Updated on 2024/12/21

写真a

 
ODA Masafumi
 
Organization
Social Cooperation Promotion Organization . Professor
Graduate School of Science and Technology Advanced Materials Science and Technology Professor
Faculty of Engineering Department of Engineering Professor
Title
Professor
▶ display Profile on researchmap
External link

Degree

  • Doctor (Engineering) ( 1996.3   Niigata University )

  • Master of Engineering ( 1988.3   Niigata University )

  • Bachelar of Engineering ( 1986.3   Niigata University )

Research Areas

  • Manufacturing Technology (Mechanical Engineering, Electrical and Electronic Engineering, Chemical Engineering) / Machine elements and tribology

  • Manufacturing Technology (Mechanical Engineering, Electrical and Electronic Engineering, Chemical Engineering) / Design engineering

  • Manufacturing Technology (Mechanical Engineering, Electrical and Electronic Engineering, Chemical Engineering) / Mechanics of materials and materials

  • Life Science / Biomaterials

  • Life Science / Biomedical engineering

  • Life Science / Medical systems

  • Life Science / Rehabilitation science

▶ display all

Research History (researchmap)

  • Niigata University   Faculty of Engineering Department of Engineering   Professor

    2019.4

      More details

  • Niigata University   Institute for Social Innovation and Cooperation   Professor

    2016.4

      More details

  • Niigata University   Institute for Research Collaboration and Promotion Center for Intellectual Property Creation   Professor

    2011.4 - 2016.3

      More details

  • Niigata University   Graduate School of Science and Technology Industrial Science and Technology   Professor

    2004.4

      More details

  • Niigata University   Social Cooperation Promotion Organization Center for Cooperative Research   Professor

    2003.9 - 2011.3

      More details

  • The Polytechnic University of Japan   Associate Professor (as old post name)

    2003.4 - 2003.8

      More details

  • Kinki Polytechnic College   Associate Professor (as old post name)

    2001.4 - 2003.3

      More details

  • The Polytechnic University of Japan   Associate Professor (as old post name)

    1997.7 - 2001.3

      More details

  • The Polytechnic University of Japan   Lecturer

    1997.4 - 1997.6

      More details

  • Niigata Polytechnic College   Lecturer

    1992.4 - 1997.3

      More details

  • Industrial Research Institute of Niigata Prefecture   Researcher

    1991.4 - 1992.3

      More details

  • Industrial Research Institute of Niigata Prefecture

    1989.4 - 1991.3

      More details

▶ display all

Research History

  • Niigata University   Social Cooperation Promotion Organization   Professor

    2023.4

  • Niigata University   Advanced Materials Science and Technology, Graduate School of Science and Technology   Professor

    2023.4

  • Niigata University   Faculty of Engineering Department of Engineering   Professor

    2019.4

  • Niigata University   Institute for Social Innovation and Cooperation   Professor

    2016.4 - 2018.3

  • Niigata University   Institute for Research Collaboration and Promotion Center for Intellectual Property Creation   Professor

    2011.4 - 2016.3

  • Niigata University   Graduate School of Science and Technology Industrial Science and Technology   Professor

    2004.4 - 2023.3

  • Niigata University   Center for Cooperative Research   Professor

    2003.9 - 2011.3

▶ display all

Education

  • Niigata University   Graduate School, Division of Science and Technology

    - 1996.3

      More details

    Country: Japan

    researchmap

  • Niigata University   Graduate School, Division of Engineering

    - 1988.3

      More details

    Country: Japan

    researchmap

  • Niigata University   Faculty of Engineering

    - 1986.3

      More details

    Country: Japan

    researchmap

Professional Memberships

  • Intellectual Property Association of Japan

      More details

  • The Japanese Society for Wellbeing Science and Assistive Technology

      More details

  • THe Society of Life Support Technology

      More details

  • The Japanese Society for Non-Destructive Inspection

      More details

  • Japanese Society of Tribologist

      More details

  • The Japan Society of Mechanical Engineers

      More details

▶ display all

 

Papers

  • Development of Work-sheet for Setup of Issue in collaboration with Business and Academic Manager on Internship for Problem Solving

    Takasawa, Yojiro, Oda, Masafumi, Kourakata, Itaru, Ueda, Yasutaka, Nakamura, Fumi

    10   10 - 15   2023.3

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)  

    CiNii Books

    researchmap

  • Bone fracture analysis for calcaneus

    ABE Yoshitaka, SASAGAWA Keisuke, ODA Masafumi, SHIOTA Naofumi

    The Proceedings of Mechanical Engineering Congress, Japan   2022   J026-01   2022

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    Calcaneus fractures are injuries caused by sprains, fall down, falls from high places, or traffic accidents and characterized by the tendency for pain to remain. One of the causes of this pain is poor reduction. In the Essex-Lopresti classification, which is one of the calcaneus fracture classifications, the fracture patterns of calcaneus fractures are roughly divided into two types, tongue type and joint depression type, and it has been suggested that the fracture patterns differ depending on the mechanical condition at the time of injury. Thus, it is important to perform accurate reduction by clarifying the relationships between the difference in mechanical condition at the time of injury and the fracture pattern, which is thought to lead to early healing. Therefore, in this study, it was investigated whether the fracture pattern as seen in the calcaneus fracture classification can be reproduced by considering bone fracture in the finite element analysis for the calcaneus. Furthermore, we investigated the usefulness of this analysis method for clarifying the relationships between the difference in mechanical condition at the time of injury and the fracture pattern. As a result, we indicated that the fracture pattern corresponding to calcaneus fracture classification could be reproduced by bone fracture analysis. In addition, it was suggested that this analysis method is useful for clarifying the relationships between the difference in mechanical condition at the time of injury and the fracture pattern, since the results based on this analysis was consistent with the contents described in the Essex-Lopresti classification.

    DOI: 10.1299/jsmemecj.2022.j026-01

    researchmap

  • Reflections and Prospects; Problem-based Learning and Co-op Education in Undergraduate Engineering Programs focusing on Incongruity between Student’s Major and Company’s Field of Activity

    小浦方 格, 尾田 雅文, 若林 悦子, 高澤 陽二郎

    The Proceedings of Mechanical Engineering Congress, Japan   2022   S401 - 13   2022

     More details

    Publishing type:Research paper (scientific journal)   Publisher:Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmemecj.2022.s401-13

    researchmap

  • 骨破壊を考慮した大腿骨転子部骨折のメカニズム解析

    阿部 佳峻, 笹川 圭右, 尾田 雅文, 佐藤 朗, 原 利昭

    臨床バイオメカニクス   42   21 - 27   2021.10

     More details

    Language:Japanese   Publisher:日本臨床バイオメカニクス学会  

    大腿骨転子部骨折には多様な骨折パターンが存在している。多くの臨床的分類は骨折線の位置や粉砕の程度により分類されている。しかし、なぜこのような骨折になるかについては言及されていない。そこで、外力の加わり方(転倒状況)により骨折パターンが異なることを有限要素(FE)解析により解明することを試みた。転倒を想定したFE解析は、従来、主に静的に解析した例が多く、骨折線の進展や骨片の転位等を含めた検討は困難である。したがって、これら骨破壊過程の再現精度向上は解決を要する課題である。本研究は、大腿骨FEモデルを対象とし、転倒を想定した動的FE解析に骨破壊を考慮することで、転倒状況と骨折パターンの関係を調査した。本FE解析で得られた結果は、3D-CT中野分類の一部と類似した。したがって、本手法は、転倒状況と骨折パターンの関係を調べるのに有効であることが示唆された。(著者抄録)

    researchmap

  • Examination of femoral trochanteric fracture pattern using bone fracture analysis

    ABE Yoshitaka, SASAGAWA Keisuke, ODA Masafumi, SATO Akira

    The Proceedings of Mechanical Engineering Congress, Japan   2021   J023-20   2021

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    Elderly people with osteoporosis are injured proximal femur fracture by low energy forces of trauma such as falling from standing. Proximal femoral fracture is likely to reduce activities of daily living (ADL) and quality of life (QOL) because of loss of the walking ability of patients. Thus, early fracture healing is very important. Trochanteric fracture, which are classified as proximal femoral fracture, has a wide variety of fracture patterns for each patient. These fracture patterns are thought to be due to differences in patient-specific bone information such as bone mineral density (BMD) and bone morphology. The aim of this study is to reproduce the fracture line of trochanteric region by applying bone fracture to the dynamic finite element analysis (FEA) assuming a specific fall situation using FE model with subject-specific bone information. The fracture patterns of three subjects were investigated.

    DOI: 10.1299/jsmemecj.2021.j023-20

    researchmap

  • Analysis of fracture pattern for intertrochanteric femur fracture

    Yoshitaka ABE, Keisuke SASAGAWA, Masafumi ODA, Akira SATO

    The Proceedings of Conference of Hokuriku-Shinetsu Branch   2021.58   D032   2021

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    Elderly people are more likely to have the proximal femur fractures because of osteoporosis and so on, even with a slight external force due to a fall. Intertrochanteric fractures, which is one of the proximal femur fractures, have a wide variety of fracture patterns. A suitable treatment is required for each fracture pattern. To investigate the relationship between fall situation and fracture pattern leads to understand these fracture conditions and is important for early recovery. The aim of this study was to investigate the repeatability of the intertrochanteric fracture pattern using dynamic FE analyses in consideration of failure of bone element. As a result of the analysis, the fracture pattern of the intertrochanteric area of the femur similar to that of Type I, 3-part A of the 3DCT classification was obtained.

    DOI: 10.1299/jsmehs.2021.58.d032

    CiNii Article

    researchmap

  • 骨頭外反型や大腿骨転子貫通骨折と呼称される整復困難な転子部骨折についての破壊力学的考察

    佐藤 朗, 湊 泉, 野崎 あさみ, 原 利昭, 笹川 圭右, 尾田 雅文

    整形・災害外科   63 ( 12 )   1713 - 1719   2020.11

     More details

    Language:Japanese   Publisher:金原出版(株)  

    <文献概要>骨頭外反型や転子貫通骨折と呼称される特殊な転子部骨折がある。その特徴は大転子と小転子の頂部を結ぶ骨折線を認め,通常の転子部骨折に認められる転子間窩の骨折を認めないことである。5年間に手術を行った転子部骨折267例中2例に本骨折を認めた。本骨折の3D-CTを破壊力学的に検討した。通常の転子部骨折では転倒し大転子部を強打すると,転子間窩外側部に圧縮応力が集中し骨折が発生する。ほぼ同時に頸部基部前内側部付近が引張応力により骨折していくと考えられる。本骨折では良好な骨質で大転子部に大きな衝撃負荷が加わると,頸部基部前内側部に引張応力により骨折が発生する。この骨折は,引張応力が集中する突出部(後方は小転子頂部から転子間稜,前方は転子間線)に沿って裂けていき,大転子頂部に達したと考えられる。衝撃的負荷による引張応力によって発生し完成された骨折であり,圧縮応力による転子間窩の骨折は発生しなかったと考えられる。

    researchmap

  • Investigation of fracture mechanism for calcaneus

    TAKAOKA Go, SASAGAWA Keisuke, ODA Masafumi, SHIOTA Naofumi, ABE Yoshitaka

    The Proceedings of Mechanical Engineering Congress, Japan   2020   J02116   2020

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    The calcaneus, the heel bone at the foot, is one of the most important bones for weight bearing. This bone supports almost the entire weight of the body when it contacts on the ground. Younger people suffer calcaneus fractures due to larger external forces such as a fall form a height or an accident while driving. However, calcaneus fracture in the elderly are often suffered by small external forces. Calcaneus fracture in the elderly have increased in recent years. For the proper treatment of calcaneus fractures, it is important to understand the fracture mechanism. The purpose of this study was to examine the risk of fracture of the calcaneus by performing FE analysis. A finite element (FE) model of the calcaneus was constructed based on CT images of the foot, and FE analysis was performed under three load conditions.

    DOI: 10.1299/jsmemecj.2020.j02116

    CiNii Article

    researchmap

  • 大腿骨転子下骨折の骨折部固定性に及ぼす髄内釘長さの生体力学的評価

    笹川 圭右, 佐野 匠, 尾田 雅文, 塩田 直史, 佐藤 徹

    臨床バイオメカニクス   40   45 - 52   2019.10

     More details

    Language:Japanese   Publisher:日本臨床バイオメカニクス学会  

    転子下骨折の治療において、適切な髄内釘インプラントの長さを選択するためには、骨折治療への影響を力学的・臨床的の双方から検討を行う必要がある。本研究では、転子下骨折の骨折部固定性について、髄内釘インプラントの長さによる影響を有限要素(FE)解析によって比較検討することを目的とした。転子下骨折の一分類手法であるSeinsheimer分類のType II A、II BおよびII Cに基づいた3種類の骨折モデルを対象とし、髄内釘が埋植された転子下骨折FEモデルをそれぞれ構築した。髄内釘インプラントには異なる長さをもつロング型、ミドル型、ショート型の3種類を使用した。解析の結果、仮骨部に生じる圧縮応力領域が広範囲であることによる骨髄合促進や、応力遮蔽の抑制への期待、さらに侵襲性の観点からミドル型の髄内釘インプラントの有効性が示唆された。(著者抄録)

    researchmap

    Other Link: https://search.jamas.or.jp/index.php?module=Default&action=Link&pub_year=2019&ichushi_jid=J05471&link_issn=&doc_id=20191009100008&doc_link_id=%2Fcx9biomc%2F2019%2F004000%2F009%2F0045-0052%26dl%3D0&url=https%3A%2F%2Fwww.medicalonline.jp%2Fjamas.php%3FGoodsID%3D%2Fcx9biomc%2F2019%2F004000%2F009%2F0045-0052%26dl%3D0&type=MedicalOnline&icon=https%3A%2F%2Fjk04.jamas.or.jp%2Ficon%2F00004_2.gif

  • Influence on blood flow improvement effect of lower limb using automatic CPM device of ankle joint

    YOKOYAMA Shohei, SASAGAWA Keisuke, ODA Masafumi, HIRUKAWA Hiroshi

    The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2019.32   2E33   2019

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmebio.2019.32.2e33

    CiNii Article

    researchmap

  • Influence of intramedullary nail diameter for fixation stability of subtrochanteric femoral fracture

    SANO Takumi, SASAGAWA Keisuke, ODA Masafumi, SHIOTA Naofumi

    The Proceedings of Conference of Hokuriku-Shinetsu Branch   2019 ( 0 )   D014   2019

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmehs.2019.56.D014

    CiNii Article

    researchmap

  • Influence of intramedullary nail length for femoral subtrochanteric fracture model Reviewed

    SANO Takumi, SASAGAWA Keisuke, ODA Masafumi, SHIOTA Naofumi

    The Proceedings of Mechanical Engineering Congress, Japan   2019 ( 0 )   J02328P   2019

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    <p>Intramedullary nail fixation is one of the useful treatments for subtrochanteric fracture. In many cases, long type of intramedullary nail is applied to treatment of subtrochanteric fractures. A middle intramedullary nail, which has an intermediate length between long type and short type, was developed because of the viewpoint of minimally invasive. It is important to examine biomechanical influences on length and diameter of the intramedullary nail systems subjected to various loads. The aim of this study was to investigate the influence of length and diameter of intramedullary nail for subtrochanteric fracture models with Seinsheimer classification IIB using finite element analysis (FEA). Four types of intramedullary nail were considered: nail diameter 10mm and 12mm in long type, and nail diameter 10mm and 12mm in middle type. Subtrochanteric fracture finite element (FE) models with fracture type IIB that each nail was implanted were developed. A 1-mm-thick callus layer was set in the gap between bone fragments of the femur. As a result of FE analysis, the effectiveness of nail diameter increase was indicated from the viewpoint of bone union.</p>

    DOI: 10.1299/jsmemecj.2019.J02328P

    CiNii Article

    researchmap

  • Strength evaluation for sledge frame shape of Para Ice Hockey Reviewed

    ABE Yoshitaka, SASAGAWA Keisuke, ODA Masafumi, KAWAGOE Kenya

    The Proceedings of Mechanical Engineering Congress, Japan   2019 ( 0 )   J02330P   2019

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    <p>Para Ice Hockey is an adaptive form of ice hockey used for athletes who have a disability which could be from limb loss, spinal cord injury, or a condition such as cerebral palsy. Athletes use a special sled called a 'sledge' to play Para Ice Hockey. Because Para Ice Hockey is a very physical sport, a sledge needs strength and stiffness. Foreign-made sledge is heavy and bad handling for Japanese athletes so there is a necessity of their weight saving. Therefore, Mg alloy sledge was manufactured because of weight saving. However, there were some problems about strength and stiffness for Mg alloy sledge. The purpose of this study is to evaluate strength of frame shape for Mg alloy sledge using finite element (FE) analysis. Based on the drawing, CAD models of Mg alloy prototype sledge were created, and their FE models were constructed. From FEA result on frontal impact, several high stress values were found in the sledge frame.</p>

    DOI: 10.1299/jsmemecj.2019.J02330P

    CiNii Article

    researchmap

  • Prospects of Regional Revitalization Through Cooperative Education at Universities of Science and Technology Collaborating with SMEs in the Region

    KOURAKATA Itaru, NONAKA Satoshi, ODA Masafumi, WAKABAYASHI Etsuko, NAGAO Masanobu, TOSE Akira

