 - 935   2015.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 拡散強調画像の統計学的信号補正の比較

    小西 優斗, 金澤 裕樹, 臼田 貴俊, 松元 友暉, 林 裕晃, 原田 雅史, 松田 豪

    日本放射線技術学会雑誌   71 ( 9 )   882 - 882   2015.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Relationship between brain temperature and white matter damage in subacute carbon monoxide poisoned patients

    S. Fujiwara, Y. Yoshioka, T. Matsuda, H. Nishimoto, T. Murakami, T. Nanba, A. Ogawa, K. Ogasawara, T. Beppu

    EUROPEAN JOURNAL OF NEUROLOGY   22   630 - 630   2015.6

     More details

    Language:English   Publishing type:Research paper, summary (international conference)   Publisher:WILEY  

    Web of Science

    researchmap

  • 胎盤ポリープに対する新しい画像評価の試み 造影剤を使用しない非侵性の灌流MRIは胎盤ポリープの血流評価に有用か

    太田 可奈子, 黒川 哲司, 高橋 仁, 西島 浩二, 折坂 誠, 吉田 好雄, 金本 雅之, 藤原 康博, 木村 浩彦, 山元 龍哉, 小坂 信之, 松田 豪

    日本産科婦人科学会雑誌   67 ( 2 )   635 - 635   2015.2

     More details

    Language:Japanese   Publisher:(公社)日本産科婦人科学会  

    researchmap

  • 7Tesla高解像度MRAによる前脈絡叢動脈分枝の検討

    原田太以佑, 原田太以佑, 佐々木真理, 伊藤賢司, 上野育子, 山下典生, 樋口さとみ, 大庭英樹, 松田豪, 椛沢宏之, 寺山靖夫

    日本神経放射線学会プログラム・抄録集   44th   2015

  • 【Step up MRI 2014 進む技術、広がる臨床】 MRIのこれから 近未来への通過点 7T MRI 7T MRI装置の現状と将来展望

    松田 豪

    INNERVISION   29 ( 9 )   51 - 53   2014.8

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    7T MRI装置は、臨床研究に使用可能な汎用の商用装置としては現在最も高い静磁場強度を持った装置である。国際電気標準会議(International Electrotechnical Commision:IEC)ならびに米国食品医薬品局(Food and Drug Administration:FDA)によると、研究機として使用可能な静磁場強度の上限は1歳児以上では8Tであり、1歳児未満では4Tまでが利用可能と規定されている。日本では、ヒト用MRI装置に関しては薬事承認の基準のみが規定されており、通常操作モードでは3T以下、第一次水準管理操作モードでは4T以下のため、7T MRI装置は薬事承認対象外であり、Investigational Device Exemption(IDE)として各施設の倫理委員会による規制の下で、ヒトでの使用が可能な装置ということになる。このように、ヒト用7T MRI装置は保険請求では維持管理することのできない研究用装置であるにもかかわらず、世界では50台以上、日本においては2015年にはその約1割が稼働しようとしている。本稿では、現在7T MRI装置がどのように使われており、またどのような問題点と直面しているかを述べ、それに対するアプローチとしてどのような研究などが行われているかを簡単に述べることで、7T MRI装置における現状と研究動向、将来性について触れる。(著者抄録)

    researchmap

  • 短時間に到達時間を測定し補正したASLによるCBF値の精度向上

    金本 雅行, 藤原 康博, 木村 浩彦, 松田 豪, 安達 登志樹

    日本放射線技術学会総会学術大会予稿集   70回   171 - 171   2014.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • pseudo continuous ASLを用いた脳血流画像におけるスピンの到達遅延による影響の低減について

    藤原 康博, 金本 雅之, 木村 浩彦, 松田 豪, 安達 登志樹

    日本放射線技術学会総会学術大会予稿集   70回   267 - 267   2014.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 7 Tesla高解像度MRAにおける前交通動脈穿通枝の描出能の検討

    原田太以佑, 佐藤由衣子, 南波孝昌, 幸司孝裕, 別府高明, 松田豪, 椛沢宏之, 山下典生, 上野育子, 工藤與亮, 小笠原邦昭, 佐々木真理

    日本神経放射線学会プログラム・抄録集   43rd   2014

  • Analysis of Accidents for Magnetically Induced Displacement of the Large Ferromagnetic Material in Magnetic Resonance Systems

    YAMATANI Yuya, DOI Tsukasa, UEYAMA Tsuyoshi, NISHIKI Shigeo, OGURA Akio, KAWAMITSU Hideaki, TSUCHIHASHI Toshio, OKUAKI Tomoyuki, MATSUDA Tsuyoshi

    Japanese Journal of Radiological Technology   69 ( 1 )   99 - 108   2013.1

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    To improve magnetic resonance (MR) safety, we surveyed the accidents caused by large ferromagnetic materials brought into MR systems accidentally. We sent a questionnaire to 700 Japanese medical institutions and received 405 valid responses (58%). A total of 97 accidents in 77 institutions were observed and we analyzed them regarding incidental rate, the detail situation and environmental factors. The mean accident rate of each institute was 0.7/100,000 examinations, which was widely distributed (0–25.6/100,000) depending on the institute. In this survey, relatively small institutes with less than 500 beds tend to have these accidents more frequently (p<0.01). The institutes in which daily MR examination counts are more than 10 patients have fewer accidents than those with less than 10 daily examinations. The institutes with 6–10 MR examinations daily have significantly more accidents than that with more than 10 daily MR examinations (p<0.01). The main mental factors of the accidents were considered to be “prejudice” and “carelessness” but some advocate “ignorance.” Though we could not find significant reduction in the institutes that have lectures and training for MR safety, we should continue lectures and training for MR safety to reduce accidents due to “ignorance.”

    DOI: 10.6009/jjrt.2013_JSRT_69.1.99

    CiNii Article

    CiNii Books

    researchmap

  • Relationship between MR Safety Management and MR Technological Specialists

    UEYAMA Tsuyoshi, YAMATANI Yuya, DOI Tsukasa, NISHIKI Shigeo, OGURA Akio, KAWAMITSU Hideaki, TSUCHIHASHI Toshio, OKUAKI Tomoyuki, MATSUDA Tsuyoshi

    日本磁気共鳴医学会雑誌   32 ( 4 )   122 - 131   2012.11

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    MR専門技術者の認定取得前後で安全に関する意識の変化、認定者が在籍していない施設との吸着事故の件数の違いを調べるためにアンケートを実施した。MR専門技術者が在籍している施設は、在籍していない施設に比べ1日あたり約2倍の検査をこなしているが、吸引事故の発生率は在籍していない施設に比べ低かった。スタッフの充実度や体外金属の確認の実施に関しては認定者の在籍と因果関係はなく、各施設において適切な手順が設けられていたが、事故の多くは思い込みや確認不足であり、その背景には業務多忙やスタッフ間の連携ミスなど、普段よく耳にする医療ミスの発生原因と大きく変わらなかった。知識不足・認識不足は教育によって改善されると考えられるが、確認不足は施設毎に労働条件や施設環境が異なりさまざまな要因を抱えていた。

    CiNii Article

    CiNii Books

    researchmap

  • MR検査における大型強磁性体吸引事故の原因分析

    山谷 裕哉, 上山 毅, 土井 司, 錦 成郎, 小倉 明夫, 川光 秀昭, 土橋 俊男, 奥秋 知幸, 松田 豪, MRI装置の安全管理に関するアンケートの分析研究班

    日本放射線技術学会雑誌   68 ( 9 )   1181 - 1181   2012.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 7テスラMRIによる脳神経画像診断の新しい展開

    佐々木 真理, 工藤 與亮, 上野 育子, 椛沢 宏之, 松田 豪

    BRAIN and NERVE: 神経研究の進歩   64 ( 9 )   1057 - 1062   2012.9

     More details

    Language:Japanese   Publisher:(株)医学書院  

    7TMRIは高い信号雑音比を活かして脳神経領域の超高精細形態画像を得ることができる他、強い磁化率効果を利用して、T2強調画像、磁化率強調画像の大幅なコントラスト向上や、functional MRIの精度向上が可能となる。また、T1の延長はMRAやarterial spin labelingの大幅な画質向上や造影効果の向上に寄与し、化学シフトの増加はMR spectroscopyの分離能向上をもたらす。7TMRIの特徴・画像・将来について述べた。

    researchmap

  • 3Tesla MRIによる脳内抗酸化物質の非侵襲的測定の検討

    原田 雅史, 中山 千明, 久保 均, 能勢 歩美, 大塚 秀樹, 松田 豪

    日本医学放射線学会学術集会抄録集   71回   S281 - S282   2012.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 前立腺3T-MR Spectroscopy without endorectal surface coil using MLEV-PRESS sequenceの検討

    吉廻 毅, 原 真司, 内田 幸司, 北垣 一, 洲村 正裕, 井川 幹夫, 楫 靖, 松田 豪, 鵜池 充宏

    日本医学放射線学会学術集会抄録集   71回   S324 - S324   2012.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • アーチファクトを再考する(より良い撮影技術を求めて(その111),第58回放射線撮影分科会報告)

    松田 豪, 藤田 功

    放射線撮影分科会誌   59 ( 0 )   64 - 64   2012

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.59.0_64

    CiNii Article

    CiNii Books

    researchmap

  • MR装置の安全管理に関する実態調査の報告

    土井 司, 山谷 裕哉, 上山 毅, 小倉 明夫, 錦 成郎, 川光 秀昭, 土橋 俊男, 松田 豪, 奥秋 知幸, 熊代 正行, MRI装置の安全管理に関する実態調査班

    日本放射線技術学会雑誌   67 ( 9 )   1117 - 1118   2011.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • An Investigative Report Concerning Safety and Management in the Magnetic Resonance Environment : There Are More Accidents than Expected

    DOI Tsukasa, YAMATANI Yuya, UEYAMA Tsuyoshi, NISHIKI Shigeo, OGURA Akio, KAWAMITSU Hideaki, TSUCHIHASHI Toshio, OKUAKI Tomoyuki, MATSUDA Tsuyoshi, KUMASHIRO Masayuki

    Japanese Journal of Radiological Technology   67 ( 8 )   895 - 904   2011.8

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    Using a questionnaire, we surveyed 2,500 facilities in Japan to clarify medical accidents concerning the magnetic resonance device and its environment. Data derived from 1,319 valid responses (52.8%), allowed us to analyze the situation of (or the reason for) the occurrence of the accidents and their environmental factors. Five hundred and nine facilities (39% of all facilities) had the experience of magnetically induced displacement of the large ferromagnetic material. Intravenous (I.V.) drip stands were involved the largest number of them: 31% (228 cases). Oxygen bottles had the second largest number of incidents: 20%. There were also many incidents involving various materials brought in by non-medical staff (e.g. stepladder for construction). About 20% of the accidents occurred outside of working hours. Patients in 12% of the facilities (154 facilities) experienced burns. In 39 of the cases, burns were received to the inside of the thighs. In 38 of the cases, patients received burns from an electrical cable touching the skin. There were also frequent incidents of burning regarding the boa. We received reports of burns and pain from the halo vest even though it’s required to be worn for MR safety. Regarding incidents of contraindications, 280 patients with pacemakers were brought into the magnetic resonance (MR) inspection room. Twelve percent of the facilities experienced natural quench. Lack of training for the staff who introduce and operate high magnetic field devices are considered involving frequently occurring accidents of attractions and burns at hospitals with over 500 beds caused by carrying in materials.

    DOI: 10.6009/jjrt.67.895

    CiNii Article

    CiNii Books

    researchmap

  • 【Step up MRI 2011-多様化するニーズにどう応えるか-】 領域別に見る臨床に生かせる機能情報とは 下腹部領域 前立腺 MRSを中心に

    吉廻 毅, 原 真司, 内田 幸司, 北垣 一, 州村 正裕, 井川 幹夫, 楫 靖, 松田 豪, 鵜池 充宏

    INNERVISION   26 ( 9 )   18 - 19   2011.8

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    前立腺がんは、罹患率が上昇している疾患であり、その予後はさまざまである。また、現在、いろいろな治療法が存在しているため、治療前に正確に前立腺がんの存在部位、進行度を把握し、予後を推測し、治療法を選ぶことが重要となっている。しかし、前立腺がんのMRIは、施設、機種、読影医の差により、検査情報が異なるものになってしまうことがあるので、その有用性はいまだに一定していない。そこで、MRIの欠点を補い、非侵襲的、客観的に生体内の代謝産物情報を提供できるMRスペクトロスコピー(MRS)に期待が寄せられている。だが、国内ではソフトやコイルの問題があり、前立腺MRSの普及はいまだ不十分と思われる。本稿では、現在の前立腺MRSの基本的有効性を概説し、3T装置によるMRSへの期待について述べる。(著者抄録)

    researchmap

  • ASLを用いた腎臓の灌流画像の至適撮像条件の検討

    藤原 康博, 木村 浩彦, 松田 豪, 藤本 真一, 丸山 力哉, 石田 智一, 安達 登志樹

    日本放射線技術学会総会学術大会予稿集   67回   278 - 278   2011.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 巻頭言

    松田 豪

    放射線撮影分科会誌   57 ( 0 )   2 - 2   2011

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.57.0_2

    CiNii Article

    CiNii Books

    researchmap

  • アーチファクトを再考する(ワークショップ-より良い撮影技術を求めて(その106)-,テーマC:MR検査におけるアーチファクト)

    松田 豪, 錦 成郎

    放射線撮影分科会誌   56 ( 0 )   44 - 44   2011

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.56.0_44

    CiNii Article

    CiNii Books

    researchmap

  • 臨床用3T-MRIによる13C標識Glucoseの脳内代謝の観察

    原田 雅史, 久保 均, 松田 豪

    安定同位体と生体ガス: 医学応用   2 ( 1 )   75 - 76   2010.11

     More details

    Language:Japanese   Publisher:日本安定同位体・生体ガス医学応用学会  

    researchmap

  • T2補正による脂肪量測定MRSの妥当性の検討

    橋本 亜樹生, 中村 智哉, 川又 郁夫, 松田 豪

    日本放射線技術学会雑誌   66 ( 9 )   1100 - 1101   2010.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • NAFLDにおける1H-Magnetic Resonance Spectroscopyを用いた肝脂肪量と内臓・皮下脂肪の関係

    白石 光一, 永田 順子, 広瀬 俊治, 丸野 敦子, 矢崎 利典, 井原 憲一, 長田 成彦, 松崎 松平, 松田 豪

    アルコールと医学生物学   29   130 - 135   2010.4

     More details

    Language:Japanese   Publisher:(株)響文社  

    超音波で診断された非アルコール性脂肪性肝疾患(NAFLD)34例(男18例、女性16例、平均55.6歳)を対象に、1H-Magnetic Resonance Spectroscopy(1H-MRS)を用い、肝脂肪量を測定し、皮下・内臓脂肪量およびアディポサイトカインと比較検討した。NAFLD全症例におけるBMIは26.4±3.8のうち25以下は29.4%と肥満症を呈さない症例が認められた。肝臓脂肪/水比は14.6±13.6%で0.04〜49.11%と幅広く分散し、内臓脂肪136.4±56.9cm2、皮下脂肪200.6±86.8cm2であった。肝臓脂肪/水比との相関は年齢r=-0.47、BMIr=0.31、内臓脂肪r=0.33、皮下脂肪r=0.21、ASTr=0.55、ALTr=0.71であった。アディポネクチン10.8±9.0(20例)、高分子アディポネクチン6.1±6.7、レプチン11.8±13.2で肝臓脂肪/水比と相関傾向は認められなかった。内臓脂肪と皮下脂肪の全脂肪面積に対する面積比の検討を行い、性別による検討では男性においてBMIr=0.191、内臓脂肪r=0.423、皮下脂肪r=0.507と内臓・皮下脂肪量と肝臓脂肪量に有意な関係を認めた。一方、女性ではBMIr=0.328、内臓脂肪r=0.060、皮下脂肪r=0.261と明らかな相関は示さなかった。

    researchmap

  • CASLとFAIRにおけるTransit効果およびCBF定量性についての3TMRIによる比較評価

    岩永 崇, 原田 雅史, 久保 均, 大西 恭平, 椛沢 宏之, 松田 豪, 西谷 弘

    日本放射線技術学会総会学術大会予稿集   66回   186 - 186   2010.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 肝MRI検査におけるProton MRSを用いた水と脂肪の測定シーケンスの有用性

