Updated on 2026/11/24

写真a

 
OYANAGI Kanako
 
Organization
University Medical and Dental Hospital Diagnostic Radiology Assistant Professor
Title
Assistant Professor
External link

The Best Research Achievement in Research Career

    • 【Papers】 Computed tomography findings of acute gastric peptic ulcer.  2021.3

Degree

  • 学士 ( 2022.3   新潟大学 )

  • 修士 ( 2011.3   秋田大学 )

Research History

  • Niigata University   Diagnostic Radiology, University Medical and Dental Hospital   Assistant Professor

    2026.5

 

Papers

  • Registration-guided GAN Synthesis of Virtual Contrast-enhanced Thoracic CT for Hilar and Mediastinal Lymph Node Detection International journal

    Motohiko Yamazaki, Kanako Oyanagi, Yuma Fuzawa, Kyoryoku You, Tetsuya Nomura, Takuya Yagi, Naoya Koizumi, Akiko Tasaki, Masaki Tominaga, Ibuki Namihira, Satoru Kobayashi, Hiroyuki Ishikawa

    Radiology: Cardiothoracic Imaging   8 ( 5 )   e269001   2026.8

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Purpose To develop and evaluate a registration-guided generative adversarial network (Reg-GAN) that synthesizes virtual contrast-enhanced CT (vCECT) from noncontrast CT (NCCT) images and to assess its utility in detecting enlarged hilar and mediastinal lymph nodes. Materials and Methods In this retrospective study, data from 700 patients for training, 100 patients for internal testing, and 63 patients for external testing were used to construct Reg-GAN, which aligns synthesized vCECT with true CECT (tCECT) images during training. Image quality was compared among Reg-GAN, Non-Reg-GAN, and a publicly available GAN (Public GAN). Enlarged lymph nodes were defined by a 10-mm short-axis diameter threshold, and their detectability was evaluated. Wilcoxon signed rank and DeLong tests were used. Results In both the internal and external test sets, Reg-GAN-generated vCECT images were most similar to tCECT, as indicated by lower median values of the mean absolute error than Non-Reg-GAN and Public GAN (internal test, 13.60 vs 17.84 and 15.52, respectively, both P < .001; external test, 14.91 vs 19.49 and 16.37, respectively, both P < .001). In the reader study using the external test set, adding vCECT to NCCT improved area under the receiver operating characteristic curve values for detecting enlarged lymph nodes, particularly for the two most experienced radiologists, from 0.81 to 0.90 and from 0.74 to 0.88 (both P < .05). Conclusion Reg-GAN synthesized higher-quality vCECT images from NCCT images than Non-Reg-GAN and Public GAN. Adding vCECT images improved the detectability of enlarged lymph nodes, supporting the potential utility of vCECT in patients contraindicated for contrast agent administration or screening settings. Keywords: Generative Adversarial Network, Virtual Contrast-enhanced CT, Registration-guided GAN, Hilar and Mediastinal Lymph Nodes, Noncontrast CT, Deep Learning Supplemental material is available for this article. © RSNA, 2026.

    DOI: 10.1148/ryct.250521

    PubMed

    researchmap

  • A case of small intestinal fixation failure International journal

    Kanako Oyanagi, Yosuke Horii, Hiroyuki Ishikawa, Kazuyasu Takizawa

    BJR|Case Reports   10 ( 6 )   uaae046   2024.11

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    A 77-year-old woman underwent CT to evaluate haematemesis. The images showed that the third part of the duodenum flexed steeply on the right side of the aorta and ran caudally, without crossing anterior to the aorta. The duodenal-jejunal junction and jejunum were located on the patient's right side. Upper gastrointestinal endoscopy revealed a laceration at the gastric cardia, and a diagnosis of Mallory-Weiss syndrome was made. Repeat CT 7 days later revealed that the abnormal positioning of the intestinal tract had resolved spontaneously. Two months later, the patient experienced another episode of haematemesis, and CT revealed repeat deviation of the duodenal-jejunal junction and jejunum to her right side. Upper gastrointestinal endoscopy revealed another laceration at the gastric cardia, as in the previous study. On the basis of the initial CT findings showing the duodenal-jejunal junction in the right hemi-abdomen, intestinal malrotation was suspected. However, because the jejunum deviated repeatedly to the right side but resolved spontaneously, we diagnosed dysplasia of the ligament of Treitz. Laparotomy revealed a formed ligament of Treitz; however, fixation in the upper jejunum was incomplete. Additionally, CT revealed that the anterior pararenal space was loosely fixed and mobile. These factors may have caused the right-sided deviation of the small intestine. In this case, the third part of the duodenum likely flexed on the right side of the aorta, causing an obstruction that resulted in repeat vomiting episodes and Mallory-Weiss syndrome.