    The Proceedings of the Tecnology and Society Conference   2019   G190416   2019

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmetsd.2019.g190416

    researchmap

  • Influence of iliofemoral ligament for proximal femoral fractures Reviewed

    SASAGAWA Keisuke, SAKURAI Kota, ODA Masafumi, SATO Akira, HARA Toshiaki

    The Proceedings of Mechanical Engineering Congress, Japan   2018 ( 0 )   J0270202   2018

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmemecj.2018.J0270202

    CiNii Article

    researchmap

  • Development of deep vein thrombosis prevention device for improving QOL of patients with long-lived bedding Reviewed

    YOKOYAMA Shohei, SASAGAWA Keisuke, ODA Masafumi, HIRUKAWA Hiroshi

    The Proceedings of Mechanical Engineering Congress, Japan   2018 ( 0 )   J0270404   2018

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmemecj.2018.J0270404

    CiNii Article

    researchmap

  • Biomechanical study on intramedullary nail fixation using small-diameter screw Reviewed

    SASAGAWA Keisuke, TANAKA Keita, ODA Masafumi, MAEHARA Takasi, SAKURAI Kota, HARA Toshiaki

    The Proceedings of Conference of Hokuriku-Shinetsu Branch   2018 ( 0 )   K024   2018

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmehs.2018.55.K024

    CiNii Article

    researchmap

  • Influence of intramedullary nail length for femoral subtrochanteric fracture model Reviewed

    SANO Takumi, SAKURAI Kouta, SASAGAWA Keisuke, ODA Masafumi, SHIOTA Naohumi

    The Proceedings of Mechanical Engineering Congress, Japan   2018 ( 0 )   J0270201   2018

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    <p>Intramedullary nail fixation is one of the useful treatments for subtrochanteric fracture. The intramedullary nail used is selected from two types, long type and short type. In many cases, long intramedullary nail is applied to treatment of subtrochanteric fractures. However, there is discussion on application of long intramedullary nail from the viewpoint of minimally invasive. A middle intramedullary nail, which has an intermediate length between long type and short type, was developed. It is essential to conduct biomechanical investigations of the intramedullary nail systems subjected to various loads. The aim of this study was to investigate the influence of length of intramedullary nail for subtrochanteric fracture models with Seinsheimer classification IIB. Three types of intramedullary nail were considered: long type, middle type, and short type. Subtrochanteric fracture finite element (FE) models, which included the femoral fracture of Seinsheimer classification IIB and the intramedullary nail system, were developed. A 1-mm-thick callus layer was set in the gap between bone fragments of the femur. As a result of FE analysis, the effectiveness of middle intramedullary nail was indicated from the viewpoint of bone union and invasiveness.</p>

    DOI: 10.1299/jsmemecj.2018.J0270201

    CiNii Article

    researchmap

  • Influence of length of intramedullary nail implant on bone fragment fixation for femoral trochanteric fracture Reviewed

    Keisuke SASAGAWA, Masafumi ODA, Naofumi SHIOTA

    39   167 - 173   2018

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    CiNii Article

    CiNii Books

    researchmap

  • 腸骨大体靱帯を考慮した大腿骨近位部の骨折リスク評価 Reviewed

    櫻井航太, 笹川圭右, 尾田雅文, 佐藤朗, 寺島正二郎, 原利昭

    39   175 - 180   2018

     More details

    Language:Japanese  

    researchmap

  • Fracture evaluation for femoral finite element model using iliofemoral ligament Reviewed

    SAKURAI Kota, SASAGAWA Keisuke, ODA Masafumi, SATOU Akira, TERASHIMA Shojiro, HARA Toshiaki

    The Proceedings of Conference of Hokuriku-Shinetsu Branch   2018 ( 0 )   K023   2018

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmehs.2018.55.K023

    CiNii Article

    researchmap

  • Influence of bone segments stability by intramedullary nail implants and small-diameter screw for femoral trochanter fracture Reviewed

    TANAKA Keita, SASAGAWA Keisuke, ODA Masafumi, MAEHARA Takashi, HARA Toshiaki, SAKURAI Kota

    The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2018 ( 0 )   1B08   2018

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmebio.2018.30.1B08

    CiNii Article

    researchmap

  • Influence of torsional loading on intramedullary nail fixation for femoral subtrochanteric fracuture. Reviewed

    38   47 - 54   2017.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    researchmap

  • Consideration of shape design of artificial hip joint using numerical analysis method Reviewed

    Japanese Journal of Clinical Biomechanics   38   259 - 265   2017.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    researchmap

  • Biomechanical analysis using an elastioc modulus gradient model of an artificial hip stemp Reviewed

    Japanese Journal of Clinical Biomechanics   38   267 - 274   2017.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    researchmap

  • Biomechanical Effects of Stretching Exercise on Site of Femoral Subtrochanteric Fracture Reviewed

    Aiko Noguchi, Keisuke Sasagawa, Masafumi Oda, Naofumi Shiota, Toru Sato, Toshiaki Hara

    The Society of Life Support Engineering   29 ( 3 )   100 - 105   2017.8

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    researchmap

  • Numerical analysis investigation on optimal shape design for femoral stem Reviewed

    SAKURAI Kota, SASAGAWA Keisuke, ODA Masafumi, HARA Toshiaki, NAKATA Katsuya, NOGUCHI Aiko

    The Proceedings of Conference of Hokuriku-Shinetsu Branch   2017 ( 0 )   D031   2017

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmehs.2017.54.D031

    CiNii Article

    researchmap

  • Biomechanical Investigation for Artificial hip stem with Gradient Function of Elastic Modulus Reviewed

    Tanaka Keita, Sasagawa Keisuke, Hara Toshiaki, Oda Masafumi, Sakurai Kota, Noguchi Aiko

    The Proceedings of Conference of Hokuriku-Shinetsu Branch   2017 ( 0 )   D032   2017

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmehs.2017.54.D032

    CiNii Article

    researchmap

  • Selection of intramedullary nail system for femoral subtrochanteric fractures Reviewed

    SASAGAWA Keisuke, ODA Masafumi, HARA Toshiaki, SHIOTA Naofumi

    The Proceedings of Mechanical Engineering Congress, Japan   2017 ( 0 )   J0250102   2017

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmemecj.2017.J0250102

    CiNii Article

    researchmap

  • Liver-targeted hydrodynamic gene therapy: Recent advances in the technique Reviewed

    Takeshi Yokoo, Kenya Kamimura, Hiroyuki Abe, Yuji Kobayashi, Tsutomu Kanefuji, Kohei Ogawa, Ryo Goto, Masafumi Oda, Takeshi Suda, Shuji Terai, Masafumi Oda

    WORLD JOURNAL OF GASTROENTEROLOGY   22 ( 40 )   8862 - 8868   2016.10

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:BAISHIDENG PUBLISHING GROUP INC  

    One of the major research focuses in the field of gene therapy is the development of clinically applicable, safe, and effective gene-delivery methods. Since the first case of human gene therapy was performed in 1990, a number of gene-delivery methods have been developed, evaluated for efficacy and safety, and modified for human application. To date, viral-vector-mediated deliveries have shown effective therapeutic results. However, the risk of lethal immune response and carcinogenesis have been reported, and it is still controversial to be applied as a standard therapeutic option. On the other hand, delivery methods for non-viral vector systems have been developed, extensively studied, and utilized in in vivo gene-transfer studies. Compared to viral-vector mediated gene transfer, nonviral systems have less risk of biological reactions. However, the lower gene-transfer efficiency was a critical hurdle for applying them to human gene therapy. Among a number of nonviral vector systems, our studies focus on hydrodynamic gene delivery to utilize physical force to deliver naked DNA into the cells in the living animals. This method achieves a high gene-transfer level by DNA solution injections into the tail vein of rodents, especially in the liver. With the development of genome editing methods, in vivo gene-transfer therapy using this method is currently the focus in this research field. This review explains the method principle, efficiency, safety, and procedural modifications to achieve a high level of reproducibility in large-animal models.

    DOI: 10.3748/wjg.v22.i40.8862

    Web of Science

    researchmap

  • 大腿骨転子下骨折の髄内釘固定術モデルにおける力学的検討 Reviewed

    野口 愛子, 笹川 圭右, 尾田 雅文, 塩田 直史, 佐藤 徹, 原 利昭

    臨床バイオメカニクス   37   173 - 179   2016.9

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:日本臨床バイオメカニクス学会  

    大腿骨転子下骨折に対する髄内釘法の適用では骨癒合のための整復位を保持することが難しく、固定力を高める目的でプレートが併用される。再手術に至った臨床例に基づいて構築した解析モデルに有限要素法によるシミュレーション解析を適用した。解析対象は60歳男性で、左大腿骨転子下骨折に髄内釘固定法を適用したが、偽関節およびインプラント破損に至り、新たな髄内釘とプレート固定併用により骨癒合が得られた。再術後CT画像を基に表面形状モデルを作成した。さらに3DCADソフトウェアを用いて大腿骨、髄内釘、プレート、スクリューのCADモデルを作成した。大腿骨転子下骨折治療における髄内釘インプラントの力学的状態と、プレート併用の影響を生体力学的に評価したところ、髄内釘固定治療におけるプレート追加の有用性が示された。骨折治療期間における繰り返し歩行荷重により、髄内釘インプラントの疲労破壊が生じる危険性も示唆された。

    researchmap

  • 高齢患者の多発骨盤骨折内固定における骨盤傾斜の影響 Reviewed

    野口 愛子, 勝山 恵子, 笹川 圭右, 尾田 雅文, 塩田 直史, 寺島 正二郎, 原 利昭

    臨床バイオメカニクス   36   157 - 164   2015.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:日本臨床バイオメカニクス学会  

    高齢患者の多発骨盤骨折内固定における骨盤傾斜の影響について検討した。骨盤の両側骨折を受傷し、内固定術により骨折部をプレートとスクリューで固定した75歳女性の臨床データを解析対象とした。骨盤患部の術後X線CT画像を基に、骨盤、プレートおよびスクリューそれぞれの三次元形状モデルを作成した。その結果、骨盤姿勢の後傾により、骨盤への負荷は増加傾向を示した。骨盤後傾姿勢では、インプラントへの負荷は増加傾向にあり、破損の危険性が高まることが示唆された。

    researchmap

  • 大腿骨ステム境界面におけるすべり量とステム長の関係 Reviewed

    櫻井 航太, 笹川 圭右, 勝山 恵子, 原 利昭, 寺島 正二郎, 尾田 雅文, 中田 活也

    臨床バイオメカニクス   36   171 - 180   2015.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:日本臨床バイオメカニクス学会  

    大腿骨ステム境界面におけるすべり量とステム長の関係について検討した。標準型セメントレスステムの人工股関節置換術(THA)を施行した10例(全例女性、平均67.0±6.3歳)を解析対象とした。THAの術前および術後にCT撮影を行った。術前および術後のCTスライス画像から、三次元画像再構築ソフトを用いて、大腿骨およびステムそれぞれの表面形状モデルを構築した。大腿骨の有限要素(FE)モデルには、術前CT画像から構築した大腿骨モデルとステムCADモデルをFEモデル構築に使用した。ステム長が50〜100%までの短縮化ならば初期固定性への影響は少なかった。ステム長の短縮化が30〜40%にかけては初期固定性が著しく低下した。

    researchmap

  • Quantitative single-cell motility analysis of platelet-rich plasma-treated endothelial cells in vitro Reviewed

    Tomoyuki Kawase, Takaaki Tanaka, Kazuhiro Okuda, Makoto Tsuchimochi, Masafumi Oda, Toshiaki Hara

    CYTOSKELETON   72 ( 5 )   246 - 255   2015.5

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:WILEY-BLACKWELL  

    Platelet-rich plasma (PRP) has been widely applied in regenerative therapy due to its high concentration of growth factors. Previous in vitro and in vivo studies have provided evidence supporting the angiogenic activity of PRP. To more directly demonstrate how PRP acts on endothelial cells, we examined the PRP-induced changes in the motility of human umbilical vein endothelial cells by examining the involvement of VEGF. Time-lapse quantitative imaging demonstrated that in the initial phase (approximate to 2 h) of treatment, PRP substantially stimulated cell migration in a wound-healing assay. However, this effect of PRP was not sustained at significant levels beyond the initial phase. The average net distance of cell migration at 10 h was 0.45 +/- 0.16 mm and 0.82 +/- 0.23 mm in control and PRP-stimulated cells, respectively. This effect was also demonstrated with recombinant human VEGF and was significantly attenuated by a neutralizing anti-VEGF antibody. Immunofluorescent examination of paxillin and actin fibers demonstrated that PRP concomitantly up-regulated focal adhesion and cytoskeletal formation. Western blotting analysis of phosphorylated VEGFR2 demonstrated that PRP mainly stimulated the phosphorylation of immature VEGFR2 in a dose- and time-dependent manner, an action that was completely blocked by the neutralizing antibody. Taken together, these data suggest that PRP acts directly on endothelial cells via the activation of VEGFR2 to transiently up-regulate their motility. Thus, the possibility that PRP desensitizes target endothelial cells for a relatively long period of time after short-term activation should be considered when the controlled release system of PRP components is designed. (c) 2015 Wiley Periodicals, Inc.

    DOI: 10.1002/cm.21221

    Web of Science

    researchmap

  • An atmospheric-pressure plasma-treated titanium surface potentially supports initial cell adhesion, growth, and differentiation of cultured human prenatal-derived osteoblastic cells Reviewed

    Tomoyuki Kawase, Takaaki Tanaka, Hiromi Minbu, Mana Kamiya, Masafumi Oda, Toshiaki Hara

    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS   102 ( 6 )   1289 - 1296   2014.8

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:WILEY-BLACKWELL  

    An atmospheric-pressure plasma (APP) treatment was recently reported to render titanium (Ti) surfaces more suitable for osteoblastic cell proliferation and osteogenesis. However, the mechanism of action remains to be clearly demonstrated. In this study, we focused on cell adhesion and examined the effects of the APP treatment on the initial responses of human prenatal-derived osteoblastic cells incubated on chemically polished commercially pure Ti (CP-cpTi) plates. In the medium containing 1% fetal bovine serum, the initial cell adhesion and the actin polymerization were evaluated by scanning electron microscopy and fluorescence microscopy. The expression of cell adhesion-related molecules and osteoblast markers at the messenger RNA level was assessed by real-time quantitative polymerase chain reaction. Although the cells on the APP-treated CP-cpTi surface developed fewer cytoskeletal actin fibers, they attached with higher affinity and consequently proliferated more actively (1.46-fold over control at 72 h). However, most of the cell adhesion molecule genes were significantly downregulated (from 40 to 85% of control) in the cells incubated on the APP-treated CP-cpTi surface at 24 h. Similarly, the osteoblast marker genes were significantly downregulated (from 49 to 63% of control) at 72 h. However, the osteoblast marker genes were drastically upregulated (from 197 to 296% of control) in these cells by dexamethasone and beta-glycerophosphate treatment. These findings suggest that the APP treatment improves the ability of the CP-cpTi surface to support osteoblastic proliferation by enhancing the initial cell adhesion and supports osteoblastic differentiation when immature osteoblasts begin the differentiation process. (C) 2014 Wiley Periodicals, Inc.

    DOI: 10.1002/jbm.b.33114

    Web of Science

    researchmap

  • Novel electric power-driven hydrodynamic injection system for gene delivery: Safety and efficacy of human factor IX delivery in rats Reviewed

    T. Yokoo, K. Kamimura, T. Suda, T. Kanefuji, M. Oda, G. Zhang, D. Liu, Y. Aoyagi

    Gene Therapy   20 ( 8 )   816 - 823   2013.8

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    The development of a safe and reproducible gene delivery system is an essential step toward the clinical application of the hydrodynamic gene delivery (HGD) method. For this purpose, we have developed a novel electric power-driven injection system called the HydroJector-EM, which can replicate various time-pressure curves preloaded into the computer program before injection. The assessment of the reproducibility and safety of gene delivery system in vitro and in vivo demonstrated the precise replication of intravascular time-pressure curves and the reproducibility of gene delivery efficiency. The highest level of luciferase expression (272 pg luciferase per mg of proteins) was achieved safely using the time-pressure curve, which reaches 30 mm Hg in 10 s among various curves tested. Using this curve, the sustained expression of a therapeutic level of human factor IX protein (&gt
    500 ng ml-1) was maintained for 2 months after the HGD of the pBS-HCRHP-FIXIA plasmid. Other than a transient increase in liver enzymes that recovered in a few days, no adverse events were seen in rats. These results confirm the effectiveness of the HydroJector-EM for reproducible gene delivery and demonstrate that long-term therapeutic gene expression can be achieved by automatic computer-controlled hydrodynamic injection that can be performed by anyone. © 2013 Macmillan Publishers Limited.

    DOI: 10.1038/gt.2013.2

    Scopus

    PubMed

    researchmap

  • Mechanical Evaluation for Fitting of NPPV Nasal Mask Reviewed

    Masafumi Oda, Keiichi Ninomiya, Toshiaki Hara

    Journal of Life Support Engineering   25 ( 4 )   124 - 129   2013

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    researchmap

  • Development of a capacitance type 6 axis force sensor Reviewed

    Masafumi ODA, Toshiaki HARA

    Life Support   23 ( 3 )   116 - 123   2011.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Society of Life Support Engineering  

    We have been developing a novel capacitance type force sensor that enables simultaneous measurement of a torque around the vertical axis as well as normal and two orthogonal shear forces on the skin surface. In our previous research, the prototype sensors were made and authenticated the potency. Prototype sensors are parallel plate type collocated a dielectric between two circuits. We have planned to use an approximated displacement-capacitance characteristic curve when we estimate an output force. Therefore, this paper reports about an ideal approximation of the curve and several applications, such as surgical robot and nursing-care system.