    林 則夫, 大野 直樹, 宮地 利明, 松田 豪, 山本 友行, 龍 泰治, 松井 修

    日本放射線技術学会総会学術大会予稿集   66回   248 - 248   2010.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • pseudo CASLによる局所脳血流量の短時間測定

    藤原 康博, 木村 浩彦, 松田 豪, 福島 哲弥, 石田 智一, 東村 享治

    日本放射線技術学会総会学術大会予稿集   66回   186 - 186   2010.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 3T MRI装置Signa HDx 3Tの腹部への臨床応用の現状

    小林 聡, 蒲田 敏文, 松井 修, 香田 渉, 龍 泰治, 南 哲弥, 小坂 一斗, 河原 和博, 松浦 幸広, 林 則夫, 清水 俊博, 松岡 慎一, 松田 豪

    映像情報Medical   41 ( 14 )   62 - 67   2009.12

  • AVM周囲脳循環動態と脳温 SPECTおよびMRSによる検討

    井上 敬, 清水 宏明, 藤原 悟, 冨永 悌二, 松田 豪, 吉岡 芳親

    脳循環代謝   21 ( 1 )   112 - 112   2009.11

     More details

    Language:Japanese   Publisher:日本脳循環代謝学会  

    J-GLOBAL

    researchmap

  • 輝く放射線医療 今そして未来 人と技術のハーモニー 診断 産学協同体制で躍進する放射線医療

    松田 豪

    日本医学放射線学会学術集会抄録集   68回   S48 - S48   2009.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 上腹部検査の新たな展開(より良い撮影技術を求めて(その93),第51回放射線撮影分科会報告)

    松田 豪, 藤田 功

    放射線撮影分科会誌   52 ( 0 )   67 - 67   2009

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.52.0_67

    CiNii Article

    CiNii Books

    researchmap

  • AVM周囲脳血流と脳温:SPECTおよびMRSによる検討

    井上敬, 清水宏明, 藤原悟, 冨永悌二, 松田豪, 吉岡芳親

    日本脳神経外科学会総会抄録集(CD-ROM)   68th   2009

  • High Field MRI and Safety

    DOI Tsukasa, Matsuda Tsuyoshi

    Japanese Journal of Radiological Technology   64 ( 12 )   1491 - 1491   2008.12

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology (JSRT)  

    DOI: 10.6009/jjrt.64.1491

    CiNii Article

    CiNii Books

    researchmap

  • Safety of 3T-MRI

    KAWAMITSU Hideaki, Matsuda Tsuyoshi

    Japanese Journal of Radiological Technology   64 ( 12 )   1575 - 1599   2008.12

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology (JSRT)  

    DOI: 10.6009/jjrt.64.1575

    CiNii Article

    CiNii Books

    researchmap

  • Suppression of CSF Artifact in Fast FLAIR Sequence at 3.0 Tesla

    FUJIWARA Yasuhiro, ISHIMORI Yoshiyuki, YAMAGUCHI Isao, MATSUDA Tsuyoshi, MIYATI Tosiaki, KIMURA Hirohiko

    Japanese Journal of Radiological Technology   64 ( 12 )   1513 - 1521   2008.12

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology (JSRT)  

    The purpose of this study was to suppress CSF flow artifacts in the fast FLAIR sequence at 3.0T MRI. We investigated the influence of thickness of the inversion pulse in the sequence on the high-intensity CSF flow artifacts based on the flow phantom and in-vivo studies at 1.5T and 3.0T. Results demonstrated that CSF flow artifacts at 3.0T were clearly stronger than at as 1.5T. Moreover, 3.0T was influenced by the crosstalk between each inversion pulse compared with 1.5T. The optimal setting of inversion pulse for two interleaving acquisitions for fast FLAIR imaging at 3.0T was approximately 1.5 fold on the basis of sum of slice thickness and slice gap. The appropriate setting of thickness of inversion pulse in fast FLAIR imaging reduces the incidence of CSF flow artifacts at 3.0T.

    DOI: 10.6009/jjrt.64.1513

    CiNii Article

    CiNii Books

    researchmap

  • MRSによる脳温測定の可能性

    井上 敬, 清水 宏明, 藤原 悟, 冨永 悌二, 松田 豪, 吉岡 芳親

    日本脳神経外科学会総会CD-ROM抄録集   67回   2J - 01   2008.10

     More details

    Language:Japanese   Publisher:(一社)日本脳神経外科学会  

    J-GLOBAL

    researchmap

  • 7 Proton MRSを用いた水と脂肪の測定シーケンスの開発(MR検査 肝臓-機能,第36回日本放射線技術学会秋季学術大会)

    松田 豪

    日本放射線技術學會雜誌   64 ( 9 )   1068 - 1068   2008.9

     More details

    Language:Japanese   Publisher:公益社団法人日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

  • Proton MRSを用いた水と脂肪の測定シーケンスの開発

    松田 豪

    日本放射線技術学会雑誌   64 ( 9 )   1068 - 1068   2008.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • MRIによる脳循環予備能評価 OEF測定の可能性

    井上 敬, 清水 宏明, 社本 博, 藤原 悟, 冨永 悌二, 松田 豪

    脳卒中   30 ( 2 )   340 - 340   2008.3

     More details

    Language:Japanese   Publisher:(一社)日本脳卒中学会  

    J-GLOBAL

    researchmap

  • 3T Editing proton MRSによる脳内GABA測定の再現性とWest症候群におけるACTH療法前後での検討

    原田 雅史, 原田 太平, 西谷 弘, 久保 均, 松田 豪

    日本医学放射線学会学術集会抄録集   67回   S196 - S196   2008.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 正常人脳γ-アミノ酪酸(GABA)の年齢変化についての検討 voxel内組織比率を用いた解析

    木村 浩彦, 豊岡 真理子, 小坂 浩隆, 村田 哲人, 松田 豪

    日本医学放射線学会学術集会抄録集   67回   S293 - S293   2008.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 3テスラT2*強調画像による磁化率効果の定量化と脳虚血評価の検討

    原田 雅史, 森田 奈緒美, 西谷 弘, 松崎 健司, 竹内 麻由美, 久保 均, 松田 豪

    日本医学放射線学会学術集会抄録集   67回   S196 - S197   2008.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • Cerebral perfusion measurements using continuous arterial spin labeling(CASL) : Clinical application and technical development

    木村 浩彦, 土田 龍郎, 植松 秀昌, 竹内 浩明, 椛沢 宏之, 松田 豪, 岡沢 秀彦, 藤林 康久

    生体画像医学の統合研究プログラム 福井大学21世紀COEプログラム   57 - 68   2008

     More details

  • Reduction of Vascular Artifact on T1-weighted Images of the Brain by Using Three-dimensional Double IR Fast Spoiled Gradient Echo Recalled Acquisition in the Steady State (FSPGR) at 3.0 Tesla

    FUJIWARA Yasuhiro, MATSUDA Tsuyoshi, ISHIMORI Yoshiyuki, YAMAGUCHI Isao, HAYASHI Hiroyuki, OOKOSHI Yusuke, OOTANI Yuriko, MIYATI Tosiaki, KIMURA Hirohiko

    Japanese Journal of Radiological Technology   63 ( 11 )   1239 - 1245   2007.11

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology (JSRT)  

    The purpose of this study was to decrease vascular artifacts caused by the in-flow effect in three-dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady state (3D IR FSPGR) at 3.0 Tesla. We developed 3D double IR FSPGR and investigated the signal characteristics of the new sequence. The 3D double IR FSPGR sequence uses two inversion pulses, the first for obtaining tissue contrast and the second for nulling vascular signal, which is applied at the time of the first IR period at the neck region. We have optimized scan parameters based on both phantom and <i>in-vivo</i> study. As a result, optimized parameters (1st TI=700 ms, 2nd TI=400 ms) successfully have produced much less vessel signal at reduction than conventional 3D IR FSPGR over a wide imaging range, while preserving the signal-to-noise ratio (SNR) and gray/white matter contrast. Moreover, the decreased artifact was also confirmed by visual inspection of the images obtained <i>in vivo</i> using those parameters. Thus, 3D double IR FSPGR was a useful sequence for the acquisition of T1-weighted images at 3.0 Tesla. (Article in Japanese)

    DOI: 10.6009/jjrt.63.1239

    CiNii Article

    CiNii Books

    researchmap

  • t-PAを有効かつ安全に使うための超急性期脳虚血に対するFAIRとCSIの有用性について 1.5T MRIでの評価

    木村 輝雄, 遠藤 純男, 恩田 清, 桧前 薫, 宮川 照夫, 山崎 一徳, 新井 弘之, 松田 豪, 橋本 政明

    脳循環代謝   19 ( 2 )   81 - 81   2007.10

     More details

    Language:Japanese   Publisher:日本脳循環代謝学会  

    researchmap

  • H-MRS,IMP-SPECTを用いた特発性正常圧水頭症(iNPH)の脳循環代謝解析

    木村 輝雄, 遠藤 純男, 宮川 照夫, 山崎 一徳, 新井 弘之, 和田 始, 川崎 和凡, 橋本 政明, 松田 豪

    脳循環代謝   19 ( 2 )   128 - 128   2007.10

     More details

    Language:Japanese   Publisher:日本脳循環代謝学会  

    researchmap

  • MRIによるOEF測定

    井上 敬, 清水 宏明, 社本 博, 藤原 悟, 冨永 悌二, 松田 豪

    脳循環代謝   19 ( 2 )   87 - 87   2007.10

     More details

    Language:Japanese   Publisher:日本脳循環代謝学会  

    J-GLOBAL

    researchmap

  • New Method of Determining Regional Fat Fraction with Modulus and Real Multiple Gradient-echo (MRM-GRE)

    ARAI Nobuyuki, MIYATI Tosiaki, MATSUNAGA Sayoko, MOTONO Yuko, UEDA Yuu, KASAI Harumasa, SUZUKI Yuriko, MATSUDA Tsuyoshi

    Japanese Journal of Radiological Technology   63 ( 3 )   312 - 318   2007.3

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology (JSRT)  

    We devised a method of analyzing a regional fat fraction using a modulus and real multiple gradient-echo (MRM-GRE) 4-7 echo Dixon sequence. The regional fat fraction was calculated with a theoretically fitted signal-intensity curve for multiple GRE images at each echo time (i.e., 4-7 echoes.) on a 1.5 Tesla MRI to correct T2* decay and phase cycling. Then the real image of the first echo was used to differentiate between the areas above and below the 50 percent fat fraction. To eliminate the T1-effect, the flip angle was set at 12 degrees. Fat fractions of the phantom with MRM-GRE were compared with those using conventional double-GRE and other MRI techniques. Fat fractions of liver and spinal bone marrow in healthy volunteers were determined during a breath-hold. The fat fraction of the phantom obtained by the MRM-GRE method tended to agree with the actual fat fraction. On the other hand, in both the phantom and in healthy volunteers, the double-GRE was underestimated owing to T2* decay. The MRM-GRE method enables simple, accurate analysis of the regional fat fraction.

    DOI: 10.6009/jjrt.63.312

    CiNii Article

    CiNii Books

    researchmap

  • 脳機能を解明するためのMR検査技術(ワークショップ-よりよい撮影技術を求めて(その86)-,テーマC:MR「脳の機能描出を科学する」)

    松田 豪, 錦 成郎

    放射線撮影分科会誌   48 ( 0 )   37 - 37   2007

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.48.0_37

    CiNii Article

    CiNii Books

    researchmap

  • 脳機能を解明するためのMR検査技術(ワークショップ-よりよい撮影技術を求めて(その86)-,第48回撮影分科会報告)

    錦 成郎, 松田 豪

    放射線撮影分科会誌   49 ( 0 )   64 - 64   2007

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.49.0_64

    CiNii Article

    CiNii Books

    researchmap

  • 脳疾患のミクロな世界を解明する最新の検査技術(ワークショップ-よりよい撮影技術を求めて(その82)-,第47回放射線撮影分科会報告)

    錦 成郎, 松田 豪

    放射線撮影分科会誌   48 ( 0 )   54 - 54   2007

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.48.0_54

    CiNii Article

    CiNii Books

    researchmap

  • Optimization of Three-dimensional Triple IR Fast Spoiled Gradient Recalled Acquisition in the Steady State (FSPGR) to Decrease Vascular Artifact at 3.0 Tesla

    FUJIWARA Yasuhiro, MATSUDA Tsuyoshi, ISHIMORI Yoshiyuki, YAMADA Kazuhiro, FUKUYA Yuko, YAMAGUCHI Isao, KIMURA Hirohiko, MIYATI Tosiaki

    Japanese Journal of Radiological Technology   62 ( 11 )   1560 - 1565   2006.11

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology (JSRT)  

    The purpose of this study was to decrease vascular artifacts caused by the in-flow effect in three-dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady state (3D IR FSPGR) at 3.0 Tesla. We developed 3D triple IR (3IR) FSPGR and examined the signal characteristics of the new sequence. We have optimized scan parameters based on simulation, phantom, and <i>in-vivo</i> studies. As a result, optimized parameters (1st TI=600 ms, 3rd TI=500 ms) successfully have produced the vessel signal at more than 40% reduction, while gray-white matter contrast was preserved. Moreover, the reduced artifact was also confirmed by visual inspection of the <i>in-vivo</i> images for which this condition was used. Thus, 3D 3IR FSPGR was a useful sequence for the acquisition of T1-weighted images at 3.0 Tesla.