    DOI: 10.1093/bjrcr/uaae046

    PubMed

    researchmap

  • Computed tomography findings of acute gastric peptic ulcer. International journal

    Kanako Oyanagi, Takeshi Higuchi, Norihiko Yoshimura

    Clinical imaging   71   77 - 82   2021.3

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    PURPOSE: To report the computed tomography (CT) findings of acute peptic ulcer disease (PUD) and to evaluate the usefulness of contrast media for diagnosis. METHODS: This retrospective study included 51 patients diagnosed with acute gastric peptic ulcer by endoscopy. Using a κ analysis, two radiologists independently reviewed contrast-enhanced emergency CTs performed within 24 h of endoscopy. Evaluation findings included low-attenuation wall thickening, focal wall thickening, focal luminal outpouching, perigastric fat stranding, ascites, adjacent lymphadenopathy, and high-density gastric contents. Of the 51 patients, 48 underwent both non-contrast-enhanced and contrast-enhanced CT, and two radiologists also evaluated the presence or absence of these findings on a non-contrast-enhanced CT. McNemar's test was used to evaluate the contrast media's usefulness. RESULTS: Interobserver variability of perigastric fat stranding revealed substantial agreement between evaluators, and other findings had almost perfect agreement. High-density gastric contents were the most recognized findings (60%). Low-attenuation focal wall thickening and focal luminal outpouching were observed in relatively large numbers (~50%) of the cases on contrast-enhanced CT. The CT examinations using contrast media provided significantly higher detectability of low-attenuation wall thickening and focal luminal outpouching than CT examinations without using contrast media. CONCLUSION: Acute PUD can be suspected in patients with nonspecific abdominal symptoms in whom emergency CT shows high-density gastric contents, focal low-attenuation wall thickening, and/or focal luminal outpouching. Our study showed that contrast media are useful for diagnosis.

    DOI: 10.1016/j.clinimag.2020.10.044

    PubMed

    researchmap

  • Quantitative 3D Shape Analysis of CT Images of Thymoma: A Comparison With Histological Types. International journal

    Motohiko Yamazaki, Kanako Oyanagi, Hajime Umezu, Takuya Yagi, Hiroyuki Ishikawa, Norihiko Yoshimura, Hidefumi Aoyama

    AJR. American journal of roentgenology   214 ( 2 )   341 - 347   2020.2

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    OBJECTIVE. The purpose of this study is to differentiate between low- and high-risk types of thymoma using quantitative 3D shape analysis of CT images. MATERIALS AND METHODS. This retrospective study included 44 patients with a pathologic diagnosis of thymoma. Two radiologists semiautomatically contoured CT images of the tumors and evaluated 3D shape parameters-namely, quantitative indicators of surface smoothness, including sphericity, ellipsoidality, and discrete compactness. The visual CT findings that were analyzed included longest diameter, shape (round-oval, lobulated, or irregular), calcification, cystic or necrotic changes, and enhancement pattern (homogeneous or heterogeneous). The difference and discriminating performance between low-risk (types A, AB, and B1) and high-risk (types B2 and B3) thymomas were statistically assessed. Interobserver agreement was determined using the concordance correlation coefficient. RESULTS. Twenty-three low-risk and 21 high-risk thymomas were identified on the basis of pathologic findings. The median values of sphericity and ellipsoidality were significantly higher for low-risk thymomas than for high-risk thymomas (for sphericity, 0.566 vs 0.517; for ellipsoidality, 0.941 vs 0.875; p < 0.05 for both). The AUC values of sphericity and ellipsoidality were 0.704 and 0.712, respectively. The best cutoff values were 0.528 and 0.919 for sphericity and ellipsoidality, respectively. Risk assessment combining these cutoff values and the mode of tumor detection (incidental detection or detection based on the presence of symptoms) improved the AUC value to 0.856 (sensitivity, 81.0% [17 of 21 patients]; specificity, 82.6% [19 of 23 patients]). All 3D shape parameters showed almost perfect interobserver agreement (concordance correlation coefficient, > 0.90). The visual CT findings were not significantly different between low- and high-risk thymomas (p > 0.05 for all). CONCLUSION. Quantitative 3D shape analysis has excellent reproducibility, and combining this technique with information on the detection mode helps differentiate low- from high-risk thymomas.

    DOI: 10.2214/AJR.19.21844

    PubMed

    researchmap

  • [A Case of Squamous Cell Carcinoma with Negative Conversion of ER Status after Endocrine Therapy in an Elderly Woman].

    Yuka Endo, Eiko Sakata, Mai Sato, Kouko Yoshida, Hideki Hashidate, Hiroyuki Shibuya, Kanako Oyanagi, Chihiro Sato, Takeshi Higuchi, Haruhiko Makino

    Gan to kagaku ryoho. Cancer & chemotherapy   45 ( 13 )   2354 - 2356   2018.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    We report the case ofan elderly patient with squamous cell carcinoma(SCC)ofthe breast, which showed negative conversion after endocrine therapy. An 82-year-old woman with a diagnosis ofER -positive SCC(cT1N0M0, StageⅠ)received primary endocrine therapy with 5 hormonal medicines. Following the endocrine therapy, she underwent mastectomy and axillary node resection. Histological examination confirmed a diagnosis of ER-negative SCC. At 10 months after the operation, she was doing well with no evidence ofdisease without postoperative adjuvant therapy. Thus, clinicians should be aware that the ER status may change after primary endocrine therapy. For elderly patients with breast cancer, it is important to be aware that primary endocrine therapy can become ineffective due to ER-negative conversion and aging due to prolonged treatment.

    PubMed

    researchmap

  • What Is Benign Posttraumatic Pseudopneumoperitoneum? Where Does the Gas Come From? International journal

    Takeshi Higuchi, Naoya Takahashi, Kanako Oyanagi

    AJR. American journal of roentgenology   211 ( 1 )   W77   2018.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.2214/AJR.18.19552

    PubMed

    researchmap

▶ display all