    DOI: 10.5136/lifesupport.23.116

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2012056612

  • Primary stability of tapered wedge-shaped cementless stems in patients with stvepipe canal and type c bone: Biomechanical estimation of primary micromotion Reviewed

    Katsuya NAKATA

    Journal of Japanese Society for Joint Diseases   29 ( 4 )   485 - 494   2010.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    DOI: 10.11551/jsjd.29.485

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2011124281

  • FE model construction for stress analysis on NPPV nasal mask Reviewed

    Keiichi NINOMIYA, Yuusuke YOSHIDA, Masafumi ODA

    24 ( 4 )   23 - 26   2009.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    CiNii Article

    researchmap

  • Computational dynamics of stress to act on at the time for NPPV Nasal Mask Reviewed

    Keiichi Ninomiya, Yuusuke Yoshida, Toshihiro Handa, Masafumi Oda, Toshiaki Hara

    The Society of Life Support Technology   21 ( 2 )   70 - 75   2009.6

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Society of Life Support Engineering  

    In late years, the patient load of chronic respiratory failure disease, such as a Obstructive Pulmonary Disease (COPD) or Sleep Apnea Syndrome (SAS) increaseschronic obstructive pulmonary disease (COPD) and sleep apnea syndrome (SAS), is increasing. For the patient, in whom such condition is comparatively serious, non-invasive positive pressure ventilation (NPPV) may be prescribed. Since this disposal method uses a nasal mask, a patient is treated non-invasively. Although, It is reported that skin obstacles arise, such as a pressure necrosis and compression gangrene, by the reason the mask pressed the face.<BR>Consequentially, it was created that the finite element model of the face portion based on a human body slice picture, and the stress which acts on the contact area of a nasal mask was calculated. And, It turned out that a nasal mask suitable for the form of an individual face is required, in order to reduce a skin obstacle.

    DOI: 10.5136/lifesupport.21.70

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2009283320

  • セメントレスステムの初期固定性に関する生体力学的定量評価 Reviewed

    中田活也, 山村在慶, 富士武史, 尾田雅文

    日本整形外科学会雑誌   83 ( 83 )   2   2009.2

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:日本整形外科学会  

    CiNii Article

    CiNii Books

    researchmap

  • A leg modeling system for designing artificial leg sockets Reviewed

    Masafumi Oda, Toshiaki Hara

    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C   75 ( 754 )   1725 - 1732   2009

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:Japan Society of Mechanical Engineers  

    When the relationship between the dimensions of the crural area and those of the artificial leg socket is poor, it may cause problems, such as pressure sores in the crural area. This study discusses the mechanical characteristics at artificial leg socket interfaces. A computer-aided design (CAD) model of the crural area was constructed from ultrasonic three-dimensional measurements of a crural model, and a personalized CAD model of the crural area was constructed using a free-form deformation technique. Next, a finite element (FE) model of an artificial leg socket constructed using a preliminary design was synthesized as the leg model. Then, the mechanical behavior at the interface between the crural model and artificial leg socket was investigated using finite element method (FEM) analysis. When the socket was adjusted to the leg, the Von Mises stress at the bottom of the socket decreased. This also had the effect of holding the socket stably.

    DOI: 10.1299/kikaic.75.1725

    Scopus

    researchmap

  • Stress analysis of accessories for NPPV nasal masks for FE personal model construction Reviewed

    Keiichi Ninomiya, Yusuke Yoshida, Masafumi Oda, Toshiaki Hara

    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C   75 ( 752 )   1026 - 1032   2009

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:Japan Society of Mechanical Engineers  

    The number of patients with chronic respiratory deficiency, such as Chronic Obstructive Pulmonary Disease (COPD) or Sleep Apnea Syndrome (SAS), is increasing. For patients with comparatively serious symptoms, the Non-invasive Positive Pressure Ventilation (NPPV) may be prescribed. However, pressure necrosis or anaclisis could affect treatment by occurring at the contact area of nasal mask. In response to this problem, the construction of a simulation environment can be applied. The system consists of leaser measurement technology and ultrasonic and the Free Form Deformation (FFD) technique. The shape of the face is measured by laser technology, while ultrasonic technology is used to measure he shape of soft tissue and bone. This personal simulation model was created based on these measurement results and the interpolation results using the FFD. A fundamental numerical analysis was performed, and Von Mises stress distribution was shown when the NPPV nasal mask made contact with the face. This also compared with the actually measured results. In conclusion, the finite element model made by the proposed system can reproduce the actual stress state. By using this system, the shape of a nasal mask suitable for each patient can be determined.

    DOI: 10.1299/kikaic.75.1026

    Scopus

    researchmap

  • 中越沖地震における地場産業の被害と復興状況(共著)

    尾田雅文, 小浦方格, 原利昭

    日本機械学会2008年度年次大会講演資料集(9)   2008.8

     More details

    Language:Japanese   Publishing type:Research paper (other academic)  

    researchmap

  • Dynamic Mechanical Characteristics of Thorax Structure Reviewed

    Hisashi Ohkawa, Yushi Suzuki, Yutaka Kaneta, Masafumi Oda, Toshiaki Hara

    Journal of Biomechanical Science and Engineering   3 ( 4 )   468 - 477   2008

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Thorax plays a crucial role in shielding internal organs from external loads. To establish a rational safety criterion for traffic accidents, it is important that we understand the mechanical behaviors of the thorax. We studied the response of thorax to impact experimentally. The purpose of this study is to understand the characterization of thoracic structure from measurement parameters by impact test. The specimen used was porcine thorax, the size of which was approximately equal to human thorax, after removing the internal organs. Using original test apparatus, the specimen was subjected to low energy impact and a sensitivity study was conducted to explore various parameters, including the response to the impact load, strain on each rib, and the acceleration and displacement in the thorax. Comparison of impact locations (front, back, and lateral) showed characteristic variations among the results. A frontal impact produced large acceleration and displacement. Therefore, it could be expected to stress the internal organs directly. In the case of an impact from behind, the impact response load was higher and the deformation of thorax was remarkably small. It appeared that the thoracic resists backward impact, and provides protection of internal organs. In lateral impact, the concentrated load tends to occur in the ribs, and the rib strain was high. Hence, the rib parts were prone to fracture, and the internal organs were subject to increased risk of secondary damages of the bone fracture due to bone sticking organs. In conjunction with the impact tests, static compressive tests were conducted. The deformation behavior of the thorax is grossly affected by the constraints of the binding of ligaments connecting bones. Therefore, this structure provides smooth elasticity by transforming the whole structure when a load is applied to the thoracic parts. This provided confirmation of the structural characteristics that were obvious in impact testing. This is the first time that attention has been paid to the thoracic structure and its deformation behavior has been investigated. The response of thoracic structures to external loads requires further research. © 2008, The Japan Society of Mechanical Engineers. All rights reserved.

    DOI: 10.1299/jbse.3.468

    Scopus

    researchmap

  • C06(4) 中越沖地震における地場産業の被害と復興状況(C06 能登半島および中越沖地震の被害調査報告,一般開放行事,市民フォーラム,21世紀地球環境革命の機械工学:人・マイクロナノ・エネルギー・環境)

    尾田 雅文, 小浦 方格, 原 利昭

    年次大会講演資料集   2008   23 - 24   2008

     More details

    Language:Japanese   Publisher:一般社団法人日本機械学会  

    DOI: 10.1299/jsmemecjsm.2008.9.0_23

    CiNii Article

    CiNii Books

    researchmap

  • 0921 Wavelet Transform for Evaluation of An Arthrodial Cartilage

    KOGURE Hidetomo, ODA Masafumi, HARA Toshiaki

    The proceedings of the JSME annual meeting   2007   143 - 144   2007

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    In this study, we developed the ultrasonic arthroscope, which can measure 3-dimesional position of the site of the disease, by using the 3-dimensional magnetic sensor. We measured the ultrasonic echo from articular cartilage upon which the enzyme acts. Then, wavelet transform was used to evaluate the articular cartilage. The result of this study showed that the echo amplitude is affected by enzyme processing time. And, the frequency domain from 12 to 17MHz disappeared.

    DOI: 10.1299/jsmemecjo.2007.5.0_143

    CiNii Article

    CiNii Books

    researchmap

  • 1051 Development of Surgical Sensor

    MORIJIRI Takeshi, ODA Masafumi, HARA Toshiaki, KOZAKAI Akifumi

    The proceedings of the JSME annual meeting   2007   63 - 64   2007

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    This paper is a study on the development of a haptic sensor system for robot surgery. The haptic sensor was manufactured by way of trial, which was consisted of rubber sensor and terete device. The terete device was allocated as hound's tooth check, for the purpose of estimation of normal load and traction load. Integral part of the tactile sensor system is the sensor itself i.e. the part of the system that transform the applied pressure/force in a change of resistance. The sensor output well describes the 3-dimensional distribution of force and will represent the subjective evaluations of surgeon.

    DOI: 10.1299/jsmemecjo.2007.6.0_63

    CiNii Article

    CiNii Books

    researchmap

  • The Fundamental Research on Optimum Design for NIPPV Nasal Mask

    NINOMIYA Keiichi, HANDA Toshihiro, ODA Masafumi, HARA Toshiaki

    Journal of Life Support Technology   18   109 - 109   2006

     More details

    Publisher:The Society of Life Support Engineering  

    DOI: 10.5136/lifesupport.18.Supplement_109

    CiNii Article

    researchmap

  • 531 Functional and Appropriate Design of the Prosthetic Socket Based on the Interfacial Pressure between Socket and Amputation Stump

    ONO Souhei, ODA Masafumi, TERASIMA Kazuhiro, HARA Toshiaki

    The proceedings of the JSME annual meeting   2006   117 - 118   2006

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    It is well known that there is a qualitative relationship between the loads exerted on a below-knee prosthesis and the stresses exerted on the amputee's stump. In this paper, the appropriate design system is developed to determine the highly favorable socket interface. This system demonstrated that, in the future studies, the use of CAD/CAM, ultrasound measurement technique and Free Form Deformation method with Visible Human Model for FEM analysis holds promise for highly endurability of below-knee prosthesis.

    DOI: 10.1299/jsmemecjo.2006.5.0_117

    CiNii Article

    CiNii Books

    researchmap

  • The Industry-University Cooperation and the Intellectual Property Enterprise at Post-institutionalization Invited

    ODA Masafumi

    Niigata medical journal   119 ( 8 )   450 - 453   2005.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    researchmap

  • Ultrasonic Measurement System using Wavelet Analysis for the Lower Leg Reviewed

    ASAI Kanako, HANAFUSA Akihiko, FUWA Teruhiko, ODA Masafumi, NAKAYAMA Tsuyoshi

    The Life Support Technorogy   17 ( 3 )   100 - 108   2005.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Society of Life Support Engineering  

    Checking the fit between a prosthetic socket and a residual limb is important for functional prostheses. Designing a prosthetic socket using a CAD system and checking the above mentioned fit by analyzing the deformation and stress under the weight of an amputee requires a three-dimensional model of the residual limb that includes not only the surface, but also the fat, muscle and bone. An ultrasonic measurement system, including a probe that three-dimensionally measures the external surface shape and the shapes of internal tissues simultaneously was developed. The system uses wavelet analysis to define the positions of the boundaries between each tissue. A cone-shaped aluminum test object was measured using the system, which was shown to be capable of measuring radius with an error of 0.6mm and slope with an error of 6%. In addition, the lower legs were measured, and the surface, muscles and bone boundaries were defined by wavelet analysis. The results of these measurements were compared to MRI cross sectional data, and the average error for the leg surface, muscles and tibia were 1.7mm, 2.4mm and 1.9mm, respectively, for boundaries that were determined correctly.

    DOI: 10.5136/lifesupport.17.100

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://search.jamas.or.jp/link/ui/2006091552

  • 1143 Ultrasonic screw hole detection of the intramedullary nail

    YAGI Takeo, KAWANA Takumi, UMENO Takatoshi, ODA Masafumi, HARA Toshiaki

    The proceedings of the JSME annual meeting   2005   127 - 128   2005

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    The clinical results for osteosynthesis using interlocking nailing generally have been good. However, the rate of radiation injury during the detection of nail hole has been noted to be seriously high, particularly in both of orthopedists and patients. We developed the ultrasonic technique to detect the distal nail hole and to relieve the radiation injury. The qualitative results were that technical experience and careful manipulation of probe are important factors in achieving a successful result.

    DOI: 10.1299/jsmemecjo.2005.5.0_127

    CiNii Article

    CiNii Books

    researchmap

  • Non-Contact Eye-Gazing Point Detection during Driving a Wheelchair Simulator Reviewed

    ODA Masafumi, ISOMURA Tsuneshi

    Transactions of the Japan Society of Mechanical Engineers. C   69 ( 685 )   2437 - 2444   2003.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    DOI: 10.1299/kikaic.69.2437

    researchmap

  • 逐次撃墜法を利用した車椅子操作時の非接触視点位置検出 Reviewed

    鉄谷聖和, 尾田雅文, 首藤由里子

    職業能力開発報文誌   15 ( 1 )   1 - 8   2003.4

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)   Publisher:職業能力開発総合大学校能力開発研究センター  

    CiNii Article

    CiNii Books

    researchmap

  • Direct Linear Transformation Technique for Non-Contact Eye-Gazing Point Detection : 2nd Report, Improving the Detecting Technique via Two Dimensional Multi Resolution Analysis Reviewed

    ODA Masafumi, ISOMURA Tsuneshi

    The Life Support Technorogy   14 ( 1 )   2 - 7   2002.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Society of Life Support Engineering  

    The Purpose of this study is to detect eye-gazing points during driving a wheelchair through the image sequence analysis of video frames. The performlances can be measured without restrictions of specific devices such as any accessories and sensors, which were put on a body. Images obtained with two video cameras allow the algorithm with two-dimensional multi resolution analysis through wavelet analysis to extract boundaries of right and left irises. Their three-dimensional positions and directions were estimated through direct linear transformation(DLT)technique. The eye-gazing point was evaluated through the relationship between the vertical vector of iris and line-of-sight. Consequently, Some preliminary results were presented to illustrate the detecting error of eye-gazing point.

    DOI: 10.5136/lifesupport.14.2

    CiNii Article

    CiNii Books

    researchmap

  • 2次元多重解像度解析を利用した非接触点位置検出法の検討 Reviewed

    尾田雅文, 鉄谷聖和, 首藤由里子

    職業能力開発報文誌   13 ( 2 )   17 - 24   2001.12

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)   Publisher:職業能力開発総合大学校能力開発研究センター  

    CiNii Article

    CiNii Books

    researchmap

  • 動的荷重条件下における人工股関節コンポーネントの歪み量評価 Reviewed

    帆足雅晃, 尾田雅文

    職業能力開発報文誌   13 ( 1 )   43 - 50   2001.12

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)   Publisher:職業能力開発総合大学校能力開発研究センター  

    CiNii Article

    CiNii Books

    researchmap

  • 2B22 Matching Pursuit Technique Estimation for Non-Contact Eye-Gazing Point Detection

    ODA Masafumi, ISOMURA Tsuneshi, SEKIGUCHI Yukio, HARA Toshiaki

    Proceedings of the JSME Bioengineering Conference and Seminar   2001   165 - 166   2001

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmebs.2001.12.0_165

    CiNii Article

    CiNii Books

    researchmap

  • Non-Contact Eye-Gazing Point Detection Technique via Two Dimensional Multi Resolution Analysis Reviewed

    Masafumi Oda, Nozomi Sanada, Yukio Sekiguchi, Tsuneshi Isomura, Toshiaki Hara

    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C   66 ( 650 )   3406 - 3412   2000

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    The purpose of this study is to detect eye-gazing points during driving a wheelchair through the image sequence analysis of video frames. The performances can be measured without restrictions of specific devices such as any accesories and sensors, which were put on a body. Images obtained with three video cameras allow the algorithm to extract four feature points on a face and irises. Their three-dimensional positions were estimated through direct linear transformation (DLT) technique with magnification of a facial image through multi resolution analysis. The direction of a face was estimated via three-dimensional positions of the former, and it defined the facial coordinate. On the other hand, the eye-gazing point was evaluated through three-dimensional positions of the latter. Consequently, Some preliminary results were presented to illustrate the difference in variations with the eye-gazing point between driving a wheelchair and walking. © 2000, The Japan Society of Mechanical Engineers. All rights reserved.

    DOI: 10.1299/kikaic.66.3406

    Scopus

    researchmap

  • Non-Contact Eye-Gazing Point Detection Technique via Two Dimensional Multi Resolution Analysis

    TETSUTANI Kiyokazu, SHUTO Yuriko, ODA Masafumi, ISOMURA Tsuneshi, SEKIGUCHI Yukio, HARA Toshiaki

    Proceedings of the JSME Bioengineering Conference and Seminar   2000   31 - 32   2000

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    DOI: 10.1299/jsmebs.2000.11.0_31

    CiNii Article

    CiNii Books

    researchmap

  • Direct Linear Transformation Technique for Non-Contact Eye-Gazing Point Detection : 2nd Report, Improving the Detecting Technique via Two Dimensional Multi Resolution Analysis Reviewed

    ODA Masafumi, SANADA Nozomi

    The Life Support Technorogy   11 ( 3 )   80 - 85   1999.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Society of Life Support Engineering  

    The purpose of this study is to detect eye-gazing points during driving a wheelchair through the image sequence analysis of video frames.The performances can be measured without restrictions of specific devices such as any accessories and sensors,which were put on a body.Images obtained with three video cameras allow the algorithm to extract four feature points on a face and irises.Their three-dimensional positions were estimated through direct linear transformation(DLT)technique with magnification of a facial image through wavelet analysis.The direction of a face was estimated via three-dimensional positions the former,and it defined the facial coordinate.On the other hand,the eye-gazing point was evaluated through three-dimensional positions of the latter.Consequently,Some preliminary results were presented to illustrate the difference in variations with the eye-gazing point between driving a wheelchair and walking .