    DOI: 10.6009/jjrt.62.1560

    CiNii Article

    CiNii Books

    researchmap

  • Phase Mask Processing in Susceptibility-weighted Imaging : Effects of Hamming Window Size

    KANBARA Yoshiyuki, SASAKI Makoto, MATSUMURA Yutaka, ABE Sumiko, MATSUDA Tsuyoshi, TSUKAMOTO Tetsuji, EHARA Shigeru

    日本磁気共鳴医学会雑誌   26 ( 1 )   58 - 60   2006.1

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    位相マスク処理におけるHamming窓サイズの影響について検討し,磁化率強調画像の画質改善を試みた.健常ボランティア11例,脳血管障害患者2例を対象とした.位相マスク処理画像では,処理をしない画像に比べ,生理的鉄沈着部位,髄質静脈,深部静脈における位相変化に基づく信号低下が強調された.小さなHamming窓では,基底核,皮質の信号低下がとらえられた.中程度のHamming窓では髄質静脈,深部静脈の信号低下が強調され,MinIP画壕における静脈の描出能が向上した.大きなHamming窓では,比較的太い深部静脈の信号低下は不明瞭となり,髄質静脈の低信号のみが強調された.静脈奇形では,中程度のHamming窓で位相マスク処理をすることで,拡張した髄質静脈や幹静脈のコントラストが改善した.微小出血においては,病変の視認性はむしろ低下した

    CiNii Article

    CiNii Books

    researchmap

  • Susceptibility-weighted Imaging at 3 Tesla : Clinical Applications in Multiple Sclerosis

    SASAKI Makoto, KANBARA Yoshiyuki, SHIBATA Eri, TAKAHASHI Satoshi, TAKAHASHI Junko, FUKAURA Hikoaki, ABE Sumiko, MATSUDA Tsuyoshi, TSUKAMOTO Tetsuji, EHARA Shigeru

    日本磁気共鳴医学会雑誌   26 ( 1 )   61 - 63   2006.1

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    3TMRIによる磁化率強調画像(SWI)を用いて,多発性硬化症における磁化率効果に起因する画像所見について検討した.多発性硬化症患者8例を対象とした.位相マスク処理によって深部静脈,髄質静脈の描出能が大幅に向上した.3TMRIでは従来描出できなかった局所位相シフトに基づく小病変を検出できた.8例中7例で髄質静脈が脱髄斑の中央を貫いている様子が良好に観察した.8例中6例では一部の脱髄斑内における髄質静脈の拡張を認め,病変の活動性を反映している可能性が示唆された.T2WIで高信号を呈する脱髄斑は,SWIでは多彩な所見を呈し,4パターンに分類できた.T2WIで異常信号を呈さない白質,灰白質においてSWIで低信号を呈する病変をそれぞれ8例中4例,8例中5例で認めた.多発性硬化症における脱髄病変の検出や病態解析に有望であることが示唆された

    CiNii Article

    CiNii Books

    researchmap

  • 脳疾患のミクロな世界を解明する最新の検査技術(ワークショップ-よりよい撮影技術を求めて(その82)-,テーマA:一般「脳のミクロな世界を解明する」)

    錦 成郎, 松田 豪

    放射線撮影分科会誌   47 ( 0 )   5 - 5   2006

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.47.0_5

    CiNii Article

    CiNii Books

    researchmap

  • 拡散強調画像を臨床に生かす撮像技術(ワークショップ-よりよい撮影技術を求めて(その81),テーマC : MR「拡散強調を科学する」)

    久保 均, 松田 豪

    放射線撮影分科会誌   46 ( 0 )   39 - 39   2006

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.46.0_39

    CiNii Article

    CiNii Books

    researchmap

  • 拡散強調画像を科学する(ワークショップ-よりよい撮影技術を求めて(その81)-,第46回撮影分科会報告)

    松田 豪

    放射線撮影分科会誌   47 ( 0 )   50 - 50   2006

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.47.0_50

    CiNii Article

    CiNii Books

    researchmap

  • 画像診断ABC 機器の進歩とその利用 機器 MRI機器 最近の進歩 新しい利用法とその展開

    木村 浩彦, 越元 佳郎, 植松 秀昌, 伊藤 春海, 小坂 浩隆, 山口 功, 藤原 康博, 椛沢 宏之, 松田 豪

    医薬ジャーナル   41 ( 10 )   np1 - np7   2005.10

     More details

    Language:Japanese   Publisher:(株)医薬ジャーナル社  

    最近のMRI(magnetic resonance imaging)機器進歩の最たるものは,高磁場化である.高磁場化に伴い得られたS/Nが改善し,多断面化,高分解能化が得られる.機能検査への応用として,fundctional MRI,perfusion MR,DTI and Fiber tracking,MR spectroscopyのそれぞれについて,高磁場の利点をいかした最近の展開を紹介した(著者抄録)

    CiNii Article

    CiNii Books

    researchmap

  • 【超高磁場MRI装置の使用経験】 MR Perfusion imaging: 3T Arterial Spin Labeling(ASL)の理論と実際

    木村 浩彦, 越元 佳郎, 植松 秀昌, 伊藤 春海, 石森 佳幸, 藤原 康博, 椛沢 宏之, 松田 豪

    映像情報Medical   37 ( 10 )   993,953 - 997,953   2005.9

  • Clinical Development of Measurement for the Neurotransmitter Agent Using 3 Tesla MRI

    HARADA Masafumi, KUBO Hitoshi, SAKAMA Minoru, NISHITANI Hiromu, MATSUDA Tsuyoshi

    IEICE technical report. ME and bio cybernetics   105 ( 221 )   5 - 6   2005.7

     More details

    Language:Japanese   Publisher:The Institute of Electronics, Information and Communication Engineers  

    The method to measure the neurotransimtter agent was developed for clinical 3Tesla MRI.

    CiNii Article

    CiNii Books

    researchmap

  • 臨床イメージングの現状 MRIとCTを中心に

    松田 豪

    日本獣医学会学術集会講演要旨集   139回   93 - 93   2005.3

     More details

    Language:Japanese   Publisher:(公社)日本獣医学会  

    researchmap

  • 臨床用3TMRIによる脳内GABA濃度の検出法の開発と有用性

    原田 雅史, 久保 均, 湊 雅子, 西谷 弘, 松田 豪

    日本医学放射線学会学術集会抄録集   64回   S148 - S149   2005.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 前立腺の3テスラProton MRS PSA高値症例での検討

    楫 靖, 黒田 輝, 岡田 知久, 松岡 雄一郎, 原 勲, 川喜田 睦司, 松田 豪, 杉村 和朗

    日本医学放射線学会学術集会抄録集   64回   S217 - S217   2005.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 脳組織における dual component T2 analysis(MR検査 頭頸部, 一般研究発表予稿集, 日本放射線技術学会第33回秋季学術大会)

    杉山 雄一郎, 堀井 実, 橋本 亜樹生, 山田 晋也, 松田 豪

    日本放射線技術学会雑誌   61 ( 9 )   1302 - 1303   2005

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00004028526

    CiNii Article

    researchmap

  • 3.0 T MR装置による<sup>1</sup>Hデカップリング<sup>13</sup>C‐MRSの安全性評価―臨床応用を目指して―

    斎藤もよこ, 松田豪, TROPP J, 中井敏晴, 犬伏俊郎

    日本磁気共鳴医学会雑誌   24 ( Supplement(Sept) )   315   2004.9

     More details

    Language:Japanese  

    J-GLOBAL

    researchmap

  • In Vivo Proton Decoupled <sup>13</sup>C MRSの基礎検討

    松田豪, 斎藤もよこ, TROPP J, 犬伏俊郎, 中井敏晴

    日本磁気共鳴医学会雑誌   24 ( Supplement(Sept) )   315   2004.9

     More details

    Language:Japanese  

    J-GLOBAL

    researchmap

  • スライス選択水励起法を用いた脂肪抑制効果の検討 CHESS法との比較

    土橋 俊男, 松村 善雄, 新田 武史, 吉澤 賢史, 三代 繁幸, 根津 伸弘, 松田 豪

    日本放射線技術学会雑誌   60 ( 9 )   1262 - 1262   2004.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • MRIを使用した脳における細胞内細胞外水分量の測定及び画像化

    山田 晋也, 松田 豪, 杉山 雄一郎, Stefan Bluml, McComb Gordon

    小児の脳神経   29 ( 2 )   134 - 134   2004.4

     More details

    Language:Japanese   Publisher:(一社)日本小児神経外科学会  

    researchmap

  • Imaging Techniques at Ultra High Magnetic Field

    ISHIMORI Yoshiyuki, FUJIWARA Yasuhiro, KITA Akinobu, YAMADA Kazuhiro, KIMURA Hirohiko, MATSUDA Tsuyoshi, KABASAWA Hiroyuki, FUJIBAYASHI Yasuhisa, YONEKURA Yoshiharu

    日本磁気共鳴医学会雑誌   24 ( 1 )   4 - 15   2004.2

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    CiNii Article

    CiNii Books

    researchmap

  • spectral spatial RF併用spiral SPGRの骨盤2D MRDSAへの応用

    吉廻 毅, 内田 幸司, 梶谷 尊郁, 土江 洋二, 山本 伸子, 北垣 一, 鵜池 充宏, 松田 豪

    日本医学放射線学会雑誌   64 ( 2 )   S301 - S301   2004.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 放射線技術学と放射線技術学会

    松田 豪

    放射線撮影分科会誌   43 ( 0 )   1 - 1   2004

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.43.0_1

    CiNii Article

    CiNii Books

    researchmap

  • 309 スライス選択水励起法を用いた脂肪抑制効果の検討 : GHESS法との比較(MR検査 基礎 脂肪制御・ステディーステイトイメージング)(一般研究発表)(第32回秋季学術大会)

    土橋 俊男, 松村 善雄, 新田 武史, 吉澤 賢史, 三代 繁幸, 根津 伸弘, 松田 豪

    日本放射線技術学会雑誌   60 ( 9 )   1262 - 1262   2004

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003174562

    CiNii Article

    researchmap

  • Fundamental Study of Magnetization Transfer Contrast (MTC) Effect : Optimization of MT Pulse Condition Using Experimental Phantom

    KAWATA HIDEMICHI, NISHIMURA HIROSHI, NAGATA SYUJI, MATSUDA TSUYOSHI, TAKADA KIMIYOSHI, HAYABUCHI NAOFUMI

    Japanese Journal of Radiological Technology   60 ( 10 )   1437 - 1443   2004

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    Magnetization transfer contrast (MTC) was evaluated by changing the off-set frequency and pulse intensity of MTC with the spoiled gradient echo (SPGR) sequence (T2^*-weighted image) using an experimental phantom that included olive oil, protein, fiber, collagen, and pure water. The intensity of pure water reached a constant level just above the off-set frequency (1200 Hz)regardless of MT pulse power. The contrast-to-noise ratio(CNR)in each of the phantom materials was maximal at the MT pulse power of 2500 degrees (equivalent flip angle). The CNR and image noise obtained by body coil were inferior to those obtained with an extremity coil. In clinical application, the MTC effect on chondrosarcoma was higher(MT ratio, ROI-1:0.448, ROI-2:0.382)than those of other cases in this study. Since the image contrast was improved between the malignant fibrous histiocytoma(MFH, MT ratio, ROI-1:0.282, ROI-2:0.289)and peripheral tissues, extraskeletal extension could be observed more easily than without MTC imaging. In conclusion, the effects of MTC might be in providing useful information, in presuming composed tissues, differential diagnoses, and extent to the surrounding structures because of changing the image contrast to surrounding tissues corresponding to the rate of included bound water.

    DOI: 10.6009/jjrt.KJ00003326546

    CiNii Article

    CiNii Books

    researchmap

  • Series(5)"Technical Term Book"Revised Edition

    SUNAYASHIKI TADASHI, Matsuda Tsuyoshi

    Japanese Journal of Radiological Technology   60 ( 10 )   1405 - 1407   2004

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003326540

    CiNii Article

    CiNii Books

    researchmap

  • 可変Flip Angle SPGRによる造影ダイナミックT1値計測MRI

    石森 佳幸, 木村 浩彦, 松田 豪, 植松 秀昌, 石田 智一, 福屋 裕子, 北 章延

    日本放射線技術学会雑誌   59 ( 12 )   1535 - 1541   2003.12

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    造影ダイナミックMRIにおいてリアルタイムにT1値計測が可能な手法を開発し臨床応用を試みた.SPGRシーケンスを改良し,一画像ごとにflip angleを変化することを可能にすることによって,異なるflip angleで得られた画像より静的な状態での組織のT1値を計測することを可能にし,引き続き一定のflip angleのもとで得られた画像の信号強度変化から造影効果によるT1値変化の換算を実現した.臨床例は聴神経腫瘍で,一般に神経鞘腫は血流量はあまり豊富ではなく,血管外への造影剤浸出は多い.又,造影遅延相ではよく似た像を呈する髄膜腫とはダイナミックスタディでは異なる信号変化を呈することがよく知られている.1/T1値ダイナミックカーブでも神経鞘腫の特徴である徐々に造影効果が上がる現象を捉えられている.測定対象に応じた最適なスキャンパラメータを選ぶことにより,10%前後の精度で造影ダイナミックT1値計測MRIが実現できた

    DOI: 10.6009/jjrt.kj00000921684

    researchmap

  • MRシリーズ 高速撮像技術

    松田 豪

    日本放射線技術学会雑誌   59 ( 10 )   1209 - 1217   2003.10

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Spiral scanにおけるshared armの割合が画像に及ぼす影響

    奥秋 知幸, 今井 宜雄, 藤本 慶子, 若松 修, 山本 恵理, 松田 豪

    日本放射線技術学会雑誌   59 ( 9 )   1036 - 1037   2003.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 頭部領域における3TMR装置の撮影パラメータの最適化 1.5Tとの比較

    藤原 康博, 北 章延, 福屋 裕子, 石森 佳幸, 森 光一, 東村 享治, 山田 和弘, 米倉 義晴, 藤林 康久, 松田 豪, 平田 直樹

    日本放射線技術学会雑誌   59 ( 9 )   1068 - 1068   2003.9

  • 代謝物拡散能を利用した細胞内・外コンパートメント環境の疾患と発達による変化の検討

    原田 雅史, 松崎 健司, 宇野 昌明, 森 健治, 松田 豪

    INNERVISION   18 ( 8 )   55 - 55   2003.7

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    MRIのみでは組織や細胞のコンパートメントを分離し評価することは困難であると考えられ,代謝物の局在を利用したコンパートメント評価は有用性が高いと考えられた.代謝物濃度に加えて代謝物ごとの拡散能を測定することにより,代謝物の局在ごとのコンパートメントの環境変化の違いを評価した.臨床用MRI装置による代謝物拡散能の測定は,技術的な改善の余地と,臨床応用のための再現性やばらつきの検討を加える必要があるが,十分実用であり,これ迄の方法では得られない細胞や組織の局在化が可能であり,これらに起因する環境変化を反映する情報が非侵襲的に得られる点で,臨床的にも非常に有用な方法であると考えられた

    researchmap

  • Elliptical centric view orderとk-space中心選択の脂肪抑制法を併用した腹部造影三次元MRA

    天野 康雄, 高浜 克也, 松田 豪, 古川 一博, 天野 真紀, 隈崎 達夫

    日本医学放射線学会雑誌   63 ( 2 )   S207 - S207   2003.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • Radiological Technologists Hope to Increase Activities in the Industries

    高橋 理奈, 仁井田 秀治, 西水 誠治, 松田 豪, 水内 宣夫, 藤田 広志

    日本放射線技術學會雜誌   59 ( 1 )   1 - 20   2003.1

     More details

    Language:Japanese   Publisher:社団法人日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

  • 3T MRI/MRSへの期待

    木村浩彦, 越元佳郎, 角 弘諭, 石森佳幸, 伊藤春海, 椛沢宏之, 松田 豪

    GE today   MR特別号   17 - 18   2003

     More details

  • Study of Elliptical Centric View Ordering Technique with Spectrally Selected Inversion Recovery Pulse (spec-IR pulse)

    OKUAKI TOMOYUKI, YAMASHITA MIDORI, WAKAMATSU OSAMU, SHIROUZU ICHIRO, MACHIDA TORU, MATSUDA TSUYOSHI

    Japanese Journal of Radiological Technology   59 ( 3 )   401 - 409   2003

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    Among several techniques for contrast-enhanced MRA, the elliptical centric view ordering method, originally developed at the Mayo Clinic, is a promising one. It has been difficult to apply a fat-suppression prepulse, mainly because the conventional fat suppression method requires a longer acquisition time during sampling of the lowfrequency domain in k-space, and it causes severe image distortion due to the great change in longitudinal magnetization derived from fat tissue. We developed a novel method to append fat saturation to the elliptical centric view ordering technique, and assessed the feasibility of its use. Our method is to apply fat-saturation pulses only at selected sampling points when any gradient is applied in the slice-encoding direction. In this way, we achieved efficient suppression of fat-derived signal within a relatively short time, comparable to that of the conventional fat-saturation method, and succeeded in minimizing artifacts.

