2026/11/24 更新

写真a

クマガイ カズキ
熊谷 和樹
KUMAGAI Kazuki
所属
医歯学総合病院 放射線診断科 助教
職名
助教
外部リンク

学位

  • 博士(医学) ( 2024年3月   新潟大学 )

  • 学士(医学) ( 2013年3月   新潟大学 )

経歴

  • 新潟大学   医歯学総合病院 放射線診断科   助教

    2026年6月 - 現在

 

論文

  • Quantitative MR texture analysis for the differentiation of uterine smooth muscle tumors with high signal intensity on T2-weighted imaging. 国際誌

    Kazuki Kumagai, Takuya Yagi, Motohiko Yamazaki, Akiko Tasaki, Mina Asatani, Hiroyuki Ishikawa

    Medicine   102 ( 31 )   e34452   2023年8月

     詳細を見る

    記述言語:英語   掲載種別:研究論文(学術雑誌)  

    The purpose of this study was to distinguish leiomyosarcomas/smooth muscle tumors of uncertain malignant potential (STUMP) from leiomyomas with high signal intensity (SI) on T2-weighted imaging (T2WI) using quantitative MR texture analysis combined with patient characteristics and visual assessment. Thirty-one leiomyomas, 2 STUMPs, and 6 leiomyosarcomas showing high SI on T2WI were included. First, we searched for differences in patient characteristics and visual assessment between leiomyomas and leiomyosarcomas/STUMPs. We also compared the MR texture on T2WI and the apparent diffusion coefficient (ADC) to identify differences between leiomyomas and leiomyosarcomas/STUMPs. In the univariate analysis, significant differences between leiomyomas and leiomyosarcomas/STUMPs were observed in age, menopausal status, margin, hemorrhage, long diameter, T2-variance, T2-volume, ADC-variance, ADC-entropy, ADC-uniformity, ADC-90th and 95th percentile values, and ADC-volume (P < .05, respectively). There were significantly more postmenopausal patients with leiomyosarcomas/STUMPs than with leiomyomas, and leiomyosarcomas/STUMPs had more irregular margins, more frequent presence of hemorrhage and exhibited larger tumor diameters, T2-volume, T2-variance, ADC-volume, ADC-variance, ADC-entropy, and higher ADC-90th and 95th percentile values but lower ADC-uniformity. Multivariate analyses revealed that the independent differentiators were menopausal status, hemorrhage and ADC-entropy (P < .05, respectively). The area under the curve obtained by combining the 3 items was 0.980. The best cutoff value for ADC-entropy was 9.625 (sensitivity: 100%, specificity: 58%). The combination of menopausal status, hemorrhage, and ADC-entropy can help accurately distinguish leiomyosarcomas/STUMPs from leiomyomas with high SI on T2WI; however, external validation in a larger population is required because of the small sample size of our study.

    DOI: 10.1097/MD.0000000000034452

    PubMed

    researchmap

  • Low Tube Voltage Computed Tomography Venography for Patients With Deep Vein Thrombosis of the Lower Extremities - A Comparison With Venous Ultrasonography.

    Tatsuhiko Sato, Norihiko Yoshimura, Yosuke Horii, Motohiko Yamazaki, Ken Sato, Kazuki Kumagai, Hiroyuki Ishikawa

    Circulation journal : official journal of the Japanese Circulation Society   85 ( 4 )   369 - 376   2021年3月

     詳細を見る

    記述言語:英語   掲載種別:研究論文(学術雑誌)  

    BACKGROUND: Low tube voltage computed tomography venography (CTV) can be expected to increase imaging contrast and decrease radiation exposure by using iterative reconstruction (IR). This study evaluated the diagnostic ability of low tube voltage CTV with IR for deep vein thrombosis (DVT), compared to ultrasonography (US). METHODS AND RESULTS: Two experienced radiologists retrospectively reevaluated the CTV data of 55 of 318 consecutive patients suspected of having DVT or pulmonary embolism between December 2015 and April 2017. The 55 patients had undergone both low tube voltage CTV and US (within 1 day before or after CTV). The lower extremity veins were divided into 10 segments. The DVT forms were categorized into 3 types: complete, concentric, and eccentric. We analyzed the 534 overall segments (16 segments excluded in US) measured using both CTV and US. The sensitivity-specificity was overall 73.3-90.0%, for femoropopliteal, it was 90.0-93.2%, and for the calf, it was 71.1-87.2%. The diagnostic accuracy between the 'eccentric only' and 'others' groups focusing on DVT forms was compared, and significant differences were revealed, especially in the muscular vein. CONCLUSIONS: The DVT diagnostic ability above the knee was comparable between low tube voltage CTV with IR and conventional CTV, and the radiation dose was reduced. It was suggested that eccentric DVT measured by CTV tend to be a false-positive, especially in the calf muscular vein.

    DOI: 10.1253/circj.CJ-20-0416

    PubMed

    researchmap