    DOI: 10.5136/lifesupport.11.80

    CiNii Article

    CiNii Books

    researchmap

  • Ultrasonic technique for contact mechanism estimation of an artificial hip joint Reviewed

    Masafumi Oda, Tasuku Kanomata, Toshiaki Hara

    JSME International Journal, Series C: Mechanical Systems, Machine Elements and Manufacturing   42 ( 3 )   560 - 567   1999

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Japan Society of Mechanical Engineers  

    Ultrasonic techniques were developed to study the characteristics for contact mechanics of an artificial hip joint. Total Hip Replacement model was used to determine contact pressure distribution on an artificial aceptabular cup subjected to compressive load ranged from 196 N to 588 N in four femur positions. The contact pressure was found to be non-uniform and reaches more than 6 MPa. It was shown that the tendency of the pressure distribution is in agreement with that obtained by the computer simulation. Some preliminary results were also presented to illustrate the effect of the direction and the magnitude of the load applied to a femoral head on the contact pressure distribution on the aceptabular cup and to evaluate the contact mechanism of the artificial hip joint.

    DOI: 10.1299/jsmec.42.560

    Scopus

    researchmap

  • Ultrasonic Technique for Contact Mechanism Estimation of an Artificial Hip Joint Reviewed

    ODA Masafumi, HARA Toshiaki

    Transactions of the Japan Society of Mechanical Engineers. A   64 ( 624 )   2093 - 2099   1998.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Japan Society of Mechanical Engineers  

    An ultrasonic techniques was developed to study the characteristics for contact mechanics of an artificial hip joint. Total Hip Replacement model was used to determine contact pressure distribution on an artificial aceptabular cup subjected to compressive load ranged from 196 N to 588 N in four femur positions. The contact pressure was found to be nonuniform and less than 6 MPa. It was shown that the tendency of the pressure distribution is in agreement with that obtained by the computer simulation. Some preliminary results were also presented to illustrate the effect of the direction and the magnitude of the load applied to a stem on the contact pressure distribution on the aceptabular cup and to evaluate the contact mechanism of the artificial hip joint.

    DOI: 10.1299/kikaia.64.2093

    CiNii Article

    CiNii Books

    researchmap

    Other Link: https://jlc.jst.go.jp/DN/JALC/00085215993?from=CiNii

  • Ultrasonic Technique for Contact Mechanism Estimation of an Artifical Hip Joint Reviewed

    ODA Masafumi

    The Life Support Technorogy   10 ( 3 )   111 - 118   1998.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Society of Life Support Engineering  

    An ultrasonic technique was developed to study the characteristics for contact mechanics of an artificial hip joint. Total Hip Replacement model was used to determine contact pressure distribution on an artificial aceptabular cup subjected to compressive load ranged from196N to 588N in four femur positions. The contact pressure was found to be nonuniform and less than 6MPa. It was shown that the tendency of the pressure distribution is in agreement with that obtained by the computer simulation.Some preliminary results were also presented to illustrate the effect of the direction and the magnitude of the load applied to a stem on the contact pressure distribution on the aceptabular cup and to evaluate the contact mechanism of the artificial hip joint.

    DOI: 10.5136/lifesupport.10.111

    CiNii Article

    CiNii Books

    researchmap

  • 超音波法による摺動時の摩擦力評価 Reviewed

    尾田 雅文

    職業能力開発報文誌   9 ( 2 )   17 - 24   1997.10

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)  

    researchmap

  • 鋼-セラミクス摺動時の摺動初期における摩擦応力解析

    尾田雅文

    新潟職業能力開発短期大学校紀要   3   8 - 13   1997.3

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)  

    researchmap

  • Adhesion Evaluation of TiN Film by Acoustic Emission Technique Reviewed

    ODA Masafumi, HARA Toshiaki

    Transactions of the Japan Society of Mechanical Engineers. A   62 ( 595 )   865 - 871   1996.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:The Japan Society of Mechanical Engineers  

    An acoustic emission (AE) technique was developed to study the adhesional characteristics of TiN thin film deposited on SKD and SKH steel using plasma CVD technique. Pin-on-disk type wear testing machine with acoustic emission sensor was used to measure the relationship between the AE count rates monitored through the pin and the wear rate of the steel materials deposited by the thin film and to investigate the adhesional strength of the film. In addition, the applicability of the Root Mean Square (RMS) value derived from the AE signal to the evaluation of the wear and frictional properties of the steel was discussed, The experimental results showed that the relationship between the wear rate and the RMS value was significantly dependent upon the mechanical properties of the pin with a deposition of the film. The frictional coefficient derived from the interface between the pin and the disk increased slightly with an increase in the amount of indentational load applied to the pin. It may also mentioned that the present results demonstrate sufficient promise of the ability of the AE technique to be applied to the evaluation of the thin film deposited on metallic materials.

    DOI: 10.1299/kikaia.62.865

    CiNii Article

    CiNii Books

    researchmap

    Other Link: https://jlc.jst.go.jp/DN/JALC/00038913440?from=CiNii

  • Contact Pressure Measurement utilizing Time-Frequency Analysis of Ultrasonic Reflected Wave at the Rubber Surface in Sliding Contact Reviewed

    ODA Masafumi, HARA Toshiaki

    Transactions of the Japan Society of Mechanical Engineers. A   62 ( 598 )   1425 - 1431   1996.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    DOI: 10.1299/kikaia.62.1425

    CiNii Article

    researchmap

  • A Characteristic on Abrasion Pattern on a Sliding Surface of Rubber under Stick-Slip Motion Reviewed

    ODA Masafumi, HARA Toshiaki

    Transactions of the Japan Society of Mechanical Engineers. A   61 ( 587 )   1663 - 1668   1995.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    DOI: 10.1299/kikaia.61.1663

    CiNii Article

    researchmap

  • Tribological Evaluation of Boriding Metal by Acoustic Emission Technique Reviewed

    ODA Masafumi, HARA Toshiaki

    Transactions of the Japan Society of Mechanical Engineers. C   61 ( 591 )   4450 - 4456   1995.12

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)  

    DOI: 10.1299/kikaic.61.4450

    researchmap

  • ゴム摺動時の接触圧力挙動

    尾田雅文

    新潟職業能力開発短期大学校紀要   1   1 - 7   1995.3

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)  

    researchmap

  • 新素材等の耐摩耗特性に関する研究(硼化処理鋼の耐摩耗特性及びAE信号測定による危険予知)

    尾田雅文, 高野格, 田中亙, 桂沢豊

    新潟県工業技術研究報告書   20   29 - 34   1991.3

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)  

    researchmap

  • 新素材等の耐摩耗特性に関する研究(セラミクス及び各種表面処理材の耐摩耗特性)

    尾田雅文, 高野格, 田中亙, 三村和弘

    新潟県工業技術研究報告書   19   27 - 32   1990.3

     More details

    Language:Japanese   Publishing type:Research paper (bulletin of university, research institution)  

    researchmap

▶ display all

Books

  • 3D×テーラーメイド医療 実践股関節手術

    中田活也, 尾田雅文( Role: Joint editor)

    金芳堂  2016.11  ( ISBN:9784765316934

     More details

    Language:Japanese Book type:Scholarly book

    researchmap

  • 福祉工学(共著)

    依田光正, 塩田泰仁, 寺師良輝, 花房昭彦, 向後礼子, 垣本映, 河合俊宏, 松田康広, 依田麻子, 磯村恒, 根武谷吾, 船久保昭夫, 尾田雅文( Role: Joint author)

    理工図書  2011.2 

     More details

    Language:Japanese Book type:Textbook, survey, introduction

    researchmap

  • 地域中小企業の高学歴インターンシップ受け入れ環境整備と新規産学連携ルート開拓

    坪川紀夫, 尾田雅文, 後藤隆夫, 中津普門, 長濱勝介( Role: Joint author)

    国立大学法人 新潟大学  2009.3 

     More details

    Language:Japanese Book type:Report

    researchmap

  • 能登半島および中越沖地震による地場産業等の被害とその復興に関する臨時調査分科会成果報告書

    尾田十八, 尾田雅文( Role: Joint author ,  第2調査班中越沖地震担当)

    日本機械学会  2009.3 

     More details

    Language:Japanese Book type:Report

    researchmap

  • 大学特許の活用の成果例分析の研究報告書

    谷川紘太郎, 尾田雅文( Role: Joint author)

    国立大学法人 長崎大学  2008.3 

     More details

    Language:Japanese Book type:Report

    researchmap

  • 「国際的な産学官連携を進める上で問題となるアジア各国(中国・韓国)と日本との特許制度における相違点に関する調査研究」に関する調査報告書

    長谷川彰, 尾田雅文( Role: Edit)

    新潟県大学連合知的財産本部  2007.3 

     More details

    Language:Japanese Book type:Report

    researchmap

▶ display all

MISC

  • Influence of bending and torsion load timing on trochanteric hip fractures.

    阿部佳峻, 笹川圭右, 尾田雅文, 佐藤朗

    臨床バイオメカニクス(Web)   44   2023

  • Dynamic finite element analysis of trochanteric fracture of femur considering of bone fragmentation

    佐藤朗, 阿部佳峻, 笹川圭右, 尾田雅文

    骨折(Web)   45 ( 3 )   2023

  • Analytical study of influence of bending and torsion on femoral trochanteric fracture patterns.

    阿部佳峻, 笹川圭右, 尾田雅文, 佐藤朗

    臨床バイオメカニクス(Web)   43   2022

  • Bone fracture analysis for calcaneus

    阿部佳峻, 笹川圭右, 尾田雅文, 塩田直史

    日本機械学会年次大会講演論文集(CD-ROM)   2022   2022

  • Mechanistic analysis of femoral trochanteric fracture considering bone fragmentation.

    阿部佳峻, 笹川圭右, 尾田雅文, 佐藤朗, 原利昭

    臨床バイオメカニクス   42   2021

  • Shape design for weight reduction of sledge used on para ice hockey

    阿部佳峻, 笹川圭右, 尾田雅文, 川越健矢

    日本機械学会北陸信越支部総会・講演会講演論文集(CD-ROM)   57th   2020

  • Fracture mechanical considerlation of irreducible penetrated trochanteric fracture of femur

    佐藤朗, 湊泉, 野崎あさみ, 原利昭, 笹川圭右, 尾田雅文

    整形・災害外科   63 ( 12 )   2020

  • 大腿骨転子下骨折の骨折部固定性に及ぼす髄内釘長さの生体力学的評価

    笹川 圭右, 佐野 匠, 尾田 雅文, 塩田 直史, 佐藤 徹

    臨床バイオメカニクス   40   45 - 52   2019.10

     More details

    Language:Japanese   Publisher:日本臨床バイオメカニクス学会  

    転子下骨折の治療において、適切な髄内釘インプラントの長さを選択するためには、骨折治療への影響を力学的・臨床的の双方から検討を行う必要がある。本研究では、転子下骨折の骨折部固定性について、髄内釘インプラントの長さによる影響を有限要素(FE)解析によって比較検討することを目的とした。転子下骨折の一分類手法であるSeinsheimer分類のType II A、II BおよびII Cに基づいた3種類の骨折モデルを対象とし、髄内釘が埋植された転子下骨折FEモデルをそれぞれ構築した。髄内釘インプラントには異なる長さをもつロング型、ミドル型、ショート型の3種類を使用した。解析の結果、仮骨部に生じる圧縮応力領域が広範囲であることによる骨髄合促進や、応力遮蔽の抑制への期待、さらに侵襲性の観点からミドル型の髄内釘インプラントの有効性が示唆された。(著者抄録)

    researchmap

  • Slot‐scanning 3D X‐ray imager(EOS)による脊椎アライメントの3次元評価に関する精度評価

    笹川圭右, 岡本昌士, 長谷川和宏, 尾田雅文, 原利昭, 初鹿野駿

    Journal of Spine Research   8 ( 3 )   618 - 618   2017.3

     More details

    Language:Japanese  

    J-GLOBAL

    researchmap

  • 非定型大腿骨転子下骨折の治療成績―臨床成績と有限要素解析による力学的検討―

    塩田直史, 佐藤徹, 黒田崇之, 金澤智子, 尾田雅文, 笹川圭右, 野口愛子, 原利昭

    骨折   38 ( Suppl. )   S428 - S428   2016.7

     More details

    Language:Japanese  

    J-GLOBAL

    researchmap

  • 909 Comparison between EOS system and CT model in Three-Dimensional Spinal Alignment Evaluation

    ANZAWA Takuma, SASAGAWA Keisuke, HASEGAWA Kazuhiro, OKAMOTO Masashi, ODA Masafumi, HARA Toshiaki

    2016 ( 53 )   "909 - 1"-"909-4"   2016.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    The sterEOS X-ray machine is capable of a simultaneous capture of biplanar X-ray images by slot scanning of the whole body in physiological load-bearing position. The simultaneous capture of spatially calibrated anteroposterior and lateral images provides a three-dimensional (3D) surface modelling of the skeletal system using sterEOS 3D software. The relevant clinical parameters such as spinal and pelvic parameters are supposed to be measured. The aim of this study is to evaluate an accuracy of EOS measurement on spinal alignment. A phantom for X-ray imaging was used for CT scanning and sterEOS X-ray imaging. 3D surface models of a phantom were reconstructed from its CT images. The same clinical parameters measured from CT-derived 3D surface models and sterEOS 3D software were compared.

    CiNii Article

    CiNii Books

    researchmap

  • Functional Design for Orthopaedic Instrument

    ( 20 )   223 - 233   2016.3

     More details

    Language:Japanese  

    Length of the femoral stem is reduced to prevent loosening and to preserve bone stock for potential revision surgery. However, the influence of the stem shortening on primary stability and weight bearing is not investigated enough from a dynamic viewpoint. In the present paper, we report primary stabilities of five femoral stems with different length based on clinical Total Hip Arthroplasty (THA) data. The length was based on standard type of tapered wedge-shaped cementless stem, defined as 100% of the stem length. Furthermore, comparison of femoral stems having 75%, 50%, 40% and 30% of the stem length was made. The subject was ten female patients operated for THA. Finite Element model implanted with five lengths of the femoral stem was loaded by forces representing two physiological activities: walking and stair climbing. In conclusion, when the stem length became less than 40%, the primary stability of the stem decreased. These results, suggested that excessive stem shortening had an influence on the weight bearing.

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://id.nii.ac.jp/1714/00000240/

  • 1F15 Accuracy Verification on Three-Dimensional Evaluation of Spinal Alignment Using sterEOS

    ANZAWA Takuma, SASAGAWA Keisuke, HASEGAWA Kazuhiro, OKAMOTO Masashi, ODA Masafumi, KATSUYAMA Keiko, HARA Toshiaki

    2016 ( 28 )   "1F15 - 1"-"1F15-4"   2016.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    The sterEOS X-ray machine is capable of a simultaneous capture of biplanar X-ray images by slot scanning of the whole body in physiological load-bearing position. The simultaneous capture of spatially calibrated anteroposterior and lateral images provides a three-dimensional (3D) surface modelling of the skeletal system using sterEOS 3D software. The relevant clinical parameter such as spinal and vertebral parameters are supposed to be measured. The aim of this study is to evaluate an accuracy of EOS measurement of spinal alignment. A phantom for X-ray imaging was used for CT scanning and sterEOS X-ray imaging. 3D surface models of a phantom were reconstructed from its CT images. The same clinical parameters measured from CT-derived 3D surface models and sterEOS 3D software were compared.

    CiNii Article

    CiNii Books

    researchmap

  • 2C11 Proposal of a semi-order type silicone rubber cushion for pressure ulcer prevention

    TERASHIMA Shojiro G, ODA Masafumi, KATSUYAMA Keiko, SASAGAWA Keisuke, HARA Toshiaki, Tanaka Masaki, Ikeno Masayuki

    2016 ( 28 )   "2C11 - 1"-"2C11-5"   2016.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    For the wheelchair users, pressure distribution cushion is essential to prevent pressure ulcer. On the other hand, cushion needs to have the function of keeping sitting posture, especially for spinal cord injury, cervical cord injury or elderly persons. For this issue, we propose the cushion with a layered structure of the silicon rubber block cube. This contrivance provides both of the scattering pressure and maintaining sitting posture. The block cubes are constructed by wrapping soft silicone rubber up in the hard silicone rubber. And because of the layered structure, the cushion can be custom-made to fit the shape of the individual users' hip. In this paper, we have tried to develop custom-made silicone rubber cushion and we compared the pressure distributions when users use the silicon rubber cushion and same shape urethane cushion. Both of silicon rubber and urethane cushion have excellent enough performances of the pressure prevention. The pressure distributions by using the silicone rubber cushion haven't showed big difference according to the wheelchair tilting. These results suggest that the silicone rubber cushion has the good performance of keeping users' body posture on their wheelchair.