    DOI: 10.6009/jjrt.KJ00000921769

    CiNii Article

    CiNii Books

    researchmap

  • k空間を工夫した撮像方法(<シリーズ>よりよい撮影技術を求めて(その66))

    松田 豪

    放射線撮影分科会誌   40 ( 0 )   65 - 66   2003

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.40.0_65

    CiNii Article

    CiNii Books

    researchmap

  • 181 頭部領域における3TMR装置の撮影パラメータの最適化-1.5Tとの比較-(MR臨床 頭部)

    藤原 康博, 松田 豪, 平田 直樹, 北 章延, 福屋 裕子, 石森 佳幸, 森 光一, 東村 享治, 山田 和弘, 米倉 義晴, 藤林 康久

    日本放射線技術学会雑誌   59 ( 9 )   1068 - 1068   2003

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00000922051

    CiNii Article

    researchmap

  • 43 Spiral scanにおけるshared armの割合が画像に及ぼす影響(MR基礎 パルスシーケンス)

    奥秋 知幸, 今井 宜雄, 藤本 慶子, 若松 修, 山本 恵理, 松田 豪

    日本放射線技術学会雑誌   59 ( 9 )   1036 - 1037   2003

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00000921915

    CiNii Article

    researchmap

  • Dynamic Contrast-enhanced T_1 Measuring MRI Using Variable Flip Angle SPGR

    ISHIMORI YOSHIYUKI, KIMURA HIROHIKO, MATSUDA TSUYOSHI, UEMATSU HIDEMASA, ISHIDA TOMOKAZU, FUKUYA YUKO, KITA AKINOBU

    Japanese Journal of Radiological Technology   59 ( 12 )   1535 - 1541   2003

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    We modified the multi-phase spoiled gradient recalled echo (SPGR.) pulse sequence using the double-echo MR technique for estimation of T_1 during the first pass of contrast agent, and examined its precision. In the first half of the pulse sequence, the flip angle was varied systematically to calculate static T_1 values. It was necessary to choose optimal flip angles to minimize the calculation error of static T_1 values. In the latter half of this sequence, changes in absolute T_1 were calculated using differences in signal intensities before and after the injection of contrast agent. The optimal flip angle was 20 degrees for precise conversion to T_1 values under the short TR(33.3 ms)condition. Double echo MR data were used to minimize the T_2 effect. The present method appears to be useful for quantitative estimation of dynamic contrast-enhanced MRI.

    DOI: 10.6009/jjrt.KJ00000921684

    CiNii Article

    CiNii Books

    researchmap

  • Description of the Fast Scan Method in MRI (<Basic Lectures>MR Series)

    MATSUDA TSUYOSHI

    Japanese Journal of Radiological Technology   59 ( 10 )   1209 - 1217   2003

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    初期の頃のMRの撮影はSE (spin echo)法が中心であり,1枚の画像を得るために数分から,十数分の時間が必要であった.これを改善するためにさまざまな工夫が続けられ,現在に至っている.これには主にパルスシーケンスの工夫と,画像再構成の工夫があり,それらを組み合わせて高速化を行っている.今回は高速撮影がどのような方法で達成されているかまとめることで(Fig. 1)日常業務に役立てていただくことを目的とした.

    DOI: 10.6009/jjrt.KJ00000921628

    CiNii Article

    CiNii Books

    researchmap

  • Radiological Technologists Hope to Increase Activities in the Industries(New Year Round Table Discussion)

    高橋 理奈, 仁井田 秀治, 西水 誠治, 松田 豪, 水内 宣夫, 藤田 広志

    Japanese Journal of Radiological Technology   59 ( 1 )   1 - 20   2003

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00000921584

    CiNii Article

    CiNii Books

    researchmap

  • Spiral scanにおける基礎的検討 コントラスト分解能について

    奥秋 知幸, 今井 宜雄, 下平 貴史, 吉田 仁美, 若松 修, 松田 豪

    日本放射線技術学会雑誌   58 ( 9 )   1156 - 1156   2002.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Spiral scanを用いたMRDSAの検討

    奥秋 知幸, 今井 宜雄, 下平 貴史, 吉田 仁美, 若松 修, 松田 豪

    日本放射線技術学会雑誌   58 ( 9 )   1186 - 1186   2002.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Spiral scanにおける基礎的検討 空間分解能について

    奥秋 知幸, 今井 宜雄, 下平 貴史, 吉田 仁美, 若松 修, 松田 豪

    日本放射線技術学会雑誌   58 ( 9 )   1156 - 1156   2002.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • MR現象 緩和

    松田 豪

    日本放射線技術学会雑誌   58 ( 7 )   895 - 903   2002.7

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 心臓の描出技術と診断能(よりよい撮影技術を求めて(その60) : 心臓)(第38回撮影分科会報告)

    松田 豪

    放射線撮影分科会誌   39 ( 0 )   46 - 47   2002

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.39.0_46

    CiNii Article

    CiNii Books

    researchmap

  • 207 Spiral scanを用いたMRDSAの検討(第30回秋季学術大会 一般研究発表予稿集)

    奥秋 知幸, 今井 宜雄, 下平 貴史, 吉田 仁美, 若松 修, 松田 豪

    日本放射線技術学会雑誌   58 ( 9 )   1186 - 1186   2002

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001364732

    CiNii Article

    researchmap

  • 72 Spiral scanにおける基礎的検討 : 空間分解能について(第30回秋季学術大会 一般研究発表予稿集)

    奥秋 知幸, 今井 宜雄, 下平 貴史, 吉田 仁美, 若松 修, 松田 豪

    日本放射線技術学会雑誌   58 ( 9 )   1156 - 1156   2002

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001364599

    CiNii Article

    researchmap

  • 71 Spiral scanにおける基礎的検討 : コントラスト分解能について(第30回秋季学術大会 一般研究発表予稿集)

    奥秋 知幸, 今井 宜雄, 下平 貴史, 吉田 仁美, 若松 修, 松田 豪

    日本放射線技術学会雑誌   58 ( 9 )   1156 - 1156   2002

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001364598

    CiNii Article

    researchmap

  • Effect of Relaxation Time in Flair Magnetic Resonance Imaging(Clinical Technology Corse)

    MATSUDA TSUYOSHI

    Japanese Journal of Radiological Technology   58 ( 7 )   895 - 903   2002

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001364328

    CiNii Article

    CiNii Books

    researchmap

  • 「心臓の描出技術と診断能」 : よりよい撮影技術を求めて(その60)「心臓」

    松田 豪, 宮崎 茂

    放射線撮影分科会誌   38 ( 0 )   20 - 21   2002

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.38.0_20

    CiNii Article

    CiNii Books

    researchmap

  • MRパラメータの臨床応用への検討

    松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1062 - 1062   2001.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 脂肪抑制パルスを付加したelliptic centric view order法の検討

    奥秋 知幸, 今井 宜雄, 島 孝次, 下平 貴史, 山下 緑, 若松 修, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1066 - 1066   2001.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • elliptic centric法における脂肪抑制(Spec-IR)の基礎的検討

    土橋 俊男, 岩崎 淳, 森 克彦, 鈴木 健, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1065 - 1066   2001.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 脂肪抑制併用elliptical centric view orderingの基礎的検討

    高橋 光幸, 荒田 光俊, 森 直彦, 畑中 千代, 山之口 稔, 高原 太郎, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1065 - 1065   2001.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 3T MRSにおけるグルタミン酸,グルタミンの分離同定

    石森 佳幸, 石田 智一, 東村 享治, 伊藤 春海, 米倉 義晴, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1027 - 1027   2001.9

  • MRI of Ischemic Heart Disease

    MATSUDA TSUYOSHI

    Japanese Journal of Radiological Technology   57 ( 6 )   664 - 670   2001

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001357594

    CiNii Article

    CiNii Books

    researchmap

  • 220 MRパラメータの臨床応用への検討

    松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1062 - 1062   2001

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003111239

    CiNii Article

    researchmap

  • 58 3T MRSにおけるグルタミン酸, グルタミンの分離固定

    石森 佳幸, 石田 智一, 東村 享治, 伊藤 春海, 米倉 義晴, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1027 - 1027   2001

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003111078

    CiNii Article

    researchmap

  • 235 脂肪抑制パルスを付加したelliptic centric view order法の検討

    奥秋 知幸, 今井 宜雄, 島 孝次, 下平 貴史, 山下 緑, 若松 修, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1066 - 1066   2001

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003111254

    CiNii Article

    researchmap

  • 234 elliptic centric法における脂肪抑制(Spec-IR)の基礎的検討

    土橋 俊男, 岩崎 淳, 森 克彦, 鈴木 健, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1065 - 1066   2001

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003111253

    CiNii Article

    researchmap

  • 233 脂肪抑制併用elliptical centric view orderingの基礎的検討

    高橋 光幸, 荒田 光俊, 森 直彦, 畑中 千代, 山之口 稔, 高原 太郎, 松田 豪

    日本放射線技術学会雑誌   57 ( 9 )   1065 - 1065   2001

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003111252

    CiNii Article

    researchmap

  • 3T MRIにおける受信帯域幅と画像特性

    石森 佳幸, 石田 智一, 小室 裕冉, 伊藤 春海, 米倉 義晴, 松田 豪

    日本放射線技術学会雑誌   56 ( 9 )   1121 - 1121   2000.9

  • 送信方法の違いがFAIR画像に与える影響について

    奥秋 知幸, 山下 緑, 若松 修, 松田 豪

    日本放射線技術学会雑誌   56 ( 9 )   1124 - 1124   2000.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Fresher's Seminar MR Inspection Technique for the Beginners-Q&A

    DOI Tsukasa, Matsuda Tsuyoshi

    日本放射線技術學會雜誌   56 ( 8 )   1010 - 1025   2000.8

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001357037

    CiNii Article

    CiNii Books

    researchmap

  • 3T MRIにおける磁場均一性の影響

    石森 佳幸, 石田 智一, 小室 裕冉, 伊藤 春海, 米倉 義晴, 定藤 規弘, 岡田 知久, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   56回 ( 56 )   36 - 36   2000.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2003156258

  • saturation recovery SSFSE法を用いた造影検査への応用に対する検討

    石田 智一, 石森 佳幸, 竹内 美穂, 指江 浩之, 小室 裕冉, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   56回 ( 56 )   255 - 255   2000.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2003156477

  • 超高磁場MR装置を用いたプロトンスペクトロスコピーに関する基礎研究

    大久保 真樹, 中田 力, 松沢 等, 松田 豪

    INNERVISION   15 ( 8 )   66 - 66   2000.7

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    prototypeの3T-MR装置を用いて,ヒト脳における1H-MRSを測定することができた.磁場強度上昇に伴うS/Nの上昇により測定時間が短縮され,再現性の良いGlxピークを検出することが可能であった

    researchmap

  • 代謝物拡散能の臨床症例における検討

    原田 雅史, 久岡 園花, 米田 和英, 西谷 弘, 松田 豪

    日本医学放射線学会雑誌   60 ( 6 )   330 - 330   2000.5

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • 脳梗塞超急性期における治療法選択のためのMRI診断基準の検討 MRIによる脳環流画像とエネルギー代謝画像の開発と応用

    原田 雅史, 米田 和英, 久岡 園花, 岡田 稔子, 西谷 弘, 宇野 昌明, 新野 清人, 永廣 信治, 松田 豪

    四国医学雑誌   56 ( 2 )   83 - 84   2000.4

     More details

    Language:Japanese   Publisher:徳島医学会  

    researchmap

  • Improvement of Chemical Shift Selective Saturation (CHESS) Pulse for MR Angiography

    Ishimori Yoshiyuki, Hiraga Akira, Matsuda Tsuyoshi, Sashie Hiroyuki

    Japanese Journal of Radiological Technology   56 ( 7 )   929 - 936   2000

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    We improved the fat suppression technique based on chemical shift selective saturation (CHESS). To do this, we shortened the duration of the CHESS pulse to achieve a short repetition time (TR) for MR angiography (MRA). A short-duration CHESS pulse causes broad frequency band saturation, creating extensive offset from the resonance frequency of water. In our phantom experiment, the best parameters of the short-duration CHESS pulse were 3.84 ms in duration, -650 Hz in offset frequency from water resonance, and had a 130-degree flip angle. With this technique, MRA will be able to be carried out without a significant increase in TR. Thus, better vessel contrast will be maintained in time-of-flight (TOF) MRA or contrast-enhanced MRA when using the maximum intensity projection (MIP) method.

    DOI: 10.6009/jjrt.KJ00001357001

    CiNii Article

    CiNii Books

    researchmap

  • MR信号強度向上のための技術

    松田 豪

    放射線撮影分科会誌   34 ( 0 )   50 - 51   2000

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.34.0_50

    CiNii Article

    CiNii Books

    researchmap

  • 130 送信方法の違いがFAIR画像に与える影響について

    奥秋 知幸, 山下 緑, 若松 修, 松田 豪

    日本放射線技術学会雑誌   56 ( 9 )   1124 - 1124   2000

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001357200

    CiNii Article

    researchmap

  • 119 3T MRIにおける受信帯域幅と画像特性

    石森 佳幸, 石田 智一, 小室 裕冉, 伊藤 春海, 米倉 義晴, 松田 豪

    日本放射線技術学会雑誌   56 ( 9 )   1121 - 1121   2000

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001357189

    CiNii Article

    researchmap

  • Q1 「MRの信号はどのようにして得られるのですか?」「また, 画像コントラストが得られるメカニズムは?」

    松田 豪

    日本放射線技術学会雑誌   56 ( 8 )   1011 - 1013   2000

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001357038

    CiNii Article

    researchmap

  • MRIとの比較対象試験によるproton MRS(PROBE)の有用性と問題点について 徳島大学での検討

    原田 雅史, 大塚 秀樹, 西谷 弘, 永澤 清, 高橋 良行, 松田 豪

    INNERVISION   14 ( 11 )   104 - 106   1999.10

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    researchmap

  • 【脳のイメージングupdate 解剖から治療まで】 血管病変 虚血性脳血管障害の脳血流イメージング FAIR法を中心に

    白水 一郎, 町田 徹, 野田 正信, 山上 哲央, 土居 逸平, 佐藤 博司, 松田 豪, 高橋 良行

    臨床放射線   44 ( 11 )   1361 - 1368   1999.10

     More details

    Language:Japanese   Publisher:金原出版(株)  

    researchmap

  • 脳灌流画像におけるmulti slice FAIR法の基礎的検討

    高羽 順子, 澤本 恵美, 大石 康子, 中島 健雄, 玖島 利男, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   863 - 863   1999.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • FAIRを用い跡脳血流再構成画像の試み

    奥秋 知幸, 今井 宜雄, 渡邊 誠, 濱野 浩二, 山下 緑, 若松 修, 佐藤 博司, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   863 - 863   1999.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Spec-IR脂肪抑制を用いた2D MRDSA

    石森 佳幸, 石田 智一, 竹内 美穂, 指江 浩之, 木戸屋 栄次, 小室 裕冉, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   861 - 861   1999.9

  • 高分解能造影MRA(ec3d)の試み 頭頸部領域を中心に

    奥秋 知幸, 今井 宜雄, 渡邊 誠, 濱野 浩二, 山下 緑, 若松 修, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   910 - 910   1999.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Proton MR Spectroscopyによる脳の領域別代謝物質の定量(第2報)

    原田 邦明, 板東 道夫, 小田原 好宏, 鎌形 政樹, 才川 恒彦, 白勢 竜二, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   55回 ( 55 )   432 - 432   1999.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2000048607

  • FAIRにおけるMPGパルス付加の有用性

    今井 宜雄, 奥秋 知幸, 山下 緑, 渡邊 誠, 小林 正敏, 佐藤 博司, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   55回 ( 55 )   421 - 421   1999.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2000067600

  • 頭部領域における3D-MRAの検討

    平野 透, 才川 恒彦, 板東 道夫, 白勢 竜二, 原田 邦明, 小寺 秀一, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   55回 ( 55 )   123 - 123   1999.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2000054545

  • Broad Band CHESS Pulseによる3D TOF MRAの検討

    平賀 顯, 小泉 幸司, 伊藤 裕之, 野原 弘基, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   55回 ( 55 )   53 - 53   1999.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2000054538