    CiNii Article

    CiNii Books

    researchmap

  • PS5-6 FINITE ELEMENT ANALYSIS OF MULTIPLE PELVIC FRACTURES WITH PLATE FIXATION(PS5: Poster Short Presentation V,Poster Session)

    Noguchi Aiko, Katsuyama Keiko, Sasagawa Keisuke, Oda Masafumi, Shiota Naofumi, Terashima Shojiro George, Hara Toshiaki

    Proceedings of the ... Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics   2015 ( 8 )   304 - 304   2015.9

     More details

    Language:English   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • GS2-9 FINITE ELEMENT ANALYSIS OF PRIMARY STABILITY ON SHORT STEM HIP IMPLANT(GS2: Orthopaedic Biomechanics II)

    Sasagawa Keisuke, Sakurai Kota, Oda Masafumi, Katsuyama Keiko, Hara Toshiaki, Nakata Katsuya, Terashima Shojiro George

    Proceedings of the ... Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics   2015 ( 8 )   152 - 152   2015.9

     More details

    Language:English   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • テーパーウェッジ型ステムにおけるステム長と初期固定性に関する生体力学的解析

    中田 活也, 北田 誠, 田村 理, 大脇 肇, 冨士 武史, 尾田 雅文, 笹川 圭右, 勝山 恵子, 原 利昭

    日本整形外科学会雑誌   89 ( 2 )   S176 - S176   2015.3

     More details

    Language:Japanese   Publisher:(公社)日本整形外科学会  

    J-GLOBAL

    researchmap

  • 1A35 Effect for the primary stability on shape change of the artificial hip stem

    SAKURAI Kota, SASAGAWA Keisuke, KATSUYAMA Keiko, ODA Masafumi, NAKATA Katsuya, TERASIMA Shojiro, HARA Toshiaki

    2015 ( 27 )   35 - 36   2015.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 1E24 Material Properties Estimation for Intervertebral Disc Damage Using Finite Element Method

    Sasagawa Keisuke, Oda Masafumi, Katsuyama Keiko, Hasegawa Kazuhiro, Hara Toshiaki, Terashima Shojiro

    2015 ( 27 )   193 - 194   2015.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 2E11 Mechanical Analysis of Multiple Pelvic Fracture with Plate Fixation in Consideration of Posture of Elderly Patient

    NOGUCHI Aiko, KATSUYAMA Keiko, SASAGAWA Keisuke, ODA Masafumi, SIOTA Naofumi, TERASHIMA Shojiro, HARA Toshiaki

    2015 ( 27 )   477 - 478   2015.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • J0210305 Finite Element Analysis for Functional Strength of Spine Fixation Device

    SASAGAWA Keisuke, ODA Masafumi, KATSUYAMA Keiko, HASEGAWA Kazuhiro, HARA Toshiaki, TERASHIMA Shojiro

    Mechanical Engineering Congress, Japan   2014   "J0210305 - 1"-"J0210305-4"   2014.9

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    A representative surgery of scoliosis is the posterior correction and fusion using spinal fixation device. The aim of this study is to evaluate usability of minor diameter rod for spinal fixation device. Lumbar finite element (FE) models from the Ll vertebra to the L5 vertebra with segmental pedicle screw fixation were reconstructed. Four rod diameter in spinal fixation device were used. Two types of loading conditions were evaluated, including flexion and lateral bending under preload with 200N of axial compressive force on the superior surface of the Ll vertebra. The inferior end surface of the L5 vertebra was assumed to be fully constrained. As a result, it was found that von Mises stresses in the minor rod diameter of spinal fixation device were lower than the fatigue strength of titanium alloy.

    CiNii Article

    CiNii Books

    researchmap

  • 112 Mechanical Analysis of Multiple Pelvic Fracture with Plate Fixation

    NOGUCHI Aiko, KATHUYAMA Keiko, SASAGAWA Keisuke, ODA Masafumi, SIOTA Naofumi, TERASHIMA Shouzirou, HARA Toshiaki

    2014 ( 51 )   "112 - 1"-"112-2"   2014.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 114 Operation test of the improved intraoperative measurement system for evaluation of lumbar segmental instability

    Kobayashi Fuminori, Maekawa Yuki, Terashima Shojiro, Hasegawa Kazuhiro, Kitahara Ko, Sasagawa Keisuke, Katsuyama Keiko, Oda Masafumi

    2014 ( 51 )   "114 - 1"-"114-2"   2014.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 115 Relationship between stem lengths and primary stability with micromotion of the femoral stem

    SAKURAI Kota, ANZAWA Takuma, SASAGAWA Keisuke, KATSUYAMA Keiko, ODA Masafumi, TERASIMA Shojiro, HARA Toshiaki, NAKATA Katsuya

    2014 ( 51 )   "115 - 1"-"115-2"   2014.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • テーパーウェッジ型ステムの初期固定性 スタンダードとショートタイプの比較

    中田 活也, 北田 誠, 秋山 慶輔, 大脇 肇, 尾田 雅文, 笹川 圭右, 勝山 恵子, 原 利昭

    日本整形外科学会雑誌   88 ( 3 )   S959 - S959   2014.3

     More details

    Language:Japanese   Publisher:(公社)日本整形外科学会  

    researchmap

  • 大腿骨ステム埋植部のマイクロモーションによる初期固定性とステム長の関係

    櫻井航太, 安澤拓真, 笹川圭右, 勝山恵子, 尾田雅文, 寺島正二郎, 原利昭, 中田活也

    日本機械学会北陸信越支部総会・講演会講演論文集(CD-ROM)   51st   2014

  • 改良型術中脊椎不安定性評価システムの試用

    小林史法, 前川勇樹, 寺島正二郎, 長谷川和弘, 北原恒, 笹川圭右, 勝山恵子, 尾田雅文

    日本機械学会北陸信越支部総会・講演会講演論文集(CD-ROM)   51st   2014

  • B216 Finite Element Analysis of Pelvic Fracture with Plate Fixation

    NOGUCHI Aiko, KATHUYAMA Keiko, SASAGAWA Keisuke, ODA Masafumi, SIOTA Naofumi, TERASHIMA Shouzirou, HARA Toshiaki

    Proceedings of the ... JSME Conference on Frontiers in Bioengineering   2013 ( 24 )   135 - 136   2013.10

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • B211 Improvement of the intraoperative measurement system for evaluation of lumbar segmental instability

    Kobayashi Fuminori, Maekawa Yuki, Terashima Shojiro, Hasegawa Kazuhiro, Kitahara Ko, Sasagawa Keisuke, Katsuyama Keiko, Oda Masafumi

    Proceedings of the ... JSME Conference on Frontiers in Bioengineering   2013 ( 24 )   125 - 126   2013.10

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • B210 Comparison of micromotion at the bone-implant interface of femoral stem

    SAKURAI Kota, ANZAWA Takuma, SASAGAWA Keisuke, KATSUYAMA Keiko, ODA Masafumi, TERASIMA Shojiro, HARA Toshiaki, NAKATA Katsuya

    Proceedings of the ... JSME Conference on Frontiers in Bioengineering   2013 ( 24 )   123 - 124   2013.10

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • J024053 Primary Stability Evaluation for Short Stem Hip Implant

    SASAGAWA Keisuke, ODA Masafiimi, KATSUYAMA Keiko, NAKATA Katsuya, HARA Toshiaki, TERASHIMA Shojiro

    Mechanical Engineering Congress, Japan   2013   "J024053 - 1"-"J024053-5"   2013.9

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    In total hip arthroplasty, the cementless femoral stem implants have been used. Initial stability of a cementless femoral stem depends on the mechanical interlocking of the stem by press-fitting into the femoral canal. The movement of the stem relative to the femur occurs when the implant is subjected to a load. The inducible movements at the implantbone interface is defined as micromotion. It has been suggested that the use of a short stemmed implant could conserve proximal femur and reduce the extent of proximal stress shielding. However, it has little reports on the primary stability of the short stemmed implant. The aim of this study is to examine the primary stability of the short stemmed implants using the finite element analysis. The finite element model of the short stemmed implant inserted into the femur with the same alignment as the standard stemmed implant was created to compare the primary stability between the short stemmed implant and the standard stemmed implant. The maximum load during walking was applied to the stem. The micromotion was examined at both the short stemmed implant and the standard stemmed implant.

    CiNii Article

    CiNii Books

    researchmap

  • 0315 Liver model for hydrodynamic gene delivery

    LI Shengguo, ODA Masafumi, TANABE Yuji, YOKOO Ken, KAMIMURA Kenya, SUDA Takeshi

    2013 ( 50 )   31501 - 31502   2013.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 0312 Finite Element Analysis on Short Stem Hip Implant

    SASAGAWA Keisuke, ODA Masafumi, KATSUYAMA Keiko, NAKATA Katsuya, HARA Toshiaki, TERASHIMA Shojiro

    2013 ( 50 )   31201 - 31202   2013.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • ショート型人工股関節ステムの有限要素解析

    笹川圭右, 尾田雅文, 勝山恵子, 中田活也, 原利昭, 寺島正二郎

    日本機械学会北陸信越支部総会・講演会講演論文集(CD-ROM)   50th   2013

  • B215 Elicitation technique for controlled parameter of Computer-assisted hydrodynamic gene delivery

    Li Shengguo, Ootsuka Noriaki, Oda Masafumi, Tanabe Yuji, Yokoo Ken, Kamimura Kenya, Suda Takeshi

    Proceedings of the ... JSME Conference on Frontiers in Bioengineering   2012 ( 23 )   155 - 156   2012.10

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 1214 Elicitation technique for controlled parameter of Computer-assisted hydrodynamic gene delivery

    OTSUKA Noriaki, ODA Masafumi, HARA Toshiaki, SUDA Takeshi, KAMIMURA Kenya, YOKOO Takeshi

    2012 ( 49 )   121401 - 121402   2012.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 1210 Stability Evaluation of the Silicone Mattress for Pressure Ulcer Prevention

    MUKAE Hirohito, ODA Masafumi, HARA Toshiaki, TANAKA Masaki, IKENO Masayuki

    2012 ( 49 )   121001 - 121002   2012.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 1008 Psychophysical Evaluation of Postural Change for prevention of decubitus

    MUKAE Hirohito, ODA Masafumi, HARA Toshiaki, TANAKA Masayoshi

    2011 ( 48 )   327 - 328   2011.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 9D-12 The high lateral resolution imaging method using by ultrasonic technique for 3D modeling

    TAKEDA Tomomi, ODA Masafumi, HARA Toshiaki, SUDA Takeshi, KAMIMURA Kenya

    2010 ( 23 )   375 - 376   2011.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 716 Gene therapy equipment made on an experimental basis of hepatic disease

    IMAI Tsuyoshi, ODA Masafumi, HARA Toshiaki, SUDA Takeshi

    2010 ( 47 )   263 - 264   2010.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 1006 A study on noise elimination method considering temporal axis in ultrasonic images

    TAKEDA Tomomi, ODA Masafumi, HARA Toshiaki

    2009 ( 22 )   170 - 170   2010.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 0726 Detection of dynamic information using hybrid haptic sensor

    OHTA Masahiro, MUKAE Hirohito, ODA Masafumi, HARA Toshiaki, KOZAKAI Akifumi

    2009 ( 22 )   298 - 298   2010.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • B113 Mechanical evaluation for fitting of NPPv nasal mask

    YOSHIDA Yusuke, NINOMIYA Keiichi, ODA Masafumi, HARA Toshiaki

    Proceedings of the ... JSME Conference on Frontiers in Bioengineering   2009 ( 20 )   53 - 54   2009.11

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 超音波計測に基づく人体パーソナルモデリングと機器設計

    尾田雅文

    ケミカルエンジニアリング   54 ( 5 )   329 - 334   2009.5

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (trade magazine, newspaper, online media)   Publisher:化学工業社  

    CiNii Article

    CiNii Books

    researchmap

  • 1222 Fundamental study on wavelet-based improvement of ultrasonic images

    TAKEDA Tomomi, ODA Masafumi, HARA Toshiaki, TETSUTANI Kiyokazu

    2009 ( 46 )   487 - 488   2009.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 622 Impact Response Analysis of Thorax Structure

    OHKAWA Hisashi, SUZUKI Yusi, KANETA Yutaku, ODA Masafumi, HARA Toshiaki

    2008 ( 21 )   275 - 276   2009.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • Ultrasonic Estimation for Order-Made System of Medical Devices and Welfare Equipments

    Masafumi Oda

    JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS   54 ( 10 )   683 - 688   2009

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (scientific journal)   Publisher:JAPAN SOC TRIBOLOGISTS  

    Web of Science

    researchmap

  • 432 Force evaluation for scalpel operation by using electrical capacitance multi-axis force sensor

    Ota Masahiro, ODA Masafumi, HARA Toshiaki, KOZAKAI Akifumi

    2008 ( 21 )   397 - 398   2009

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • A323 Fundamental study on the adaptive design system for NPPV nasal mask

    YOSHIDA Yusuke, NINOMIYA Keiichi, ODA Masafumi, HARA Toshiaki

    Proceedings of the ... JSME Conference on Frontiers in Bioengineering   2008 ( 19 )   125 - 126   2008.9

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 401 Detection algorithm construction of flexible Six-Axis Force/Torque sensing system

    MORIJIRI Takeshi, Ota Masahiro, ODA Masafumi, HARA Toshiaki, KOZAKAI Akifumi

    2008 ( 45 )   107 - 108   2008.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 411 Fundamental study on automotive design system for NPPV nasal mask

    NINOMIYA Keiichi, YOSHIDA Yusuke, ODA Masafumi, HARA Toshiaki

    2008 ( 45 )   125 - 126   2008.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 408 Ultrasonic Technique for Arthrodial Cartilage Estimation

    KOGURE Hidetomo, ODA Masafumi, HARA Toshiaki

    2008 ( 45 )   119 - 120   2008.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 420 Mechanical characteristic analysis of thorax

    OOKAWA Hisashi, SUZUKI Yuusi, KANETA Yuutaku, ODA Masafumi, HARA Toshiaki

    2007 ( 20 )   161 - 162   2008.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 409 Computational and Biomechanical Estimation of BiCONTACT THA model

    HANDA Toshihiro, ODA Masafumi, Omori Go, HARA Toshiaki, Sugai Genta

    2007 ( 20 )   139 - 140   2008.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 915 The Analytical development for THA personal model using CT image for the loosening prediction

    HANDA Toshihiro, ODA Masafumi, Omori Go, HARA Toshiaki, Sugai Genta

    2007 ( 44 )   357 - 358   2007.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 912 The Acoustic characteristic of hitting sound of the crubeen

    OOKAWA Hisashi, SAITO Naoki, KANETA Yuutaku, ODA Masafumi, HARA Toshiaki

    2007 ( 44 )   351 - 352   2007.3

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • Annual report

    1 ( 1 )   109 - 112   2007.3

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (bulletin of university, research institution)  

    CiNii Article

    CiNii Books

    researchmap

    Other Link: http://hdl.handle.net/10191/5964

  • 429 The fundamental study on the haptic sensor using Pressure-Sensitive Conductive Rubber

    NAKAJIMA Satoshi, MORIJIRI Takeshi, ODA Masafumi, HARA Toshiaki, KOSAKAI Akifumi

    2006 ( 19 )   358 - 359   2007.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 222 A fundamental study on sound made from lower extremity subjected to impact load

    SAITO Naoki, OOKAWA Hisashi, KOURAKATA Itaru, ODA Masafumi, HARA Toshiaki

    2006 ( 19 )   268 - 269   2007.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 超音波による下腿義足ソケット装着部の3次元生体形状計測

    小野創平, 尾田雅文, 坂本信, 寺島和浩, 原利昭

    バイオエンジニアリング講演会講演論文集   18th ( 18 )   447 - 448   2006.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    J-GLOBAL

    researchmap

  • 513 The Pressure-Sensitive Electric Conductive Rubber technique for detecting tangential force

    NAKAJIMA Satoshi, ODA Masafumi, HARA Toshiaki, UOTANI Toshiaki, DOENNI Andreas, KAMATA Yoshitaka

    2005 ( 18 )   325 - 326   2006.1

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    CiNii Article

    CiNii Books

    researchmap

  • 超音波による人工股関節の接触メカニズム評価

    尾田雅文

    非破壊検査 -検査と材料評価-   53 ( 12 )   776 - 777   2004.12

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (scientific journal)   Publisher:日本非破壊検査協会  

    CiNii Article

    CiNii Books

    researchmap

  • Ultrasonic technique for detecting the position of soft tissue and bone

    ASAI Kanako, HANAFUSA Akihiko, ODA Masafumi, FUWA Teruhiko, HARA Toshiaki

    The JSME Symposium on Welfare Engineering   209 - 212   2003

     More details

    Language:Japanese   Publisher:The Japan Society of Mechanical Engineers  

    Fitting sockets techniques, which lower limb mainly affects prostheses, using laser measuring and CAD/CAM are approached, but skilled engineer is behooved when shapes of socket are determined. On the other hand, if stress affect on soft tissues, when the amputee fits the lower limb prosthesis can be calculated, accurate fitting operation will be facilitating. To solve these problems, the ultrasonic 3-D shape measurement system was carried out, that can measure soft tissue and bone. The echo from each soft tissue was measured to construct 3-D finite element model, and investigated extraction of the position of each echo pattern. Echo pattern were estimated through wavelet analysis, and it was shown that each boundary of soft tissue could be distinguished. Based on these echo reflection time, each thickness of soft tissue is calculated, and each coordinate value can be founded. These coordinates are reconstructed on 3-D coordinate axis of this measurement system, and we suggested the possibility of the construct of 3-D lower limb model.

    CiNii Article

    CiNii Books

    researchmap

  • 超音波身体計測を考慮した軟部組織の応力解析手法の検討

    尾田雅文

    第18回ライフサポート学会大会講演論文集, 2002   18   326 - 327   2002

  • 超音波波形のWavelet解析を利用した応力測定

    尾田雅文

    検査技術   5 ( 6 )   8 - 11   2000.6

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (trade magazine, newspaper, online media)   Publisher:日本工業出版  

    CiNii Article

    CiNii Books

    researchmap

  • A study on non-contact point-of-sight detection using a stereo image processing

    98 ( 31 )   222 - 226   1998.10

     More details

    Language:Japanese  

    CiNii Article

    researchmap

  • 超音波による人工股関節の接触メカニズム評価

    尾田雅文

    超音波TECHNO   11 ( 8 )   44 - 47   1998.8

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (trade magazine, newspaper, online media)   Publisher:日本工業出版  

    researchmap

  • 超音波法による人工股関節の接触メカニズム評価

    尾田 雅文, 鹿俣 丞, 原 利昭

    ジョイント・シンポジウム   96 ( 20 )   272 - 275   1996.10

     More details

    Language:Japanese   Publisher:日本機械学会  

    CiNii Article

    researchmap

  • The Estimation of Mechanical Properties of Trabecular Bone by an Ultrasonic Technique.

    坂本信, 坂井淳, 尾田雅文, 夏目実, 鹿俣丞, 原利昭

    日本機械学会通常総会講演会講演論文集   73rd ( Pt 1 )   464 - 465   1996.4

     More details

    Language:Japanese  

    J-GLOBAL

    researchmap

  • 技術高度化指針(機械Ⅰ 設計・組立)

    斎藤博, 長谷川光彦, 磯部達夫, 吉原英雄, 土佐進, 廣井晃, 野中敏, 坂井修, 尾田雅文, 柴山勉

    技術高度化指針(機械Ⅰ 設計・組立)   1992.3

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (other)   Publisher:新潟県商工労働部  

    researchmap

  • 技術高度化指針(作業工具)

    渡部豈臣, 高野英資, 長谷川直, 兼古耕一, 佐藤則明, 横田優治, 紫竹耕司, 尾田雅文, 木村文夫

    技術高度化指針(作業工具)   1990.3

     More details

    Language:Japanese   Publishing type:Article, review, commentary, editorial, etc. (other)   Publisher:新潟県商工労働部  

    researchmap

▶ display all

Presentations

  • 工学的アプローチによるステムのショート化が及ぼす初期固定性の検討 Invited

    尾田雅文

    第5回 Hip Implant Technology 研究会  2020.2  Hip Implant Technology 研究会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:福岡国際会議場  

    researchmap

  • 足関節自動運動装置による下肢の血流改善効果への影響

    横山翔平, 笹川圭右, 尾田雅文, 蛭川浩史

    日本機械学会 第32回バイオエンジニアリング講演会  2019.12  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:金沢商工会議所会館  

    researchmap

  • 骨折リスクにおける骨密度の影響

    笹川圭右, 尾田雅文, 佐藤 朗, 原利昭

    第46回日本臨床バイオメカニクス学会  2019.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:久留米シティープラザ  

    researchmap

  • 大腿骨近位部骨折と破壊力学

    佐藤朗, 湊 泉, 笹川圭右, 原 利昭, 尾田雅文

    第46回日本臨床バイオメカニクス学会  2019.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:久留米シティープラザ  

    researchmap

  • 髄内釘インプラントの形状が骨折部固定性に与える影響

    佐野匠, 笹川圭右, 尾田雅文, 塩田直史

    日本機械学会2019年度年次大会  2019.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:秋田大学 手形キャンパス  

    researchmap

  • パラアイスホッケー用スレッジのフレーム形状に対する強度評価

    阿部佳峻, 笹川圭右, 尾田雅文, 川越健矢

    日本機械学会2019年度年次大会  2019.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:秋田大学 手形キャンパス  

    researchmap

  • 骨折部固定性に与えるインプラントの軸径の影響 International conference

    佐野匠, 笹川圭祐, 尾田雅文, 塩田直史

    日本機械学会北陸信越支部第56期総会・講演会  2019.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 大腿骨転子下骨折の骨折部固定性に及ぼす髄内釘長さの生体力学的評価

    佐野匠, 笹川圭右, 尾田雅文

    第45回 日本臨床バイオメカニクス学会  2018.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:秋田アトリオン  

    researchmap

  • 腸骨大腿靭帯を考慮した大腿骨近位部骨折の骨折リスクと骨密度との関係

    笹川圭右, 櫻井航太, 尾田雅文

    第45回 日本臨床バイオメカニクス学会  2018.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:秋田アトリオン  

    researchmap

  • 大腿骨転子部骨折を破壊力学的に曲げとねじりで考察する

    佐藤朗,湊泉, 尾田雅文

    第45回 日本臨床バイオメカニクス学会  2018.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:秋田アトリオン  

    researchmap

  • 下肢の血流改善における持続的足関節運動の検討

    横山翔平, 笹川圭右, 尾田雅文, 蛭川浩史

    日本機械学会2018年度年次大会  2018.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:大阪工業大学梅田キャンパス  

    researchmap

  • 大腿骨転子下骨折モデルに対する髄内釘長さの影響

    佐野匠, 櫻井航太, 笹川圭右, 尾田雅文

    日本機械学会2018年度年次大会  2018.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:大阪工業大学梅田キャンパス  

    researchmap

  • 大腿骨近位部骨折における腸骨大腿靭帯の影響

    笹川圭右, 櫻井航太, 尾田雅文

    日本機械学会2018年度年次大会  2018.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:大阪工業大学梅田キャンパス  

    researchmap

  • 小型スクリューを併用した髄内釘固定術の力学的検討

    笹川圭右, 田中啓太, 尾田雅文, 前原孝

    日本機械学会北陸信越支部第55期総会・講演会  2018.3  日本機械学会北陸信越支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:福井工業大学  

    researchmap

  • 大腿骨有限要素モデルにおける腸骨大腿骨靭帯を考慮した骨折評価

    櫻井航太, 笹川圭右, 尾田雅文, 佐藤朗

    日本機械学会北陸信越支部第55期総会・講演会  2018.3  日本機械学会北陸信越支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:福井工業大学  

    researchmap

  • 大腿骨転子部骨折における髄内釘型インプラントと小径スクリュー併用による内固定への影響

    田中啓太, 笹川圭右, 尾田雅文, 前原孝

    第30回バイオエンジニアリング講演会  2017.12  日本機械学会

     More details

    Language:Japanese   Presentation type:Poster presentation  

    Venue:京都大学・百周年時計台記念館  

    researchmap

  • 腸骨大腿靭帯を考慮した大腿骨近位部の骨折リスク評価

    櫻井航太, 笹川圭右, 尾田雅文, 佐藤朗

    第44回日本臨床バイオメカニクス学会  2017.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:松山市総合コミュニティ―センター  

    researchmap

  • 大腿骨転子部骨折における髄内釘のインプラント長さが与える骨折部固定性への影響

    笹川圭右, 尾田雅文, 塩田直史

    第44回日本臨床バイオメカニクス学会  2017.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:松山市総合コミュニティ―センター  

    researchmap

  • 大腿骨転子下骨折における髄内釘システムの選択

    笹川圭右, 尾田雅文, 原利昭, 塩田直史

    20017年度日本機械学会年次大会  2017.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:埼玉大学  

    researchmap

  • 骨折メカニズムを念頭に大腿骨転子部骨折の3D-CT・X線を読影する

    佐藤朗, 尾田雅文

    第5回日本脆弱性骨折ネットワーク  2017.3  日本脆弱性骨折ネットワーク

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:新潟市民プラザ  

    researchmap

  • 大腿骨転子下骨折の髄内釘固定術モデルに対するねじりの影響

    野口愛子, 笹川圭右, 尾田雅文, 塩田直史, 佐藤徹, 原利昭

    第43回日本臨床バイオメカニクス学会  2016.10  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:北海道立道民活動センター かでる  

    researchmap

  • 人工股関節ステムの弾性率傾斜モデルによる生体力学的解析

    田中啓太, 笹川圭右, 尾田雅文, 原利昭, 櫻井航太, 野口愛子, 山田崇史

    第43回日本臨床バイオメカニクス学会  2016.10  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:北海道立道民活動センター かでる  

    researchmap

  • 数値解析手法を用いた人工股関節ステムの最適形状設計

    笹川圭右, 櫻井航太, 尾田雅文, 原利昭, 田中啓太, 中田活也

    第43回日本臨床バイオメカニクス学会  2016.10  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:北海道立道民活動センター かでる  

    researchmap

  • Relationship between the shape and the primary stability for artificial hip stem International conference

    SAKURAI Kota, SASAGAWA Keisuke, ODA Masafumi, HARA Toshiaki, NAKATA Katsuya

    Asia-Pacific Conference on Fracture and Strength 2016  2016.9  JSME

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:Toyama International Convention Center  

    researchmap

  • Finite Element Analysis on Intramedullary Nail Fixation for FemoralSubtrochanteric Fracture International conference

    NOGUCHI Aiko, SASAGAWA Keisuke, ODA Masafumi, SHIOTA Naofumi, SATO Toru, HARA Toshiaki

    Asia-Pacific Conference on Fracture and Strength 2016  2016.9  JSME

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:Toyama International Convention Center  

    researchmap

  • サポートベクターマシンによる官能評価を用いた教育評価システムの研究

    小暮ミカ, 尾田雅文

    日本補綴歯科学会第125回学術大会  2016.7  日本補綴歯科学会

     More details

    Language:Japanese   Presentation type:Poster presentation  

    Venue:ANAクラウンプラザ金沢  

    researchmap

  • 3次元脊椎アライメント評価におけるEOSシステムとCTモデルの比較

    安澤拓真, 笹川圭右, 長谷川和宏, 岡本昌士, 尾田雅文, 原利昭

    日本機械学会 北陸信越支部第53期総会・講演会  2016.3  日本機械学会 北陸信越支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:信州大学工学部  

    researchmap

  • 脊椎アライメントの三次元評価におけるsterEOSを用いた精度検証

    安澤拓真, 笹川圭右, 長谷川和宏, 岡本昌士, 尾田雅文, 勝山恵子, 原利昭

    日本機械学会第28回バイオエンジニアリング講演会  2016.1  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:東京工業大学 大岡山キャンパス  

    researchmap

  • 褥瘡予防用セミオーダー型シリコーンゴム製クッションの試作

    寺島正二郎, 尾田雅文, 勝山恵子, 笹川圭右, 原利昭, 田中正喜, 池野正行

    日本機械学会第28回バイオエンジニアリング講演会  2016.1  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:東京工業大学 大岡山キャンパス  

    researchmap

  • 大腿骨転子下骨折偽関節に対するaugment plateを用いた追加手術の有用性 -有限要素解析による検討―

    塩田直史, 佐藤徹, 野口愛子, 笹川圭右, 尾田雅文, 勝山恵子, 原利昭

    第42回日本臨床バイオメカニクス学会  2015.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:ソラシティ カンファレンスセンター  

    researchmap

  • 人工股関節ステム形状が及ぼす初期固定性の影響に関する数値解析的検討

    櫻井航太, 笹川圭右, 勝山恵子, 原利昭, 尾田雅文, 中田活也

    第42回日本臨床バイオメカニクス学会  2015.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:ソラシティ カンファレンスセンター  

    researchmap

  • Finite Element Analysis on Intramedullary Nail Fixation for Femoral Subtrochanteric Fracture International conference

    Aiko NOGUCHI, Keisuke SASAGAWA, Masafumi ODA, Naofumi SHIOTA, Toru SATO, Toshiaki HARA

    The 8th Asian-Pacific Conference on Biomechanics  2015.9  The Japan Society of Mechanical Engineers

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:Hokkaido University  

    researchmap

  • Relationship between the shape and the primary stability for artificial hip stem International conference

    Kota SAKURAI, Keisuke SASAGAWA, Masafumi ODA

    The 8th Asian-Pacific Conference on Biomechanics  2015.9  The Japan Society of Mechanical Engineers

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:Hokkaido University  

    researchmap

  • 人工股関節ステム形状変化による初期固定性の影響

    櫻井航太, 笹川圭右, 勝山恵子, 尾田雅文, 中田活也, 寺島正二郎, 原利昭

    日本機械学会第27回バイオエンジニアリング講演会  2015.1  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:朱鷺メッセ  

    researchmap

  • 多発骨盤骨折の内固定における高齢者姿勢を考慮した力学解析

    野口愛子, 勝山恵子, 笹川圭右, 尾田雅文, 塩田直史, 寺島正二郎, 原利昭

    日本機械学会第27回バイオエンジニアリング講演会  2015.1  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:朱鷺メッセ  

    researchmap

  • 有限要素法による損傷椎間板の物性推定 International conference

    笹川圭右, 尾田雅文, 勝山恵子, 長谷川和宏, 原利昭, 寺島正二郎

    日本機械学会第27回バイオエンジニアリング講演会  2015.1  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:朱鷺メッセ  

    researchmap

  • 大腿骨転子下骨折の髄内釘固定術モデルにおける力学的検討

    野口愛子, 笹川圭右, 尾田雅文, 勝山恵子, 塩田直史, 原利昭

    第42回日本臨床バイオメカニクス学会  2015.1  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:ソラシティ カンファレンスセンター  

    researchmap

  • 脊椎固定デバイスの機能的強度に関するFE 解析

    笹川圭右, 尾田雅文, 勝山恵子, 長谷川和宏, 原利昭, 寺島正二郎

    日本機械学会2014年度年次大会  2014.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 大腿骨ステム埋植部のマイクロモーションによる初期固定性とステム長の関係

    櫻井航太, 安澤拓真, 笹川圭右, 勝山恵子, 尾田雅文, 中田活也, 寺島正二郎, 原利昭

    日本機械学会 北陸信越支部第51期総会・講演会  2014.3  日本機械学会 北陸信越支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 多発骨盤骨折の内固定における力学解析

    野口愛子, 勝山恵子, 笹川圭右, 尾田雅文, 塩田直史, 寺島正二郎, 原利昭

    日本機械学会 北陸信越支部第51期総会・講演会  2014.3  日本機械学会 北陸信越支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 改良型術中脊椎不安定性評価システムの試用

    小林史法, 寺島正二郎, 笹川圭右, 勝山恵子, 尾田雅文

    日本機械学会 北陸信越支部第51期総会・講演会  2014.3  日本機械学会 北陸信越支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 複雑骨折骨盤プレート固定部のFEM解析

    野口愛子, 勝山恵子, 笹川圭右, 尾田雅文, 塩田直史, 原利昭

    第24回バイオフロンティア講演会  2013.10  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • ショート型人工股関節ステムの初期固定性評価

    笹川圭右, 尾田雅文, 勝山恵子, 原利昭

    日本機械学会2013年度年次大会  2013.9  日本機械学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    researchmap

  • ショート型人工股関節ステムの有限要素解析 International conference

    笹川圭右, 尾田雅文, 勝山恵子, 中田克也, 原利昭, 寺島正二郎

    日本機械学会北陸信越支部第50期総会・講演会  2013.3  日本機械学会北陸信越支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 実習成果物の客観的形態評価システムの開発

    木暮 ミカ, 早川 淳, 伊藤 圭一, 大沼 誉英, 河野 正司, 尾田 雅文, 東村 明宏

    日本歯科技工学会第34回学術大会  2012.9  日本歯科技工学会

     More details

    Language:Japanese   Presentation type:Poster presentation  

    Venue:岡山コンベンションセンター  

    researchmap

  • Stability Evaluation of the Silicone Mattress for Pressure Ulcer Prevention

    Hirohito MUKAE, Masafumi ODA

    2012.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Elicitation technique for controlled parameter of Computer-assisted hydrodynamic gene delivery

    Noriaki OTSUKA, Masafumi ODA

    2012.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 医薬工連携による新規遺伝子導入装置の開発と今後の展開

    上村顕也, 須田剛士, 尾田雅文

    日本DDS学会学術集会  2012  日本DDS学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Psychophysical Evaluation of Postural Change for prevention of decubitus

    H.MUKAE, M.ODA, T.HARA, M.TANAKA

    2011.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Biomechanical Evaluation for Primary Stability of Tapered Wedge-Shaped Stem for Type C Bone International conference

    Katsuya Nakata, Mitsuyoshi Yamamura, Takeshi Fuji, Kazuomi Sugamoto, Hideki Yoshikawa, Go Yamako, Masafumi Oda, Toshiaki Hara

    2011 Annual Meeting  2011.2  The American Academy of Orthopaedic Surgeons

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:San Diego Convention C  

    researchmap

  • The high lateral resolution imaging method using by ultrasonic technique for 3D modeling

    Tomomi TAKEDA, Masafumi ODA, Toshiaki HARA, Takeshi SUDA, Kenya KAMIMURA

    2011.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Development of electromotor-driven system for hydrodynamic gene delivery

    Suda T, Imai T, Kamimura K, Oda M, Kanefuji T, Zhang G, Liu D, Yokoo T, Tamura Y, Igarashi M, Kawai H, Aoyagi Y