  • Multi angle MRDSAの試み

    石森 佳幸, 指江 浩之, 竹内 美穂, 石田 智一, 小室 裕冉, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   55回 ( 55 )   51 - 51   1999.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2000054536

  • プロトン化学シフト映像法の臨床応用

    吉川 宏起, 井上 優介, 淺井 佐江, 星野 仁彦, 岩本 愛吉, 松田 豪

    日本医学放射線学会雑誌   59 ( 2 )   S172 - S172   1999.2

     More details

    Language:Japanese   Publisher:(公社)日本医学放射線学会  

    researchmap

  • Q/AMRに関して

    松田 豪

    放射線撮影分科会誌   32 ( 0 )   84 - 85   1999

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.18973/photographingjsrt.32.0_84

    CiNii Article

    CiNii Books

    researchmap

  • 230 高分解能造影MRA (ec3d)の試み : 頭頸部領域を中心に

    奥秋 知幸, 今井 宜雄, 渡邊 誠, 濱野 浩二, 山下 緑, 若松 修, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   910 - 910   1999

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003110838

    CiNii Article

    researchmap

  • 93 SSFSEによるT_1強調像に対する撮像条件の最適化

    石田 智一, 石森 佳幸, 竹内 美穂, 指江 浩之, 木戸屋 栄治, 小室 裕冉, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   864 - 864   1999

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    CiNii Article

    researchmap

  • 90 脳灌流画像におけるmulti slice FAIR法の基礎的検討

    高羽 順子, 澤本 恵美, 大石 康子, 中島 健雄, 玖島 利男, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   863 - 863   1999

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003110698

    CiNii Article

    researchmap

  • SSFSEによるT1強調像に対する撮像条件の最適化

    石田 智一, 石森 佳幸, 竹内 美穂, 指江 浩之, 木戸屋 栄治, 小室 裕冉, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   864 - 864   1999

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003110701

    CiNii Article

    researchmap

  • 89 FAIRを用いた脳血流再構成画像の試み

    奥秋 知幸, 今井 宜雄, 渡邊 誠, 濱野 浩二, 山下 緑, 若松 修, 佐藤 博司, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   863 - 863   1999

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003110697

    CiNii Article

    researchmap

  • 84 Spec-IR脂肪抑制を用いた2D MRDSA

    石森 佳幸, 石田 智一, 竹内 美穂, 指江 浩之, 木戸屋 栄次, 小室 裕冉, 松田 豪

    日本放射線技術学会雑誌   55 ( 9 )   861 - 861   1999

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003110692

    CiNii Article

    researchmap

  • Lactate editing proton MR spectroscopy

    大屋 成之, 青木 純, 遠藤 啓吾, 松田 豪

    INNERVISION   13 ( 11 )   121 - 122   1998.9

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    researchmap

  • テーブル移動型efgre3dの有用性

    指江 浩之, 石森 佳幸, 石田 智一, 竹内 美穂, 福島 哲弥, 小室 裕冉, 松田 豪

    日本放射線技術学会雑誌   54 ( 9 )   1110 - 1110   1998.9

  • short duration CHESS pulseによる3DTOF MRAの画質改善

    石森 佳幸, 指江 浩之, 竹内 美穂, 石田 智一, 小室 裕冉, 松田 豪

    日本放射線技術学会雑誌   54 ( 9 )   1108 - 1108   1998.9

  • Proton spectroscopyの標準化(Probe/SV)について

    松田 豪

    INNERVISION   13 ( 11 )   125 - 126   1998.9

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    researchmap

  • AIDS患者における1H-MRSの有用性

    星野 仁彦, 岩本 愛吉, 吉川 宏起, 井上 優介, 松田 豪

    INNERVISION   13 ( 11 )   123 - 124   1998.9

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    decreased groupは最終的に全例,中枢神経系日和見疾患が存在した.また,decreased groupは有意に髄液中HIV-RNAが高値であった.更に,decreased groupは6名中5名が死亡し,病理解剖の結果,中枢神経系日和見疾患が証明されている.non-decreased groupでは10名中2名が死亡したが,その2名とも死因は中枢神経疾患とは無関係であった

    researchmap

  • proton MRSによる脳の領域別の代謝物質の定量

    原田 邦明, 板東 道夫, 才川 恒彦, 小田原 好宏, 鎌形 政樹, 白勢 竜二, 松田 豪

    日本放射線技術学会雑誌   54 ( 9 )   1102 - 1102   1998.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 【Step up MRI '98】 新しい撮像法の現状と臨床応用 頭部 Non-contrast MR perfusionの動向 FAIR法を中心に,定量化への鍵

    木村 浩彦, 越元 佳郎, 植松 秀昌, 山田 弘樹, 前田 正幸, 河村 泰孝, 石井 靖, 佐藤 博司, 松田 豪

    INNERVISION   13 ( 10 )   10 - 12   1998.8

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    researchmap

  • SSFSEの画像コントラストと諸因子

    石森 佳幸, 指江 浩之, 石田 智一, 小室 裕冉, 松田 豪

    日本放射線技術学会総会学術大会一般研究発表後抄録   54回 ( 54 )   127 - 127   1998.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/1999239410

  • MR装置による機能の描出 形態から機能へ MRSによる機能の表現

    松田 豪

    日本放射線技術学会雑誌   54 ( 5 )   680 - 683   1998.5

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Correction of image intensity in case of using surface coil

    Ishimori Yoshiyuki, Sashie Hiroyuki, Komuro Hiroyuki, Matsuda Tsuyoshi

    Japanese Journal of Radiological Technology   54 ( 1 )   61 - 61   1998

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001351731

    CiNii Article

    CiNii Books

    researchmap

  • 3.Function:Evaluation with Magnetic Resonance Spectroscopy(Technical Study on Visualization of Human Body Function by MR:From Morphology to Physiology)

    MATSUDA TSUYOSHI

    Japanese Journal of Radiological Technology   54 ( 5 )   680 - 683   1998

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003110008

    CiNii Article

    CiNii Books

    researchmap

  • Usefulness of Enhanced 3D Fast Gradient Echo Sequence with Moving Bed System

    指江 浩之, 石森 佳幸, 石田 智一, 竹内 美穂, 福島 哲弥, 小室 裕冉, 松田 豪

    Japanese Journal of Radiological Technology   54 ( 9 )   1110 - 1110   1998

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001352233

    CiNii Article

    researchmap

  • 3D TOF MRA with Short Duration Chemical Shift Selective Pulse

    石森 佳幸, 指江 浩之, 竹内 美穂, 石田 智一, 小室 裕冉, 松田 豪

    Japanese Journal of Radiological Technology   54 ( 9 )   1108 - 1108   1998

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001352229

    CiNii Article

    researchmap

  • Quantitation of Brain Metabolites Using Proton MR Spectroscopy

    原田 邦明, 板東 道夫, 才川 恒彦, 小田原 好宏, 鎌形 政樹, 白勢 竜二, 松田 豪

    Japanese Journal of Radiological Technology   54 ( 9 )   1102 - 1102   1998

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001352211

    CiNii Article

    researchmap

  • 結節性硬化症における皮質結節のFLAIR法による評価

    前田 正幸, 松田 豪, 土田 千賀, 越元 佳郎, 植松 秀昌, 山田 弘樹, 木村 浩彦, 河村 康孝, 石井 靖

    日本磁気共鳴医学会雑誌   17 ( Suppl. )   272 - 272   1997.9

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    researchmap

  • Gd-DTPA(ジエンチレントリアミン5酢酸)ボーラス通過中脳腫瘍におけるT1効果の研究

    植松 秀昌, 前田 正幸, 松田 豪, 木村 浩彦, 山田 弘樹, 河村 泰孝, 指江 浩之, 石森 佳幸, 越元 佳郎, 土田 千賀

    日本磁気共鳴医学会雑誌   17 ( Suppl. )   132 - 132   1997.9

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    researchmap

  • Inversion Recovery-Echo Planar Imagingを用いた定量的MR Perfusion計測の試み

    木村 浩彦, 越元 佳郎, 土田 千賀, 植松 秀昌, 山田 弘樹, 前田 正幸, 河村 泰孝, 石井 靖, 佐藤 博司, 松田 豪

    日本磁気共鳴医学会雑誌   17 ( Suppl. )   155 - 155   1997.9

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    researchmap

  • EPIを用いたIVIM法

    松田 豪

    日本放射線技術学会雑誌   53 ( 8 )   1327 - 1327   1997.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 腹部領域におけるMRの特徴を生かした撮像法

    松田 豪

    日本放射線技術学会雑誌   53 ( 6 )   743 - 745   1997.6

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • EPIを用いたT1値計測

    松田 豪

    日本放射線技術学会雑誌   53 ( 1 )   48 - 48   1997.1

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 458 Intravoxel incoherent motion (IVIM)imaging using epi method

    Matsuda Tsuyoshi, Sashie Hiroyuki, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   53 ( 8 )   1327 - 1327   1997

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001356299

    CiNii Article

    CiNii Books

    researchmap

  • Correction of Image Intensity in Case of Using Surface Coil

    石森 佳幸, 指江 浩之, 小室 裕冉, 松田 豪

    Japanese Journal of Radiological Technology   53 ( 9 )   1419 - 1419   1997

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001356403

    CiNii Article

    researchmap

  • Measurement of T1 value using EPI sequence.

    Matsuda tsuyoshi, Sashie hiroyuki, Komuro hiroyuki

    Japanese Journal of Radiological Technology   53 ( 1 )   48 - 48   1997

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001355043

    CiNii Article

    CiNii Books

    researchmap

  • Improvement of the Automatic Injector for MRI

    Sashie Hiroyuki, Matsuda Tsuyoshi, Komuro Hiroyuki, Kawamura Yasutaka, Tano Atsuhisa

    Japanese Journal of Radiological Technology   53 ( 7 )   955 - 955   1997

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001355972

    CiNii Article

    CiNii Books

    researchmap

  • 4.Scan Technique Using MR in Abdomial Region(Workshop : Im pursuit of battery Scan techniques(31)"Characteristics of CT and MR in the Thoraco-abdminkl Region")

    MATSUDA TSUYOSHI

    Japanese Journal of Radiological Technology   53 ( 6 )   743 - 745   1997

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001355793

    CiNii Article

    CiNii Books

    researchmap

  • Evaluation of fast-FLAIR using EPI in MRI of the brain

    Sashie Hiroyuki, Matsuda Tsuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   53 ( 1 )   177 - 177   1997

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001355172

    CiNii Article

    CiNii Books

    researchmap

  • 領域選択proton MRSの小VOI化(第2報)

    松田 豪

    日本放射線技術学会雑誌   52 ( 10 )   1356 - 1356   1996.10

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • EPIを用いたT1値計測

    松田 豪

    日本放射線技術学会雑誌   52 ( 8 )   900 - 900   1996.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Small VOI proton NMR spectroscopy. (The 2nd report)

    Matsuda Tsuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   52 ( 10 )   1356 - 1356   1996

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001353817

    CiNii Article

    CiNii Books

    researchmap

  • Evaluation of fast-FLAIR using EPI in MRI of the brain

    指江 浩之, 松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   52 ( 8 )   943 - 943   1996

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001354684

    CiNii Article

    researchmap

  • Measurement of T1 value using EPI sequence.

    松田 豪, 指江 浩之, 小室 裕冉

    Japanese Journal of Radiological Technology   52 ( 8 )   900 - 900   1996

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001354554

    CiNii Article

    researchmap

  • MR コイル(座長集約)

    松田 豪

    日本放射線技術学会雑誌   52 ( 2 )   300 - 300   1996

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001354236

    CiNii Article

    researchmap

  • 前立腺疾患のスペクトロスコピー

    友井 正弘, 吉田 正徳, 松田 豪

    臨床画像   11 ( 増刊 )   181 - 187   1995.10

     More details

    Language:Japanese   Publisher:(株)メジカルビュー社  

    researchmap

  • 領域選択Proton MRSの小VOI化

    松田 豪

    日本放射線技術学会雑誌   51 ( 8 )   988 - 988   1995.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 臨床用MR装置(1channel送信機)を用いてのMTC定量測定の試み

    松田 豪

    日本放射線技術学会雑誌   51 ( 8 )   1093 - 1093   1995.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • The Analysis of Bone Trabecules by Gradient-echo Technique

    IWASAKI Toshiko, Matsuda Tsuyoshi, TUKAHARA Kouichi, TAMAGAWA Youichi, KIMURA Hirohiko, ITOU Satoshi, MAEDA Masayuki, HAYASHI Nobushige, YAMAMOTO Kazutaka, ISHII Yasushi

    日本磁気共鳴医学会雑誌   15 ( 5 )   145 - 152   1995.7

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    Gradient echo法において認められる信号低下率1/T2*を利用して,非侵襲的な局所骨梁評価の試みを行った.ファントム実験では信号低下率1/T2*は磁化率の異なる物質間の界面積密度に相関することが明らかとなった.臨床応用では成長による骨塩量の増加に1/T2*が相関するが,骨塩量増加と共に1/T2*増加の程度は緩やかとなり,単なる骨塩量の変化に加えて骨梁の構成内容の変化も加味されることが示唆された.従って本法は骨梁変化の評価に有用であろうと考えた

    CiNii Article

    CiNii Books

    researchmap

  • 生体T1値測定の検討

    松田 豪

    日本放射線技術学会雑誌   51 ( 3 )   231 - 231   1995.3

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 7.MTCの基礎的検討(中部部会)

    松田 豪, 小室 裕冉, 土田 千賀, 岩崎 俊子, 石井 靖

    日本放射線技術学会雑誌   51 ( 6 )   767 - 767   1995

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003109334

    CiNii Article

    researchmap

  • MR : MTC

    松田 豪

    日本放射線技術学会雑誌   51 ( 3 )   373 - 374   1995

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001353608

    CiNii Article

    researchmap

  • Evaluation of in vivo T1 measuremet

    Matsuda Tuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   51 ( 3 )   231 - 231   1995

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001353449

    CiNii Article

    CiNii Books

    researchmap

  • MR 乳房・コイル

    松田 豪, 篠原, 小林

    日本放射線技術学会雑誌   51 ( 10 )   1589 - 1590   1995

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001353310

    CiNii Article

    researchmap

  • Quantitative evaluation of MTC using 1channel irradiation MR machine.

    Matsuda Tsuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   51 ( 8 )   1093 - 1093   1995

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001352668

    CiNii Article

    CiNii Books

    researchmap

  • Small VOI proton NMR spectroscopy.

    Matsuda Tsuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   51 ( 8 )   988 - 988   1995

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001352563

    CiNii Article

    CiNii Books

    researchmap

  • Evaluation of the Registration technique in time course MR images

    ISHIDA TOMOKAZU, TANAKA MASATO, MATUDA TSUYOSHI, KOMURO HIROYUKI

    Japanese Journal of Radiological Technology   51 ( 8 )   948 - 948   1995

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00001352523

    CiNii Article

    CiNii Books

    researchmap

  • Proton spectroscopyにおけるSpatial SATの有用性(第2報)

    松田 豪

    日本放射線技術学会雑誌   50 ( 8 )   1391 - 1391   1994.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 脳におけるFluid attenuated inversion recoveryの基礎的検討

    松田 豪

    日本放射線技術学会雑誌   50 ( 2 )   274 - 274   1994.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 1H-MRS,拡散強調像,T2及び造影T1強調像を用いた実験的急性期脳梗塞の検討

    伊藤 哲, 前田 正幸, 松田 豪

    日本磁気共鳴医学会雑誌   14 ( 1 )   67 - 77   1994.1

     More details

    Language:Japanese   Publisher:(一社)日本磁気共鳴医学会  

    1)成猫に実験的に脳梗塞巣を作成し,拡散強調後,T2及び造影T1強調像によって捉えられた細胞内浮腫から細胞外浮腫への生理学的な変化を,1H-MRSによって追跡することで,生化学的変化との相応についての検討をした。2)拡散強調像では,発症後1時間から細胞内浮腫の状態が拡散係数の低下として示されたが,以後拡散係数は24時間後まで明らかな変化は認められなかった。3)造影T1及びT2強調像においては,BBB破綻にともなう細胞外浮腫の状況が,4時間後より捉え得るようになった。4)1H-MRSにおいては,発症後1時間において嫌気的解糖系の亢進を示す乳酸が認められた。乳酸は24時間後にいたるまで局所に蓄積される傾向にあった。5)生存神経細胞の指標であるNAAは,虚血作成後2時間から3時間後で減少し,以後24時間後に至るまでこの所見は持続した。6)CHOについては水信号の増加によると思われる所見が得られた

    researchmap

  • 301. Functional MRI of The Brain using The Signal Processing Method

    Tanaka Masato, Yamada Hiroki, Matsuda Tsuyoshi, Komuro Hiroyuki, Inoue Hiroshi, Hayashi Kouji

    Japanese Journal of Radiological Technology   50 ( 8 )   1217 - 1217   1994

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    各ピクセルにおける信号解析の結果、運動野領域外でも位相は異なるが運動負荷波形と同じ周波数ピークを示す信号が検出され、その原因として脳機能およびアーチファクトの可能性を検討する必要がある。Hajnalらの研究では指運動負荷による脳全体のモーションアーチファクトの存在を示しその補正の重要性が報告されている(2、3)。一方、信号解析手法の応用による脳賦活画像では、特に周波数処理において位相情報を積極的に用いることで高精度の賦活領域の検出が可能であった。

    DOI: 10.6009/jjrt.KJ00003326101

    CiNii Article

    researchmap

  • 155. Fluid attenuated inversion recovery method in MRI of the brain

    松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   50 ( 2 )   274 - 274   1994

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003534637

    CiNii Article

    researchmap

  • MR 脂肪抑制画像 (演題番号 72〜75)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   50 ( 8 )   1496 - 1497   1994

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003326387

    CiNii Article

    researchmap

  • 476. Usefulness of the Spatial_Saturation Method on Proton spectroscopy (The 2nd report)

    Matsuda Tsuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   50 ( 8 )   1391 - 1391   1994

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003326275

    CiNii Article

    researchmap

  • 15. Evaluation of in vivo T1 measurement

    松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   50 ( 10 )   1762 - 1762   1994

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003325511

    CiNii Article

    researchmap

  • Proton spectroscopyにおけるSpatial-SATの有用性

    松田 豪

    日本放射線技術学会雑誌   49 ( 8 )   1437 - 1437   1993.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 脳のT2*強調ダイナミックMRIの有用性

    松田 豪

    日本放射線技術学会雑誌   49 ( 2 )   323 - 323   1993.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 416. Usefulness of the Spatial_Satulation Method on Proton spectroscopy

    Matsuda Tsuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   49 ( 8 )   1437 - 1437   1993

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003325000

    CiNii Article

    researchmap

  • MR-15 MTC (演題番号 485〜488)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   49 ( 8 )   1590 - 1590   1993

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003325200

    CiNii Article

    researchmap

  • 501. Report from Study groop for the Technique of MRI

    Tamura Sakio, Akai Yoshinori, Izawa Akira, Kawai Hideo, Kumagai Hiroshi, Sukekawa Kazuya, Matsuda Tuyoshi, Seo Takehiko, Yamada Yukinori

    Japanese Journal of Radiological Technology   49 ( 8 )   1522 - 1522   1993

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003325085

    CiNii Article

    researchmap

  • 155. Fluid attenuated inversion recovery method in MRI of the brain

    松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   49 ( 9 )   1669 - 1669   1993

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003325372

    CiNii Article

    researchmap

  • MRI に関する技術的検討班報告

    田村 鋒男, 赤井 喜徳, 井澤 章, 川合 英夫, 助川 和也, 松田 豪, 熊谷 博司, 千尾 武彦, 山田 幸典

    日本放射線技術学会雑誌   49 ( 7 )   962 - 971   1993

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    本班は2年間にわたって事業を継続し以下の問題について検討し結論を得た.1)撮影条件の最適化について1)MRIのスキャン・パラメータは多数あり, アンケートの結果によればそれらはかなり広範囲に分布している.スキャンタイムの短縮, スキャン方向の減少等がスループットに大きく寄与するので各施設の経営方針がバラツキを左右するものと考えられる.2)MRI装置の発展はまだ日進月歩の段階であり各メーカーが開発を競っており用語の統一もまだなされていない.3)MRIは従来のX線写真の評価で問題となるコントラスト, 鮮鋭度以外にT1, T2強調, フロー等の診断要素が加わるので画像診断医の意見も無視できない.4)症例, 撮影部位により撮影パラメータ, コイル, 付属品などハードも異なりこれらを決定することは不可能である.5)MRI装置, 磁場強度によりSN比, コントラスト比が異なるため各装置, 磁場強度ごとに撮影パラメータを設定しなければならず問題が多い.これら以外にも細かな問題点もあり撮影条件の最適化を決定することは困難である.2)性能評価について現状では標準ファントム, SN比, コントラスト比等の測定方法がNEMA, AAPM, EEC等で検討され一部は報告されているが以下の項目について検討した.1)SE法によるT1, T2強調の頭部イメージについてT1強調像の視覚評価では0.5Tの上下で差があった.1.5TではT1強調像の画質がT2強調像より撮影パラメータに影響される傾向にあった.SN比は磁場強度, TR, TEにより異なるが1.5Tの機種間で大きな差があった.コントラスト比は0.3Tで最大となり, TR, TEについては値がバラツイた.原因は画像再構成, パラメータの選択, 動き, フロー等が考えられる.2)班試作の統一ファントム・イメージについて磁場強度によるSN比の差はあった.しかし同一磁場(1.5T)装置間で大きな差がみられた.これはRFコイルの形状, タイプによる感度差, 生データでなく画像表示方法の相違などが主原因と考えられる.TR, TEによるSN比の変動はファントム溶液の緩和時間に依存したものであり装置間で同様な傾向であった.以上の検討よりパラメータの非統一化, ハードの差などによる臨床評価との差はあるが規定したTR, TEによるSN比を用いた性能評価は可能である.

    DOI: 10.6009/jjrt.KJ00003577873

    CiNii Article

    researchmap

  • 501. Report from Study groop for the Technique of MRI

    田村 鋒男, 赤井 嘉徳, 井澤 章, 川合 英夫, 助川 和也, 松田 豪, 熊谷 博司, 千尾 武彦, 山田 幸典

    Japanese Journal of Radiological Technology   49 ( 3 )   543 - 543   1993

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003577738

    CiNii Article

    researchmap

  • 416. Usefulness of the Spatial_Saturation Method on Proton spectroscopy

    松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   49 ( 3 )   526 - 526   1993

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003577652

    CiNii Article

    researchmap

  • MR-2 臨床応用 (演題番号 188〜191)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   49 ( 2 )   350 - 350   1993

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003501294

    CiNii Article

    researchmap

  • 203. Usefulness of dynamic contrast enhanced T2* weighted MRI

    Matsuda Tsuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   49 ( 2 )   323 - 323   1993

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003501248

    CiNii Article

    researchmap

  • Column-IVIM法による局所ADC算出の試み 測定シーケンスの検討

    松田 豪

    日本放射線技術学会雑誌   48 ( 8 )   1529 - 1529   1992.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 165. Localized Proton NMR Spectroscopy useing conventional whole-body MRI system-optimal adjustment of STEAM sequens

    MATSUDA TUYOSHI, KIMURA HIROHIKO, KOMURO HIROYUKI

    Japanese Journal of Radiological Technology   48 ( 2 )   289 - 289   1992

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003533349

    CiNii Article

    researchmap

  • 203. Usefulness of dynamic contrast enhanced T2* weighted MRI

    松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   48 ( 9 )   1761 - 1761   1992

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003577070

    CiNii Article

    researchmap

  • 49. STEAM 法を用いた領域選択 proton MRS の技術的な検討(MRI, 中部部会)

    松田 豪, 木村 浩彦, 伊藤 哲, 小室 裕冉

    日本放射線技術学会雑誌   48 ( 5 )   825 - 825   1992

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003576665

    CiNii Article

    researchmap

  • 446. Assessment of local ADC using colummner-IVIM method : Useful sequence for local ADC mesurement

    松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   48 ( 3 )   565 - 565   1992

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003533976

    CiNii Article

    researchmap

  • MR-2 造影剤 (演題番号 59〜64)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   48 ( 2 )   338 - 339   1992

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003533404

    CiNii Article

    researchmap

  • 165. Localized Proton NMR Spectroscopy useing conventional whole-body MRI system-optimal adjustment of STEAM sequens

    MATSUDA TUYOSHI, KIMURA HIROHIKO, KOMURO HIROYUKI

    Japanese Journal of Radiological Technology   48 ( 2 )   1992

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    CiNii Article

    researchmap

  • MR-2 C.S.I (演題番号 143〜146)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   48 ( 8 )   1629 - 1630   1992

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003500953

    CiNii Article

    researchmap

  • 446. Assessment of local ADC using colummner-IVIM method : Useful sequence for local ADC mesurement

    MATSUDA TUYOSHI, KOMURO HIROYUKI

    Japanese Journal of Radiological Technology   48 ( 8 )   1529 - 1529   1992

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    今回用いたような領域選択によるdata収集法はT1, T2値等、他の計測などにも応用できるため、今後本法を応用したNMRによる正確な定量・定性解析が臨床利用される事を望む。

    DOI: 10.6009/jjrt.KJ00003500842

    CiNii Article

    researchmap

  • 小動物用横型スペクトロメータの利用について 動物実験を対象としたMRS

    松田 豪

    日本放射線技術学会雑誌   47 ( 10 )   1808 - 1813   1991.10

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 臨床用MRI装置による領域選択Proton NMR Spectroscopy Stimulated Echo法の収集条件について

    松田 豪

    日本放射線技術学会雑誌   47 ( 8 )   1111 - 1111   1991.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 画像診断における腫瘍動態とその代謝について

    石井 靖, 木村 浩彦, 松田 豪

    病態生理   10 ( 8 )   655 - 658   1991.8

     More details

    Language:Japanese   Publisher:(株)永井書店  

    researchmap

  • Gradient Echo法を用いたFat Fractionの算出

    松田 豪

    日本放射線技術学会雑誌   47 ( 2 )   130 - 130   1991.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 1. USEAGE OF IN VIVO MR SPECTROMETER FOR SMALL ANIMALS

    MATSUDA TSUYOSHI

    Japanese Journal of Radiological Technology   47 ( 10 )   1808 - 1813   1991

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    Before the clinical application of in vivo MR spectroscopy we performed basic study to obtain better spectrum by using MR spectrometer exclusively designed for animal experiment. In in vivo animal experiment, we could obtained functional or metabolic in vitro information by high spatial resolution non-invasively and non-denstructively. In basic study, we evaluated various probes and radio frequency pulse sequence, and concluded the selection of the most suitable combination of probe and pulse sequence is important acording to reserchers object.

    DOI: 10.6009/jjrt.KJ00003532581

    CiNii Article

    researchmap

  • 76. Localized Proton NMR Spectroscopy useing conventional whole-body MRI system-data acquisition protocoles on Stimulated Echoes Method

    MATSUDA TUYOSHI, KIMURA HIROHIKO, IKENO TOORU, KOMURO HIROYUKI

    Japanese Journal of Radiological Technology   47 ( 8 )   1111 - 1111   1991

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003323820

    CiNii Article

    researchmap

  • 76. Localized Proton NMR Spectroscopy useing conventional whole-body MRI system : data acquisition protocoles on Stimulated Echoes Method

    松田 豪, 木村 浩彦, 池野 徹, 小室 裕冉

    Japanese Journal of Radiological Technology   47 ( 3 )   459 - 459   1991

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003323161

    CiNii Article

    researchmap

  • MR-4 応用技術 (演題番号 155〜158)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   47 ( 2 )   336 - 336   1991

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003323022

    CiNii Article

    researchmap

  • 165. Localized Proton NMR Spectroscopy useing conventional whole-body MRI system : optimal adjustment of STEAM sequens

    松田 豪

    Japanese Journal of Radiological Technology   47 ( 9 )   1757 - 1757   1991

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003532952

    CiNii Article

    researchmap

  • 56. Cardiac wall motion analisis using presaturation tagging techique

    Kidoya Eiji, Matuda Tuyoshi, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   47 ( 2 )   167 - 167   1991

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003322842

    CiNii Article

    researchmap

  • 19. Quantitative Evaluation of Fat Fraction Using Gradient Echo Method

    Matsuda Tsuyoshi, Ikeno Tooru, Komuro Hiroyuki

    Japanese Journal of Radiological Technology   47 ( 2 )   130 - 130   1991

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003322805

    CiNii Article

    researchmap

  • MR-1 MRS-1 P (演題番号 71〜74)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   47 ( 8 )   1582 - 1583   1991

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003324296

    CiNii Article

    researchmap

  • 165. Localized Proton NMR Spectroscopy useing conventional whole-body MRI system : optimal adjustment of STEAM sequens

    松田 豪, 木村 浩彦, 小室 裕冉

    Japanese Journal of Radiological Technology   47 ( 9 )   1991

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    CiNii Article

    researchmap

  • 座長集約(MRI・X 線 CT-I, 中部部会)

    松田 豪

    日本放射線技術学会雑誌   47 ( 10 )   1878 - 1879   1991

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003532724

    CiNii Article

    researchmap

  • Gradient Echo法を用いたFat Fractionの算出

    松田 豪

    日本放射線技術学会雑誌   46 ( 10 )   1636 - 1636   1990.10

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • MRSの現状と技術的課題 小動物用横型スペクトロメーターの利用について 実験動物を対象としたMRS

    松田 豪

    日本放射線技術学会雑誌   46 ( 10 )   1629 - 1629   1990.10

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003499827

    CiNii Article

    researchmap

  • Fast Scan法を用いた顎関節MRI検査の有用性

    松田 豪

    日本放射線技術学会雑誌   46 ( 8 )   1388 - 1388   1990.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • Fast Scan法を用いた顎関節MRI検査の有用性

    松田 豪

    日本放射線技術学会雑誌   46 ( 3 )   592 - 592   1990.3

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • MRIにおけるslow flow detectionの基礎的検討

    松田 豪

    日本放射線技術学会雑誌   46 ( 2 )   119 - 119   1990.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 19. Quantitative Evaluation of Fat Fraction Using Gradient Echo Method

    松田 豪, 池野 徹, 小室 裕冉

    Japanese Journal of Radiological Technology   46 ( 10 )   1636 - 1636   1990

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003499848

    CiNii Article

    researchmap

  • 417. Usefulness of fast-scan method in Temporomandibular joint MR study

    松田 豪, 杉本 勝也, 小室 裕冉, 伊藤 俊祐

    Japanese Journal of Radiological Technology   46 ( 3 )   592 - 592   1990

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003576387

    CiNii Article

    researchmap

  • 30. QDR-1000 の性能評価(CT・骨塩定量, 中部部会)

    上坂 秀樹, 池野 徹, 石森 佳幸, 松田 豪, 松下 照雄, 小室 裕冉, 中島 鉄夫

    日本放射線技術学会雑誌   46 ( 4 )   674 - 674   1990

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003532196

    CiNii Article

    researchmap

  • 56. Cardiac wall motion analisis using presaturation tagging technique

    木戸屋 栄次, 松田 豪, 小室 裕冉

    Japanese Journal of Radiological Technology   46 ( 10 )   1645 - 1645   1990

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003499885

    CiNii Article

    researchmap

  • MR-3 高速イメージング (演題番号 131〜135)(座長集約)

    松田 豪

    日本放射線技術学会雑誌   46 ( 8 )   1455 - 1456   1990

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003322614

    CiNii Article

    researchmap

  • 417. Usefulness of Fast-Scan Method in Temporomandibular Joint MR Study.