    THE 16th ANNUAL MEETING JSGT2010  2010.7  JAPAN SOCIETY OF GENE THERAPY

     More details

    Language:English   Presentation type:Poster presentation  

    Venue:Tochigi-ken General Culture Center  

    researchmap

  • 楔状テーパー型ステムの固定性と大腿骨髄腔形状 ―初期固定性の生体力学的解析を加えて―

    中田 活也, 山村 在慶, 尾田 雅文

    第83会日本整形外科学会学術総会  2010.5  日本整形外科学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:東京国際フォーラム/よみうりホール  

    researchmap

  • Gene therapy equipment made onan experimental basis of hepatic disease

    Tsuyoshi IMAI, Masafumi ODA, Toshiaki HARA, Takeshi SUDA

    2010.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • A study on noize elimination method considering temporal axis in ultrasonic images

    Tomomi TAKEDA, Masafumi ODA, Toshiaki HARA

    2010.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Detection of dynamic information using hybrid haptic sensor

    Masahiro OHTA, Hirohito MUKAE, Masafumi ODA, Toshiaki HARA, Akifumi KOZAKAI

    2010.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Mechanical evaluation for fitting of NPPV nasal mask

    Yusuke YOSHIDA, Keiichi NINOMIYA, Masafumi ODA, Toshiaki HARA

    2009.11 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 超音波画像の鮮明化に基づく人体パーソナルモデリング

    尾田雅文

    イノベーションジャパン2009  2009.9  科学技術振興機構,新エネルギー・産業技術総合開発機構

     More details

    Language:Japanese   Presentation type:Poster presentation  

    Venue:東京国際フォーラム  

    researchmap

  • Internship program for highly educated people and intellectual property instruction

    ODA Masafumi, GOTOH Takao, NAGAHAMA Katsusuke, HATAKEYAMA Miyoko, TSUBOKAWA Norio, HARA Toshiaki

    2009.6 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Fundamental study on wavelet-based improvement of ultrasonic images

    TAKEDA Tomomi, ODA Masafumi, Hara Toshiaki

    2009.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Impact Response Analysis of Thorax Structure

    OOKAWA Hisashi, SUZUKI Yuji, KANETA Yutaku, ODA Masafumi, HARA Toshiaki

    2009.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Force evaluation for scalpel operation by using electrical capacitance multi-axis force sensor

    OTA Masahiro, ODA Masafumi, HARA Toshiaki, KOZAKAI Akifumi

    2009.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 術前・術後CT 画像に基づく患者別セメントレスステム大腿骨の初期固定性評価

    山子剛, 樋浦 耐, 中田 活也, 堂前洋一郎, 大森豪, 尾田雅文, 原利昭

    第35回日本臨床バイオメカニクス学会講演会  2008.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • NPPV鼻マスク装着部の応力解析のためのパーソナル対応FEモデル構築

    尾田雅文, 小浦方格

    日本非破壊検査協会平成20年度秋季大会  2008.11  日本非破壊検査

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Fundamental study on the adaptive design system for NPPV nasal mask

    Yusuke YOSHIDA, Keiichi NINOMIYA, Masafumi ODA, Toshiaki HARA

    2008.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 中越沖地震における地場産業の被害と復興状況

    尾田雅文, 小浦方格, 原利昭

    日本機械学会2008年度年次大会  2008.8  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (invited, special)  

    Venue:横浜国立大学  

    researchmap

  • 6 軸荷重センシング検出アルゴリズムの構築

    森尻 剛史, 太田 昌宏, 尾田 雅文, 原 利昭, 小坂井 暁史

    日本機械学会北陸信越支部第45期総会・講演会  2008.3  日本機械学会北陸信越支部

     More details

    Language:English   Presentation type:Oral presentation (general)  

    researchmap

  • 超音波関節鏡システムによる関節軟骨疾患の評価

    木暮秀友, 尾田雅文, 原利昭

    日本機械学会北陸信越支部第45期総会・講演会  2008.3  日本機械学会北陸信越支部

     More details

    Language:English   Presentation type:Oral presentation (general)  

    researchmap

  • Fundamental study on automotive design system for NPPV nasal mask

    Keiichi NINOMIYA, Yusuke YOSHIDA, Masafumi ODA, Toshiaki HARA

    2008.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Computational and Biomechanical Estimation of BiCONTACT THA model

    Toshihiro HANDA, Masafumi ODA, Go Omori, Toshiaki HARA, Genta Sugai

    2008.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Mechanical characteristic analysis of thorax

    Hisashi OHKAWA, Yushi SUZUKI, Yutaka KANETA, Masafumi ODA, Toshiaki HARA

    2008.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Wavelet Transform for Evaluation of An Arthrodial Cartilage

    Hidetomo KOGURE, Masafumi ODA, Toshiaki HARA

    2007.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 手術支援システム用センサの基礎研究

    森尻剛史, 尾田雅文, 原利昭, 小坂井暁史

    日本機械学会年次大会  2007.9  日本機械学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    researchmap

  • 国際的な産学官連携を進める上での問題となるアジア各国と日本の特許制度における相違点に関する調査研究 -中国・韓国・ロシアについて-

    尾田雅文

    国際産学官連携フォーラム  2007.6  東京工業大学

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:一橋記念講堂  

    researchmap

  • The Analytical development for THA personal model using CT image

    Toshihiro HANDA, Masafumi ODA

    2007.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Acoustic characteristic of hitting sound made from lower extremity

    Naoki SAITO, Hisashi OOKAWA, Yuutaku KANETA, Masafumi ODA, Toshiaki HARA

    2007.3 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 感圧導電ゴムを用いた対象物の触感検出に関する基礎的研究

    中島賢志, 森尻剛史, 尾田雅文

    第19回バイオエンジニアリング講演会  2007.1  日本機械学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    researchmap

  • A fundamental study on sound made from lower extremity subjected to impact load

    SAITO Naoki, OOKAWA Hisashi, KOURAKATA Itaru, ODA Masafumi, HARA Toshiaki

    2007.1 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • The Fundamental Research on Optimum Design for NIPPV Nasal Mask

    Keiichi NINOMIYA, Toshihiro HANDA, Masafumi ODA, Toshiaki HARA

    2006.10 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 下腿義足ソケット形状支援システムの試作とソケット内接触圧力の評価

    小野創平, 尾田雅文, 寺島和浩, 原利昭

    日本機械学会2006年度年次大会講演  2006.10  日本機械学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:熊本大学  

    researchmap

  • Ultrasonic screw hole detection of the intramedullary nail

    YAGI Takeo, KAWANA Takumi, UMENO Takatoshi, ODA Masafumi, HARA Toshiaki

    2006.9 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 感圧性導電ゴムを用いたトラクション荷重検出に関する基礎的研究

    中島賢志, 尾田雅文

    第18回バイオエンジニアリング講演会  2006.1  日本機械学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:朱鷺メッセ  

    researchmap

  • 超音波による下腿義足ソケット装着部の3次元生体形状計測

    小野創平, 尾田雅文

    第18回バイオエンジニアリング講演会  2006.1  日本機械学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:朱鷺メッセ  

    researchmap

  • Trial Development of Biomechanical Shape Measurement System Using Technique in Consideration of Internal Tissue Shape

    Souhei ONO, Masafumi ODA, Toshiaki HARA

    2005.10 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Research on Ultrasound Shape Measurement System for the Body Surface and Skelton

    Kanako ASAI, Akihiko HANAFUSA, Teruhiko FUWA, Masafumi ODA

    2004.7 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Research on Optimum Shape Design System for Prosthetic Sockets International conference

    Akihiko HANAFUSA, Teruhiko FUWA, Masafumi ODA, Ttsuyoshi NAKAYAMA

    2004.5 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 超音波エコーの Wavelet 解析による軟部組織・骨同時計測手法の検討 International conference

    浅井協子, 花房昭彦, 尾田雅文, 不破輝彦, 原利昭

    日本機械学会第3回福祉工学シンポジウム  2003.10  日本機械学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:東京  

    researchmap

  • 超音波身体計測を考慮した軟部組織の応力解析手法の検討

    尾田雅文

    第18回ライフサポート学会大会  2002.9  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:富山県立大学  

    researchmap

  • Matching Pursuit Technique Estimation for Non-Contact Eye-Gazing Point Detection

    ODA Masafumi, ISOMURA Tsuneshi, SEKIGUCHI Yukio, HARA Toshiaki

    2001.10 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 車椅子移動シミュレータ使用時の視点位置移動特性評価

    尾田雅文

    第17回ライフサポート学会大会  2001.8  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:東京  

    researchmap

  • Wavelet変換を適用した2次元多重解像度解析による非接触視点位置検出に関する研究 International conference

    鉄谷聖和, 尾田雅文

    人と福祉を支える技術フォーラム・2001  2001.2  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • Non-Contact Eye-Gazing Point Detection Technique via Two Dimensional Multi Resolution Analysis

    TETSUTANI Kiyokazu, SHUTO Yuriko, ODA Masafumi, ISOMURA Tsunesh, SEKIGUCHI Yukio, HARA Toshiaki

    2000.10 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 2次元多重解像度解析を利用した非接触視点位置検出法の改良

    首藤由里子, 尾田雅文

    第16回ライフサポート学会大会  2000.8  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:徳島  

    researchmap

  • 動的荷重条件下における人工股関節コンポーネントの歪量評価

    帆足雅晃, 尾田雅文

    第16回ライフサポート学会大会  2000.8  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:徳島  

    researchmap

  • 2次元MRAを利用した非接触視点位置検出法の検討

    尾田雅文

    第15回ライフサポート学会大会  1999.10  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:神奈川  

    researchmap

  • A study on non-contact point-of-sight detection using a stereo image processing

    ODA Masafumi, Hara Toshiaki

    1998.10 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • ステレオ画像法による非接触視線検出システム International conference

    尾田雅文

    第14回ライフサポート学会大会  1998.10  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:東京  

    researchmap

  • 超音波による人工股関節ソケットの接触メカニズム評価 International conference

    尾田雅文

    日本機械学会第10回バイオエンジニアリング講演会  1998.1  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:広島大学  

    researchmap

  • 超音波を利用した人工股関節の接触メカニズム評価法の検討 International conference

    尾田雅文

    第13回ライフサポート学会大会  1997.10  ライフサポート学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:共立薬科大学  

    researchmap

  • 椎体shellの弾性異方性

    杉浦享, 鷲尾利克, 原利昭, 坂本信, 尾田雅文

    第23回日本臨床バイオメカニクス学会  1996.11  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:東京  

    researchmap

  • 超音波法による人工股関節の接触メカニズム評価

    尾田 雅文, 鹿俣 丞, 原 利昭

    ジョイント・シンポジウム1996:スポーツ工学,ヒューマン・ダイナミクス  1996.10  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 圧縮試験法と超音波法を用いた海面骨力学的特性評価 International conference

    坂井淳, 坂本信, 尾田雅文, 夏目実, 原利昭

    第22回日本臨床バイオメカニクス学会  1995.10  日本臨床バイオメカニクス学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    researchmap

  • 超音波法による摺動時のせん断応力評価

    夏目実, 尾田雅文, 原利昭

    日本機械学会第73期全国大会  1995.9  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:九州産業大学  

    researchmap

  • 超音波法を利用した摩擦によるせん断応力の評価 International conference

    夏目実, 尾田雅文, 原利昭

    日本機械学会北陸信越支部第32期総会・講演会  1995.3  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:新潟  

    researchmap

  • 反射超音波の時間-周波数解析を用いたゴム摺動時の接触圧力測定

    尾田雅文, 原利昭

    日本機械学会第72期全国大会講演論文集  1994.8  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:札幌  

    researchmap

  • ゴム摺動面のアブレージョンパターンに及ぼすスティックスリップ現象の影響 International conference

    尾田雅文, 原利昭

    日本機械学会第71期通常総会講演会  1994.3  日本機械学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:東京  

    researchmap

  • 超音波による接触域端部の接触圧力評価

    尾田雅文, 原利昭

    日本トライボロジー学会トライボロジー会議  1993.11  日本トライボロジー学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:名古屋  

    researchmap

  • 新素材等の耐摩耗特性に関する研究(第2報:TiN薄膜の密着性特性) International conference

    尾田雅文, 高野格, 田中亙, 桂沢豊, 原利昭

    日本潤滑学会トライボロジー会議  1992.5  日本潤滑学会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    Venue:東京  

    researchmap

  • プラズマCVD法によるTiN薄膜のトライボロジー特性

    尾田雅文, 高野格, 桑原猛, 田中亙, 桂沢豊

    平成3年度日本セラミクス協会東北北海道支部研究発表会  1991.10  日本セラミクス協会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:新潟  

    researchmap

  • 新素材等の耐摩耗特性に関する研究(ほう化処理材のAE発生特性) International conference

    尾田雅文, 高野格, 田中亙, 桂沢豊, 原利昭

    トライボロジー会議(東京1991)  1991.5  日本潤滑学会

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:東京  

    researchmap

  • 各種基板へのプラズマCVD法によるTiN薄膜の生成と評価 International conference

    高橋祐一, 渡辺健彦, 大塩洋輔, 野中敏, 桑原猛, 尾田雅文, 溝田隆之, 降屋幹男

    表面技術協会第82回講演大会  1990.10  表面技術協会

     More details

    Language:English   Presentation type:Oral presentation (general)  

    researchmap

  • プラズマCVD法により生成したTiN薄膜の摩耗特性 International conference

    尾田雅文, 桑原猛, 高橋祐一, 渡辺健彦, 大塩洋輔

    平成2年度支部連合講演会  1990.3  日本金属学会北陸信越支部日本鉄鋼協会北陸支部

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Venue:新潟  

    researchmap

▶ display all

Industrial property rights

  • 腸内洗浄用具

    尾田雅文

     More details

    Application no:特願2017-040966  Date applied:2017.3

    Patent/Registration no:特許6845471  Date registered:2021.3 

    researchmap

  • 術前計画骨モデルの作製方法

    尾田雅文, 鶴間明, 原利昭, 笹川圭右, 勝山恵子

     More details

    Application no:特願2013-220505  Date applied:2013.10

    researchmap

  • 褥瘡予防用マットレス

    尾田雅文

     More details

    Application no:特願2012-15858  Date applied:2012.1

    Patent/Registration no:特許5776569  Date registered:2015.7  Date issued:2015

    researchmap

  • Image processing system and method

    Masafumi ODA, Tomoki TAKEDA

     More details

    Applicant:Niigata University

    Application no:2009‐204635  Date applied:2009.9

    researchmap

  • マスク形状決定支援システム,マスク形状決定支援方法およびマスク形状決定支援プログラム

    尾田雅文

     More details

    Applicant:国立大学法人新潟大学

    Application no:特願2008-308075  Date applied:2008.12

    researchmap

  • 触覚センサ

    尾田雅文

     More details

    Applicant:国立大学法人新潟大学,外1組織

    Application no:特願2007-227156  Date applied:2007.8

    Announcement no:特開2009-58445  Date announced:2009.3

    researchmap

  • 物理量導出装置、物理量導出プログラム及び物理量導出方法

    尾田 雅文

     More details

    Applicant:国立大学法人新潟大学,外1組織

    Application no:特許出願2007-56  Date applied:2007.1

    Announcement no:特許公開2008-164556  Date announced:2008.7

    researchmap

  • 触覚センサ

    尾田 雅文

     More details

    Applicant:国立大学法人新潟大学,他1組織

    Application no:特願2007-57  Date applied:2007.1

    Announcement no:特許公開2008-164557  Date announced:2008.7

    researchmap

  • Data from the 3-dimensional measurement equipment and prosthetic socket device

    ODA Masafumi

     More details

    Applicant:Niigata University

    Application no:特許出願2005-77834  Date applied:2005.3

    Announcement no:特許公開2006-255199  Date announced:2006.9

    Patent/Registration no:特許第4304341号  Date issued:2009.5

    researchmap

▶ display all

Research Projects

  • Development of DVT prevention equipment

    Grant number:20K12753

    2020.4 - 2023.3

    System name:Grants-in-Aid for Scientific Research

    Research category:Grant-in-Aid for Scientific Research (C)

    Awarding organization:Japan Society for the Promotion of Science

      More details

    Grant amount:\1690000 ( Direct Cost: \1300000 、 Indirect Cost:\390000 )

    researchmap

  • 地域医療機関と連携したバイオメカニクスを基盤とする術前検討・術中支援システム開発プロジェクト

    2015.4 - 2018.3

    System name:その他の研究制度

      More details

    Grant type:Competitive

    バイオメカニクス分野は、整形外科分野および消化器外科分野との結びつきにより、欧米では治療方法や治療技術での顕著な成果が得られている。本プロジェクトでは、これまで医療機関と連携を図ってきた特異な研究体制基盤と協業力を生かして、整形外科分野の骨折治療、脊椎治療において、これまでの医師の経験値による外科インプラント治療に、バイオメカニクスに基づき、外科インプラントが骨格に与える影響を術前検討可能なシステムを地域医療機関との密な連携により、確実な治癒手法を目指す。

    researchmap

  • Hydrodynamic Gene Delivery to Non-human Primates

    Grant number:26860354

    2014.4 - 2018.3

    System name:Grants-in-Aid for Scientific Research

    Research category:Grant-in-Aid for Young Scientists (B)