    Matsuda Tsuyoshi, Sugimoto Katsuya, Komuro Hiroyuki, Itoh Syunsuke

    Japanese Journal of Radiological Technology   46 ( 8 )   1388 - 1388   1990

     More details

    Language:Japanese   Publisher:Japanese Society of Radiological Technology  

    DOI: 10.6009/jjrt.KJ00003322539

    CiNii Article

    researchmap

  • 140. 顎関節の CT 画像処理 (2) 臨床応用(CT-3 応用技術)

    杉本 勝也, 松田 豪, 小室 裕冉, 伊東 俊祐, 石井 保雄

    日本放射線技術学会雑誌   46 ( 2 )   256 - 256   1990

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003321933

    CiNii Article

    researchmap

  • 3. MRI における slow flow detection の基礎的検討(MRI-1 流動画像)

    松田 豪, 玉川 洋一, 池野 徹, 小室 裕冉

    日本放射線技術学会雑誌   46 ( 2 )   119 - 119   1990

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003321796

    CiNii Article

    researchmap

  • 1. 小動物用横型スペクトロメーターの利用について : 実験動物を対象とした MRS(MRS の現状と技術的課題)

    松田 豪

    日本放射線技術学会雑誌   46 ( 10 )   1629 - 1629   1990

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003499826

    CiNii Article

    researchmap

  • MRIにおけるslow flow detectionの基礎的検討

    松田 豪

    日本放射線技術学会雑誌   45 ( 9 )   1480 - 1480   1989.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • マルチスライス法におけるGd-DTPAの濃度・信号強度曲線の変化

    松田 豪

    日本放射線技術学会雑誌   45 ( 8 )   1247 - 1247   1989.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 〔臨床MRI入門〕下垂体腺腫(と傍鞍腫瘍)

    周藤 裕治, 木村 一秀, 松田 豪

    画像診断   ( 別冊6 )   33 - 39   1989.7

     More details

    Language:Japanese   Publisher:(株)学研メディカル秀潤社  

    researchmap

  • RESONA (0.35T)の基礎的検討(5) コントラスト比について(2)

    松田 豪

    日本放射線技術学会雑誌   45 ( 2 )   232 - 232   1989.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • マルチスライス法におけるGd-DTPAの濃度・信号強度曲線の変化

    松田 豪

    日本放射線技術学会雑誌   45 ( 3 )   464 - 464   1989

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003108815

    CiNii Article

    researchmap

  • 顎関節のCT画像処理(2) 臨床応用 : 第17回秋季学術大会予稿

    杉本 勝也, 松田 豪, 小室 裕冉, 伊東 俊祐, 石井 保雄

    日本放射線技術学会雑誌   45 ( 9 )   1514 - 1514   1989

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001360244

    CiNii Article

    researchmap

  • MRI におけるslow flow detection の基礎的検討 : 第17回秋季学術大会予稿

    松田 豪, 玉川 洋一, 池野 徹, 小室 裕冉, 石井 靖

    日本放射線技術学会雑誌   45 ( 9 )   1480 - 1480   1989

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001360106

    CiNii Article

    researchmap

  • マルチスライス法におけるGd-DTPAの濃度・信号強度曲線の変化 : MR-7 造影他

    松田 豪, 石森 佳幸, 長谷川 喜也, 池野 徹, 小室 裕冉

    日本放射線技術学会雑誌   45 ( 8 )   1247 - 1247   1989

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001359950

    CiNii Article

    researchmap

  • 16. 骨盤造影検査における超高感度システムの検討 : 撮影II : 一般研究発表 : 中部部会

    長谷川 喜也, 池野 徹, 石森 佳幸, 松田 豪, 小室 裕〓

    日本放射線技術学会雑誌   45 ( 4 )   554 - 554   1989

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001359373

    CiNii Article

    researchmap

  • RESONA(0.35T)の基礎的検討(6) : コントラスト比について(2)

    松田 豪, 木戸屋 栄次, 池野 徹, 小室 裕再

    日本放射線技術学会雑誌   45 ( 2 )   232 - 232   1989

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001359261

    CiNii Article

    researchmap

  • RESONA (0.35T)の基礎的検討(4) コントラスト比について

    松田 豪

    日本放射線技術学会雑誌   44 ( 8 )   1072 - 1072   1988.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 〔MRI 脳・脊髄,頭頸部〕下垂体腺腫(と傍鞍腫瘍)

    周藤 裕治, 木村 一秀, 松田 豪

    画像診断   8 ( 4 )   384 - 390   1988.4

     More details

    Language:Japanese   Publisher:(株)学研メディカル秀潤社  

    researchmap

  • RESONA (0.35T)の基礎的検討(3)

    松田 豪

    日本放射線技術学会雑誌   44 ( 2 )   162 - 162   1988.2

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • MRIによる小児の脳正中構造の発達の定量化

    早川 克己, 松田 豪, 小西 行郎

    CT研究   10 ( 1 )   19 - 23   1988.2

     More details

    Language:Japanese   Publisher:日本脳神経CI学会  

    従来CTでは充分把握出来なかった頭部正中構造-下垂体,橋,脳梁,小脳の計測を行い,加齢による成長過程を検討した.4つの正中構造はそれぞれ異なった発達を示したが小脳虫部が最も早い発達を示し脳梁,橋が次いだ.何れも出生直後から3〜6歳迄の指数関数的な急激な成長と続いてゆっくりした増加が特徴的である.下垂体は平坦なゆっくりした増加であった.発達過程の違いはそれぞれの構造の果す機能の違いと思う.原始的機能を司る小脳が早く発達するのに対し大脳皮質の発達と密接な関係のある橋底部の発育がいくらか緩徐なこともうなづける.下垂体もホルモン分泌機能より男性より女性が,又二次性徴期より妊娠分娩期に大きいことは理解出来る

    researchmap

  • 顎関節のCT画像処理 : 第44回総会学術研究発表抄録 : X-CT-6撮影技術

    杉本 勝也, 松田 豪, 小室 裕冉, 玉川 洋一

    日本放射線技術学会雑誌   44 ( 8 )   1033 - 1033   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001361606

    CiNii Article

    researchmap

  • 顎関節腔造影検査におけるCTの有用性 : 第44回総会学術研究発表抄録 : X-CT-6撮影技術

    杉本 勝也, 山元 秀行, 松田 豪, 池野 徹, 小室 裕冉, 新家 信行

    日本放射線技術学会雑誌   44 ( 8 )   1032 - 1032   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001361605

    CiNii Article

    researchmap

  • 369.顎関節のCT画像処理 : 第44回総会学術大会会員研究発表予稿

    杉本 勝也, 松田 豪, 小室 裕冉, 玉川 洋一

    日本放射線技術学会雑誌   44 ( 3 )   342 - 342   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001360952

    CiNii Article

    researchmap

  • 368.顎関節腔造影検査におけるCTの有用性 : 第44回総会学術大会会員研究発表予稿

    杉本 勝也, 山元 秀行, 松田 豪, 池野 徹, 小室 裕冉, 新家 信行

    日本放射線技術学会雑誌   44 ( 3 )   342 - 342   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001360951

    CiNii Article

    researchmap

  • 101.RESONA(0.35T)の基礎的検討(4) : コントラスト比について : 第44回総会学術大会会員研究発表予稿

    松田 豪, 池野 徹, 小室 裕冉

    日本放射線技術学会雑誌   44 ( 3 )   275 - 275   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001360684

    CiNii Article

    researchmap

  • 56.RESONA(0.35T)の基礎的検討-(3) : MRI : 第15回秋季学術大会学術研究発表抄録

    松田 豪, 池野 徹, 杉本 勝也, 小室 裕冉

    日本放射線技術学会雑誌   44 ( 2 )   162 - 162   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001360520

    CiNii Article

    researchmap

  • 121.RESONA(0.35T)の基礎的検討(5) : コントラスト比について(2) : MR-3(基礎)

    松田 豪, 木戸屋 栄次, 池野 徹, 小室 裕冉

    日本放射線技術学会雑誌   44 ( 9 )   1394 - 1394   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001362119

    CiNii Article

    researchmap

  • RESONA(0.35T)の基礎的検討 : (4)コントラスト比について : 第44回総会学術研究発表抄録 : MR-6装置性能

    松田 豪, 池野 徹, 小室 裕冉

    日本放射線技術学会雑誌   44 ( 8 )   1072 - 1072   1988

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001361645

    CiNii Article

    researchmap

  • 0.35T超電導MRIシステムRESONA

    石井 靖, 奥村 亮介, 松田 豪

    INNERVISION   2 ( 12 )   44 - 47   1987.12

     More details

    Language:Japanese   Publisher:(株)インナービジョン  

    researchmap

  • 筋疾患のMRI

    早川 克己, 山下 敬司, 松田 豪

    映像情報Medical   19 ( 18 )   995 - 996   1987.9

     More details

    Language:Japanese   Publisher:産業開発機構(株)  

    researchmap

  • RESONA (0.35T)の基礎的検討(3)

    松田 豪

    日本放射線技術学会雑誌   43 ( 9 )   1471 - 1471   1987.9

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 実験的脳梗塞のMRIによる検討

    早川 克己, 山下 敬司, 松田 豪

    映像情報Medical   19 ( 18 )   981 - 982   1987.9

     More details

    Language:Japanese   Publisher:産業開発機構(株)  

    実験的脳梗塞モデルを用いて,MRIによる早期診断能を検討した.2時間で37%,3時間にて50%の検出率をえた.Gd-DTPAによるMR enhancementが早期診断能を更に向上させる.この原因として,BBB破壊が示唆された

    researchmap

  • RESONA (0.35T)の基礎的検討(2)

    松田 豪

    日本放射線技術学会雑誌   43 ( 8 )   1126 - 1126   1987.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • RESONA (0.35T)の基礎的検討 各種パラメータについて

    松田 豪

    日本放射線技術学会雑誌   43 ( 4 )   493 - 493   1987.4

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 手術材料が埋め込まれた患者のNMR検査適応について

    松田 豪

    日本放射線技術学会雑誌   43 ( 4 )   496 - 496   1987.4

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • RESONA (0.35T)の基礎的検討(2)

    松田 豪

    日本放射線技術学会雑誌   43 ( 3 )   322 - 322   1987.3

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 149. 顎関節検査法の検討 : X線CTとMRI,アルトログラフィーの比較 : X-CT-1 撮影技術 : 第43回総会会員研究発表予稿

    杉本 勝也, 松田 豪, 池野 徹, 小室 裕冉, 早川 克己

    日本放射線技術学会雑誌   43 ( 3 )   314 - 314   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001362440

    CiNii Article

    researchmap

  • 149. 顎関節検査法の検討 : X線CTとMRI,アルトログラフィーの比較 : X-CT

    杉本 勝也, 松田 豪, 池野 徹, 小室 裕冉, 早川 克己

    日本放射線技術学会雑誌   43 ( 8 )   1069 - 1069   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001363471

    CiNii Article

    researchmap

  • 381. 画像処理システムを利用した骨盤計測について : 画像処理

    上坂 秀樹, 田中 雅人, 池野 徹, 長谷川 嘉也, 松田 豪, 杉本 勝也, 小室 裕冉, 浅田 尚紀

    日本放射線技術学会雑誌   43 ( 8 )   1002 - 1002   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001363404

    CiNii Article

    researchmap

  • 31. 手術材料が埋め込まれた患者のNMR検査適応について : MRI : 第14回秋季学術大会研究発表抄録

    松田 豪, 小室 裕冉

    日本放射線技術学会雑誌   43 ( 4 )   496 - 496   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001362859

    CiNii Article

    researchmap

  • 28. RESONA(0.35T)の基礎的検討 : 各種パラメータについて : 金沢医科大学病院中央放射線部 / 第14回秋季学術大会研究発表抄録 : MRI : 第14回秋季学術大会研究発表抄録

    松田 豪, 池野 徹, 小室 裕冉

    日本放射線技術学会雑誌   43 ( 4 )   493 - 493   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001362856

    CiNii Article

    researchmap

  • 381. 画像処理システムを利用した骨盤計測について : 画像処理-2 ディジタル処理-1 : 第43回総会会員研究発表予稿

    上坂 秀樹, 池野 徹, 長谷川 喜也, 松田 豪, 杉本 勝也, 小室 裕冉, 浅田 尚紀

    日本放射線技術学会雑誌   43 ( 3 )   372 - 372   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001362672

    CiNii Article

    researchmap

  • 182. RESONA(0. 35T)の基礎的検討(2) : MRI-6 性能評価 : 第43回総会会員研究発表予稿

    松田 豪, 池野 徹, 吉村 浩幸, 杉本 勝也, 山元 秀行, 指江 浩之, 小室 裕冉

    日本放射線技術学会雑誌   43 ( 3 )   322 - 322   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001362473

    CiNii Article

    researchmap

  • 182. RESONA(0.35T)の基礎的検討(2) : MRI

    松田 豪, Komuro Hiroyuki, 池野 徹, 吉村 浩幸, 杉本 勝也, 山元 秀行, 指江 浩之, 小室 裕冉, Yamamoto Hideyuki, Sashie Hiroyuki

    日本放射線技術学会雑誌   43 ( 8 )   1126 - 1126   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001363528

    CiNii Article

    researchmap

  • 56.RESONA(0.35T)の基礎的検討ー(3)

    松田 豪, 池野 徹, 杉太 勝也, 小室 裕冉

    日本放射線技術学会雑誌   43 ( 9 )   1471 - 1471   1987

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001364084

    CiNii Article

    researchmap

  • RESONA (0.35T)の基礎的検討 各種パラメータについて

    松田 豪

    日本放射線技術学会雑誌   42 ( 6 )   717 - 717   1986.10

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 手術材料が埋め込まれた患者のNMR検査適応について

    松田 豪

    日本放射線技術学会雑誌   42 ( 6 )   718 - 718   1986.10

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 28.RESONA(0.35T)の基礎的検討 : 各種パラメータについて : MRI

    松田 豪, 池野 徹, 杉本 勝也, 小室 裕冉

    日本放射線技術学会雑誌   42 ( 6 )   717 - 717   1986

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001358129

    CiNii Article

    researchmap

  • 31.手術材料が埋め込まれた患者のNMR検査適応について : MRI

    松田 豪, 小室 裕冉

    日本放射線技術学会雑誌   42 ( 6 )   718 - 718   1986

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00001358132

    CiNii Article

    researchmap

  • 直線断層撮影像の障害陰影消去

    松田 豪

    日本放射線技術学会雑誌   41 ( 5 )   755 - 756   1985.8

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 拡大撮影におけるFCRの有用性

    松田 豪

    日本放射線技術学会雑誌   41 ( 3 )   544 - 545   1985.5

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

    researchmap

  • 494.フィルム法によるヨードフィルタ利用のサブトラクションについて(第41回総会会員研究発表)(画像処理-2)

    西島 昭彦, 田中 雅人, 松田 豪, 小室 裕由

    日本放射線技術学会雑誌   41 ( 5 )   882 - 882   1985

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003107701

    CiNii Article

    researchmap

  • 68.直線断層撮影像の障害陰影消去(第41回総会会員研究発表)(画像処理-1)

    松田 豪, 田中 雅人, 小室 裕冉, 大石 茂雄, 川上 寿昭

    日本放射線技術学会雑誌   41 ( 5 )   755 - 756   1985

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003107280

    CiNii Article

    researchmap

  • 7.拡大撮影におけるFCRの有用性(撮影-1)(中部部会)

    松田 豪, 小室 裕由, 中野 善久

    日本放射線技術学会雑誌   41 ( 3 )   544 - 545   1985

     More details

    Language:Japanese   Publisher:公益社団法人 日本放射線技術学会  

    DOI: 10.6009/jjrt.KJ00003107097

    CiNii Article

    researchmap

▶ display all

Presentations

  • Flip angle measurement by 2D actual flip angle imaging method using Shinnar-Le Roux RF pulse

    Matsuda Tsuyoshi, Ikuko Uwano, Kota Takeda, Yuji Iwadate, Makoto Sasaki

    2019.9 

     More details

    Event date: 2019.9

    Language:English   Presentation type:Poster presentation  

    researchmap

  • 7T pTx較正スキャンにおけるBloch-Siegert法の位相変動:GREとspoiled GREとの比較

    松田 豪

    第46回日本磁気共鳴医学会大会  2018.9 

     More details

    Language:Japanese   Presentation type:Poster presentation  

    researchmap

  • 研究に携わる技術者の視点 Invited

    松田 豪

    日本放射線技術学会第74回総会学術大会  2018.4 

     More details

    Language:Japanese   Presentation type:Symposium, workshop panel (nominated)  

    researchmap

  • 臨床Proton MRS Invited

    松田 豪

    第45回日本磁気共鳴医学会大会  2017.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (invited, special)  

    researchmap

  • 7T RF多チャンネル送信における較正スキャンのB1+補正への影響:GREとspoiled GREとの比較

    松田 豪

    第45回日本磁気共鳴医学会大会  2017.9 

     More details

    Language:Japanese   Presentation type:Poster presentation  

    researchmap

  • 7T 装置における8ch送信コイルと2ch送信コイルによるB1+分布の比較

    松田 豪

    第44回日本磁気共鳴医学会大会  2016.9 

     More details

    Language:Japanese   Presentation type:Poster presentation  

    researchmap

  • GSH検出のためのMEGA-PRESS法の改良

    松田 豪

    第43回日本磁気共鳴医学会大会  2015.9 

     More details

    Language:Japanese   Presentation type:Poster presentation  

    researchmap

  • Delay Encodeを用いたContinuous Arterial Spin Labeling

    松田 豪

    第43回日本磁気共鳴医学会大会  2015.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • メカニズムからMRI検査の危険性を理解する Invited

    松田 豪

    MRI医療安全セミナー  2014.12 

     More details

    Language:Japanese   Presentation type:Public lecture, seminar, tutorial, course, or other speech  

    researchmap

  • 人用7.0 Tesla装置でのSpin EchoシーケンスにおけるRF Shimming機能の追加

    松田 豪

    第42回日本磁気共鳴医学会大会  2014.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Local transmit coilにおけるDWIのコントラスト改善の検討

    松田 豪

    第41回日本磁気共鳴医学会大会  2013.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • TTmappingを用いた3D ASL法

    松田 豪

    第41回日本磁気共鳴医学会大会  2013.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 人用7.0T systemを用いた3D ASLの初期検討

    松田 豪

    第41回日本磁気共鳴医学会大会  2013.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

▶ display all

Industrial property rights

  • 磁気共鳴イメージング装置

    椛沢 宏之, 松田 豪

     More details

    Applicant:ゼネラル・エレクトリック・カンパニイ

    Application no:特願2016-037729  Date applied:2016.2

    Announcement no:特開2017-153573  Date announced:2017.9

    J-GLOBAL

    researchmap

  • 磁気共鳴装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2015-233708  Date applied:2015.11

    Announcement no:特開2017-099512  Date announced:2017.6

    J-GLOBAL

    researchmap

  • 磁気共鳴イメージング装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2012-083442  Date applied:2012.4

    Announcement no:特開2013-212235  Date announced:2013.10

    J-GLOBAL

    researchmap

  • 磁気共鳴装置およびプログラム

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2011-145477  Date applied:2011.6

    Announcement no:特開2013-009900  Date announced:2013.1

    J-GLOBAL

    researchmap

  • 磁気共鳴イメージング装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2011-018315  Date applied:2011.1

    Announcement no:特開2012-157466  Date announced:2012.8

    J-GLOBAL

    researchmap

  • 磁気共鳴イメージング装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2008-319042  Date applied:2008.12

    Announcement no:特開2010-142256  Date announced:2010.7

    J-GLOBAL

    researchmap

  • 磁気共鳴イメージング装置および神経伝達物質定量化方法

    松田 豪, 木村 浩彦

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2008-146664  Date applied:2008.6

    Announcement no:特開2009-291348  Date announced:2009.12

    J-GLOBAL

    researchmap

  • 磁気共鳴イメージング装置および神経伝達物質定量化方法

    松田 豪, 木村 浩彦

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2008-146664  Date applied:2008.6

    Announcement no:特開2009-291348  Date announced:2009.12

    Patent/Registration no:特許第5154311号  Date issued:2012.12

    J-GLOBAL

    researchmap

  • 磁気共鳴イメージング装置、RFパルスの送信方法およびプログラム

    松田 豪, 河合 秀典

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2008-003301  Date applied:2008.1

    Announcement no:特開2009-160342  Date announced:2009.7

    J-GLOBAL

    researchmap

  • 生体組織中の膜タンパク質の水輸送機能の解析用薬剤

    前田 彰彦, 平 博司, 藤本 隆之, 永澤 清, 松田 豪, 橋口 裕二, 中谷 暁

     More details

    Applicant:大陽日酸株式会社, ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー, 日本メジフィジックス株式会社

    Application no:特願2007-084353  Date applied:2007.3

    Announcement no:特開2008-239566  Date announced:2008.10

    J-GLOBAL

    researchmap

  • 位相変化融合画像表示方法および装置

    平野 勝也, 松田 豪, ハスナイン, ハキュー アクター

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2006-334078  Date applied:2006.12

    Announcement no:特開2008-142368  Date announced:2008.6

    J-GLOBAL

    researchmap

  • 位相変化融合画像表示方法および装置

    平野 勝也, 松田 豪, ハスナイン, ハキュー アクター

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2006-334078  Date applied:2006.12

    Announcement no:特開2008-142368  Date announced:2008.6

    Patent/Registration no:特許第5015568号  Date issued:2012.6

    J-GLOBAL

    researchmap

  • 磁気共鳴イメージング装置及びスペクトル取得方法

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2005-362256  Date applied:2005.12

    Announcement no:特開2007-159928  Date announced:2007.6

    J-GLOBAL

    researchmap

  • データ処理装置、データ処理方法、そのデータ処理装置又はデータ処理方法に用いられるエコー画像データを得るための磁気共鳴撮像装置、及び、磁気共鳴撮像方法。

    宮地 利明, 松田 豪

     More details

    Applicant:国立大学法人金沢大学

    Application no:特願2004-343204  Date applied:2004.11

    Announcement no:特開2006-149583  Date announced:2006.6

    J-GLOBAL

    researchmap

  • 磁気共鳴撮影装置およびRF波生成方法

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2003-399285  Date applied:2003.11

    Announcement no:特開2005-152534  Date announced:2005.6

    J-GLOBAL

    researchmap

  • 磁気共鳴信号収集方法、磁気共鳴撮影方法および磁気共鳴撮影装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2003-147142  Date applied:2003.5

    Announcement no:特開2004-344543  Date announced:2004.12

    J-GLOBAL

    researchmap

  • 磁気共鳴撮影装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2003-147142  Date applied:2003.5

    Announcement no:特開2004-344543  Date announced:2004.12

    Patent/Registration no:特許第4297731号  Date issued:2009.4

    J-GLOBAL

    researchmap

  • N—アセチルアスパレート、グルタミンおよびグルタメートの定量化方法並びに磁気共鳴撮像装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2002-319324  Date applied:2002.11

    Announcement no:特開2004-148024  Date announced:2004.5

    J-GLOBAL

    researchmap

  • 磁気共鳴撮像装置および磁気共鳴信号抑制方法

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2002-281988  Date applied:2002.9

    Announcement no:特開2004-113525  Date announced:2004.4

    J-GLOBAL

    researchmap

  • 磁気共鳴撮像装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2002-281988  Date applied:2002.9

    Announcement no:特開2004-113525  Date announced:2004.4

    Patent/Registration no:特許第4130346号  Date issued:2008.5

    J-GLOBAL

    researchmap

  • 医用画像撮影装置

    橋本 浩, 松田 豪, 森谷 浩人, 野崎 敦

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2002-202336  Date applied:2002.7

    Announcement no:特開2004-046489  Date announced:2004.2

    J-GLOBAL

    researchmap

  • 観察対象信号抽出方法およびMRI装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2002-145811  Date applied:2002.5

    Announcement no:特開2003-339660  Date announced:2003.12

    J-GLOBAL

    researchmap

  • 波形データからのスペクトル推定方法、スペクトル推定方法を適用した磁気共鳴映像撮像方法、スペクトル推定方法を適用した磁気共鳴映像撮像装置、およびこれらの方法をコンピュータ上で実行するプログラム

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2001-311917  Date applied:2001.10

    Announcement no:特開2003-116811  Date announced:2003.4

    J-GLOBAL

    researchmap

  • スペクトル推定方法および磁気共鳴映像撮像装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2001-311917  Date applied:2001.10

    Announcement no:特開2003-116811  Date announced:2003.4

    Patent/Registration no:特許第3842607号  Date issued:2006.8

    J-GLOBAL

    researchmap

  • MRI用コイル装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2001-307378  Date applied:2001.10

    Announcement no:特開2003-116808  Date announced:2003.4

    J-GLOBAL

    researchmap

  • 脳血流計測装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2001-284416  Date applied:2001.9

    Announcement no:特開2003-088510  Date announced:2003.3

    J-GLOBAL

    researchmap

  • 脳血流計測装置

    松田 豪

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2001-284416  Date applied:2001.9

    Announcement no:特開2003-088510  Date announced:2003.3

    Patent/Registration no:特許第5143986号  Date issued:2012.11

    J-GLOBAL

    researchmap

  • 磁気共鳴信号受信方法および装置並びに磁気共鳴撮影装置

    松田 豪, 奈部谷 章

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2000-289796  Date applied:2000.9

    Announcement no:特開2002-102199  Date announced:2002.4

    J-GLOBAL

    researchmap

  • 磁気共鳴撮影装置

    松田 豪, 奈部谷 章

     More details

    Applicant:ジーイー・メディカル・システムズ・グローバル・テクノロジー・カンパニー・エルエルシー

    Application no:特願2000-289796  Date applied:2000.9

    Announcement no:特開2002-102199  Date announced:2002.4

    Patent/Registration no:特許第4502488号  Date issued:2010.4

    J-GLOBAL

    researchmap

  • 磁気共鳴信号抑制方法および装置並びに磁気共鳴撮像方法および装置

    松田 豪

     More details

    Applicant:ジーイー横河メディカルシステム株式会社

    Application no:特願平10-269757  Date applied:1998.9

    Announcement no:特開2000-093403  Date announced:2000.4

    J-GLOBAL

    researchmap

▶ display all

Research Projects

  • Development of a Highly Accurate Measurement Technique for Transmitting Field Distribution in Ultra-High Field 7T MRI Using Phase-Sensitive Imaging Method

    Grant number:23K11876

    2023.4 - 2026.3

    System name:Grants-in-Aid for Scientific Research

    Research category:Grant-in-Aid for Scientific Research (C)

    Awarding organization:Japan Society for the Promotion of Science

      More details

    Grant amount:\4420000 ( Direct Cost: \3400000 、 Indirect Cost:\1020000 )

    researchmap

  • 血管信号抑制ASLによる非侵襲脳循環測定の精度向上技術の開発

    Grant number:20K09397

    2020.4 - 2023.3

    System name:科学研究費助成事業

    Research category:基盤研究(C)

    Awarding organization:日本学術振興会

    松田 豪, 小笠原 邦昭, 佐々木 真理, 上野 育子

      More details

    Grant amount:\4420000 ( Direct Cost: \3400000 、 Indirect Cost:\1020000 )

    開発したDelay Alternating with Nutation for Tailored Excitation (DANTE)法とMotion Sensitized Driven Equilibrium (MSDE) 法の2種類の血管信号抑制パルス(vessel suppression: VS)を使用したArterial Spin Labeling (ASL)法を3名のボランティアで撮像し、信号を解析した。ASL元画像の静止部の信号強度比は、昨年度に実施したファントム実験と同様の傾向の結果が得られ、DANTE法はMSDE法に比べ高い信号雑音比(SNR)を示した。これはMSDE法では画像収集までのタイミングが延長することで信号強度の低下が生じることが原因と考えられた。またMSDE法の静止組織内の水信号低下効果も、信号強度低下の一因として考えられる。信号抑制効果に関してはDASNTE法が均一な抑制効果を示した。これはDANTE pulseで使用されるラジオ波(RF)の強度がMSDE法に比べて低いために、RF波の不均一性が画像に及ぼす効果が低いことと、MSDE法では複数のRF波から信号を生成するためにRF波の不均一効果が重積することにより信号強度がDANTE法よりも不均一になったと推測される。
    ボランティアによるASL画像では、ファントム実験同様の傾向の結果が得られた。DANTE2とDANTE4の比較ではDANTE4で高い信号強度の画像を得ることができた。従って以降の検討ではDANTE4を使用した。もやもや病疾患を有する2名のボランティアによるASL画像でも、ファントム実験ならびにボランティア同様、DANTE法がMSDE法よりも高い信号強度の画像を得ることができた。しかしラベルされた血液による残存血管内信号は両手法でも目立たなかったために、十分に検討する事ができなかった。

    researchmap

  • 超高磁場MRIの多チャンネルRF送信における局所磁場分布の高速取得法の開発

    Grant number:18H00483

    2018

    System name:科学研究費助成事業

    Research category:奨励研究

    Awarding organization:日本学術振興会

    松田 豪

      More details

    Grant amount:\530000 ( Direct Cost: \530000 )

    【研究目的】磁気共鳴診断装置(MRI)では送信ラジオ波(RF)と人体の干渉による局所磁場(B1+)分布の不均一が発生し、信号の均一性やコントラストの劣化が生じる。この問題を解決する目的で、複数のRFを個別に調整して送信する多チャンネルRF送信技術(pTx)が開発された。pTxでは、各被検体ごとに撮影断面のB1+分布を計測する必要があるが、3次元(3D)actual flip angle(AFI)法などの従来手法では長時間を要するため、検査時間の大幅な延長につながっていた。そこで高速にB1+分布を計測可能とする手法を確立する。
    【研究方法】スライスプロファイルを改善するShinnar-Le Roux(SLR)アルゴリズムのRFパルスによる2次元(2D)AFI法を開発し、FA測定精度を3D-AFI法と比較し特性を評価した。2D-AFIでは3種類の帯域(841, 1842, 2549Hz)のSLR-RFパルスを、3D-AFIではハードパルスを使用した。ファントムとボランティアを対象に5種類のFA(10, 15, 30, 50, 70度)と2種類のスライス厚(5mm, 10mm)にて撮像し、各種撮像条件下での2D-AFIと3D-AFIによる面内FA測定値を比較評価した。ファントムでは3種類のT1値(435, 1027, 2243ms)での撮像を実施した。2D-AFIの撮像時間は2回加算時で11秒、3D-AFIは1回加算時で2分17秒であった。
    【研究成果】ファントムではT1値が435msの場合、2D-AFIと3D-AFIとの間には各撮像FAで異なる傾き・切片を持つ一次関数が成り立ったが、T1値が長くなるほどT1緩和の影響により高いFAで線形性から逸脱する傾向となった。また、スライス厚は5mmの方が3D-AFIに近いFA測定値を示した。ボランティアでは撮像FAが30度以上でスライス厚5mm、並びに1842Hz以上の帯域のSLR-RFパルスを使用した場合、T1値の長い脳脊髄液以外の脳領域で3D-AFIと近似したFA分布を約12倍の高速化で取得できた。pTxに必要な撮像時間を短縮することが可能となり、今後の臨床応用へつなげることができる。

    researchmap