    Awarding organization:Japan Society for the Promotion of Science

    KAMIMURA KENYA, Terai Shuji, Aoyagi Yutaka, Suda Takeshi, Yokoo Takeshi, Fujisawa Nobuyoshi, Yoshida Hidenori, Oda Masafumi, Liu Dexi

      More details

    Grant amount:\4030000 ( Direct Cost: \3100000 、 Indirect Cost:\930000 )

    gene therapy. We have previously reported the effectiveness of image-guided liver-lobe specific hydrodynamic gene delivery. Here, we have assessed the efficiency and the safety of the procedure in non-human primates in this study. The injection catheter was inserted in the lobular hepatic veins and the hydrodynamic injection of the marker plasmid DNA was performed with a various parameters including, injection pressure, volume, flow rate, etc. Based on the results obtained, the optimum parameters were defined followed by the long-term gene expression study using the parameters injecting plasmid expressing human factor IX DNA. The efficiency and safety of the procedure have been confirmed and the development of the gene delivery system and the pre-clinical study are ongoing research programs.

    researchmap

  • 新潟発・革新的脊椎診断/評価システムとインプラントの開発

    2013.4 - 2016.3

    System name:新規産業創造型提案公募制度

      More details

    Grant type:Competitive

    患者数が多く、高度の治療が必要な脊椎疾患に使用する高機能インプラント(低弾性化、レーザー加工によるカスタムメイド化)と共に、正確に脊椎機能を評価するシステムを併せて開発・改良する.
    再生医療技術やモデルサージェリーを併用したシミュレーション技術のソフトウエアを組み合わせ、患者も医師も共に安全確実な結果が期待出来る脊椎疾患用医療製品・診断装置を中心とする新しい医用デバイス市場の創出を目指す.

    researchmap

  • Development of hydrodynamic gene delivery system for the delivery to the mitochondria

    Grant number:24590961

    2012.4 - 2015.3

    System name:Grants-in-Aid for Scientific Research

    Research category:Grant-in-Aid for Scientific Research (C)

    Awarding organization:Japan Society for the Promotion of Science

    SUDA Takeshi, ODA Masafumi

      More details

    Grant amount:\5330000 ( Direct Cost: \4100000 、 Indirect Cost:\1230000 )

    Toward the development of a feasible mitochondrial gene therapy in clinic, the plasmids consist of a mitochondria-specific promotor and terminal signal with genes, which are modified for a mitochondria-specific codon usage, were developed, and we confirmed no expression from the plasmids in the nucleus using a confocal microscopy.
    Because hydrodynamic gene delivery could not efficiently deliver the plasmids to mitochondria, proteins binding to the mitochondrial localization signal were employed for enhancing the delivery. In order to prevent the dissociation between the localization signal and proteins, we newly developed hydrodynamic gene delivery injecting a half volume with a half speed of the authentic hydrodynamic delivery.
    Now we are evaluating the effectiveness of the modified hydrodynamic system in the delivery of the plasmids to the mitochondria in mice.

    researchmap

  • Development of the curriculum of university utilized the education system of the highly expertized companies

    Grant number:23531244

    2011.4 - 2015.3

    System name:Grants-in-Aid for Scientific Research

    Research category:Grant-in-Aid for Scientific Research (C)

    Awarding organization:Japan Society for the Promotion of Science

    MATSUBARA Sachio, ODA Masafumi, KAWASAKI Kazumasa, KOURAKATA Itaru, HIRASAWA Nobuyasu

      More details

    Grant amount:\1950000 ( Direct Cost: \1500000 、 Indirect Cost:\450000 )

    The purpose of this research is to develop the curriculum of university utilized the education system of highly expertized companies.
    This research is proceeded based on the best practice of tacit knowledge management of advanced expertise companies in Japan and Western countries.

    researchmap

  • ハイドロダイナミック遺伝子治療装置の制御パラメータ導出手法の開発

    2011.4 - 2014.3

    System name:科学研究費補助金

    Research category:基盤研究(C)

    Awarding organization:日本学術振興会

      More details

    Grant type:Competitive

    Grant amount:\4420000 ( Direct Cost: \3400000 、 Indirect Cost:\1020000 )

    物理的非ウイルスベクターによる遺伝子治療の臨床応用を目指し、犬やブタ等の大型動物における効率的かつ再現性の高い、局所的ハイドロダイナミック遺伝子導入のための新規導入システムの安全性確立を目的とする。すなわち、Good Clinical Practiceに準拠した遺伝子導入機を開発するとともに、安全にシステム制御可能なアルゴリズムを確立し、大型動物におけるその有用性の確認を行う。本研究を遂行することにより、疾患モデル大動物と非ヒト霊長類を用いた臨床試験前段階への移行が可能になると共に、薬物の細胞内直接送達という新規分野開拓に寄与する。

    researchmap

  • ハイドロダイナミック遺伝子治療装置の制御パラメータ導出手法の開発

    2011.4 - 2014.3

    System name:科学研究費助成事業

    Research category:基盤研究(C)

    Awarding organization:日本学術振興会

      More details

    Grant type:Competitive

    Grant amount:\4420000 ( Direct Cost: \3400000 、 Indirect Cost:\1020000 )

    物理的非ウイルスベクターによる遺伝子治療の臨床応用を目指し、犬やブタ等の大型動物における効率的かつ再現性の高い、局所的ハイドロダイナミック遺伝子導入のための新規導入システムの安全性確立を目的とする。すなわち、Good Clinical Practiceに準拠した遺伝子導入機を開発するとともに、安全にシステム制御可能なアルゴリズムを確立し、大型動物におけるその有用性の確認を行う。本研究を遂行することにより、疾患モデル大動物と非ヒト霊長類を用いた臨床試験前段階への移行が可能になると共に、薬物の細胞内直接送達という新規分野開拓に寄与する。

    researchmap

  • ”ソフトな財=経験”による若手人材育成

    2009.7 - 2014.3

    System name:科学技術振興調整費

    Awarding organization:文部科学省

      More details

    Grant type:Competitive

    若手研究人材が研究を通して学ぶベンチャー・ビジネス・ラボラトリーを基盤とし、地域共同研究センターおよび大学院との連携の下で、途切れることのない地域イノベーション創出のための地域中核人材の育成を図る。そのために経験による”ソフトな財”を、産官学コネクションズ・パートナーシップ等を活用して修得する。但し、実施対象組織や企業等との間で“ソフトな契約”を締結した上で、業種および企業の生産等が繁忙ではない時期を考慮して、本プログラム実施する。学びの場となる企業を公募することも含めて契約先を入念に決定し、幾つかの育成コースに分けてプログラムを実施する。契約先企業等との関係は有料、無料のいずれの場合もあり、必ずしも課題解決のみに固執せず、“有形無形の知の経験”修得を優先する。研修先とは互いに義務感と目的を共有し、”お客様ではなく、社員に限りなく近い実務経験”による本物のキャリア構築を図る。他方、ソリューション能力を活用し、地域社会での科学技術の理解促進や効果的理数教育支援、そのための施策の提案等もプログラムで学ぶ特徴の一つとする。

    researchmap

  • 地域中小企業の高学歴インターンシップ受入れ環境整備と新規産学連携ルート開拓

    2009.1 - 2009.3

    System name:平成20年度中小企業高度人材確保のための長期企業内実務研修制度整備委託事業

    Awarding organization:経済産業省

      More details

    Grant type:Competitive

    Grant amount:\10428000 ( Direct Cost: \9820196 、 Indirect Cost:\607804 )

    ポスドクや博士課程学生等の高学歴技術者がインターンシップを通じて地域で活躍する仕組みを構築するために、現状のインターンシップにおける問題点について調査し、情報の集積と分析を行うとともに企業、学校及び行政関係者で構成される運営協議会を設置し、インターンシップ研修が地域企業にとって人材確保の場に留まらず企業活動の活性化に繋げるための方策や、企業と技術者をつなげるコーディネータの役割及びその育成について検討した。
    これらの検討をもとに、高学歴技術者を対象とした新しい長期インターンシッププログラムを開発・試行するとともに有効性を検証し、地域に対して理解の促進を図った。

    researchmap

  • 4次元感覚センシング・フィードバックによるNIPPV用鼻マスク形状の最適化

    2007.4 - 2011.3

    System name:科学研究費補助金

      More details

    Grant type:Competitive

    researchmap

  • 4次元感覚センシング・フィードバックによるNIPPV用鼻マスク形状の最適化

    2007.4 - 2010.3

    System name:科学研究費助成事業

    Research category:基盤研究(C)

    Awarding organization:日本学術振興会

      More details

    Grant type:Competitive

    Grant amount:\3800000 ( Direct Cost: \2660000 、 Indirect Cost:\1140000 )

    本研究では個々人の顔形状に適した鼻マスクのオーダー・メイド・システムを構築するために,レーザー光による被験者の顔形状計測,超音波による軟部組織の厚さ計測,血流速計測などの基礎データを収集する.さらに,得られた形状データに基づき鼻マスク装着時を考慮した有限要素パーソナルモデルを構築し,FEM応力解析を利用して気密性を確保した上で血流を損なわないマスク形状の提案を行うと共に,感圧導電ゴムを用いた4次元触覚センシングシステム等を構築・適用し,鼻マスク装着時において作用する接触圧力分布,トラクション荷重分布ならびに血流速の実測結果とFEM応力解析結果を比較検討し,システムの実用性の評価を行う.

    researchmap

  • 国際的な産学官連携を進める上で問題となるアジア各国(中国・韓国等)と日本との特許制度における相違点に関する調査研究

    2006.9 - 2007.3

    System name:平成18年度21世紀型産学官連携手法の構築に係るモデルプログラム

    Awarding organization:文部科学省

      More details

    Grant type:Competitive

    環日本海沿岸諸国の特許制度の相違点とそこから派生する産学連携分野における適切な契約内容等のあり方について調査研究を行った.
    将来予測される諸問題が未然に解決され、国内技術を保護し円滑で効果的な国際的産学連携に寄与できるものと思われる.

    researchmap

  • 触覚センシングについての研究

    2004.4 - 2011.3

    System name:共同研究

      More details

    Grant type:Competitive

    researchmap

  • 超音波を利用した義足ソケット形状決定支援システム構築に関する研究

    2004.4 - 2007.3

    System name:科学研究費助成事業

    Research category:基盤研究(C)

    Awarding organization:日本学術振興会

      More details

    Grant type:Competitive

    Grant amount:\3900000 ( Direct Cost: \3900000 )

    下肢切断術後のリハビリテーション過程において,義足装着時の切端痛や皮膚の損傷が無視し得ない例が,極めて多く報告されている.義足の良否を決定する義足ソケットの適合に着目し,従来,「経験」や「勘」に基づく義足ソケット形状決定のプロセスを,超音波測長技術ならびにCAE技術を駆使することで,免荷と安定性を両立した義足ソケット形状の決定支援システムの構築を目指す.すなわち,義足ソケット装着により皮膚への圧迫や摩擦等により,皮膚の物理的損傷や血流等,生体にいかなる影響を及ぼすかを明らかにする.超音波測長で得られる軟部組織および骨組織の形状に基づき有限要素モデルを構築し,応力解析を行った結果に対し,前述の知見を適用することで,皮膚への負担を予測するとともに,いかなる義足ソケット形状が義足使用者に対し,負担が少ないかを明らかにする.

    researchmap

  • 義足ソケットの最適形状決定支援についての研究

    2000.4 - 2007.3

    System name:科学研究費補助金

      More details

    Grant type:Competitive

    researchmap

  • 車椅子操作時の非接触視点位置移動特性についての研究

    1996.4 - 2003.3

    System name:その他の研究制度

      More details

    Grant type:Competitive

    researchmap

  • 人工関節の接触メカニズムについての研究

    1995.4 - 1998.3

      More details

    Grant type:Competitive

    researchmap

  • ゴムしゅう動時のトライボロジー特性に関する研究

    1991.4 - 1995.3

    System name:その他の研究制度

      More details

    Grant type:Competitive

    researchmap

  • 新素材等の耐摩耗性に関する研究

    1986.4 - 1990.3

      More details

    Grant type:Competitive

    researchmap

▶ display all

 

Teaching Experience (researchmap)

  • ワーク・ライフ・バランス

     More details

  • 医学基礎

     More details

  • キャリアデザイン・インターンシップI

     More details

  • プロジェクト・マネジメント基礎

     More details

  • キャリアデザイン・インターンシップII

     More details

  • 総合技術科学演習

     More details

  • 工学リテラシー入門(融合領域分野)

     More details

  • 技術評価

     More details

  • 応用電子回路実習

    Institution name:職業能力開発総合大学校

     More details

  • 電子制御実習

    Institution name:職業能力開発総合大学校

     More details

  • 基礎力学

    Institution name:職業能力開発総合大学校

     More details

  • 計測工学

    Institution name:職業能力開発総合大学校

     More details

  • 福祉機器実習2

    Institution name:職業能力開発総合大学校

     More details

  • 機械制御実習

    Institution name:職業能力開発総合大学校

     More details

  • 計測実験I・II

    Institution name:職業能力開発総合大学校

     More details

  • インタフェース論

     More details

  • ユーザーインターフェースデザイン論

     More details

  • 技術者としてのキャリア形成入門演習

     More details

  • ディベートI

     More details

  • 組織工学実習

     More details

  • 知的構造・材料学

     More details

  • 先端機器・機械論

     More details

  • リメディアル演習

     More details

▶ display all

Teaching Experience

  • 産業技術政策特論

    2024
    Institution name:新潟大学

  • ロジカルスピーキング

    2024
    Institution name:新潟大学

  • 国際工学概論

    2024
    Institution name:新潟大学

  • 課題発見プロジェクト

    2024
    Institution name:新潟大学

  • 生産・品質管理基礎

    2024
    Institution name:新潟大学

  • 佐渡学概論:佐渡島の自然と人々の営み

    2024
    Institution name:新潟大学

  • 先端研究入門

    2023
    Institution name:新潟大学

  • 英文輪読II

    2023
    Institution name:新潟大学

  • くらしを支える機械システム工学

    2022
    Institution name:新潟大学

  • 機械工学概論

    2022
    Institution name:新潟大学

  • プロジェクトマネジメント演習

    2021
    Institution name:新潟大学

  • 技術・社会システム工学総論

    2021
    -
    2023
    Institution name:新潟大学

  • 技術者としてのキャリア形成入門演習

    2021
    Institution name:新潟大学

  • 総合技術科学演習

    2020
    Institution name:新潟大学

  • 協創経営概論

    2020
    Institution name:新潟大学

  • 課題解決インターンシップII

    2020
    Institution name:新潟大学

  • 工学リテラシー入門(融合領域分野)

    2020
    Institution name:新潟大学

  • 技術評価

    2020
    Institution name:新潟大学

  • 課題解決インターンシップIII

    2020
    Institution name:新潟大学

  • ディベートI

    2020
    -
    2021
    Institution name:新潟大学

  • 課題解決インターンシップI

    2020
    -
    2021
    Institution name:新潟大学

  • リメディアル演習

    2020
    Institution name:新潟大学

  • プロジェクト・マネジメント基礎

    2019
    Institution name:新潟大学

  • キャリアデザイン・インターンシップII

    2019
    -
    2022
    Institution name:新潟大学

  • 技術者としてのキャリア形成入門演習

    2019
    -
    2021
    Institution name:新潟大学

  • キャリアデザイン・インターンシップI

    2019
    -
    2021
    Institution name:新潟大学

  • ワーク・ライフ・バランス

    2016
    Institution name:新潟大学

  • 組織工学実習

    2009
    -
    2013
    Institution name:新潟大学

  • 知的構造・材料学

    2007
    Institution name:新潟大学

  • 先端機器・機械論

    2007
    Institution name:新潟大学

▶ display all

 

Social Activities

  • 佐渡工業会 ものづくり活動

    Role(s): Advisor

    佐渡工業会  2020.4

     More details

  • 第8回産学連携実務者ネットワーキング(UNITT2011)

    2011.9

     More details

    UNITT2011における「震災復興のための産学連携活動」セッションにおいてパネリストとして新潟大学の取り組みを紹介

    researchmap

  • 職業能力開発大学校カリキュラム等検討委員

    2010.11

     More details

    職業能力開発大学校能力開発研究センターが主催するカリキュラム等検討委員会において検討している「実習課題の授業評価」につきまして、外部委員として評価・検討を行った。

    researchmap

  • 佐渡新規産業創造塾

    Role(s): Advisor

    2010.10 - 2020.3

     More details

    佐渡市企業と月1回の研究会を開催し、産学連携活性化に繋げる。

    researchmap

  • 三条市成長産業分野進出研究会

    Role(s): Advisor

    2010.10 - 2012.3

     More details

  • 教員研修モデルカリキュラム開発プログラム講師

    2010.7

     More details

    新潟県立教育センターが実施する教員研修モデルカリキュラム開発プログラムに於いて,理科教員に科学技術や研究開発の現場を実際に体験・研究させ、地域企業・研究所と連携して、学校現場において実習内容を活用した理科授業を展開することにより、資質能力の向上を目的とし,近年の産学連携に関わる講演を行った。

    researchmap

  • 新潟発新規創業研究会

    2009.6 - 2011.3

     More details

    にいがたニュービジネス協議会が主催する同研究会に参画し、産学連携の活性化に繋げる。

    researchmap

  • つなぐしくみ新技術説明会講演

    2009.3

     More details

  • 第3回特許ビジネスin燕三条・評価アドバイザー

    2008.10

     More details

  • 平成20年度新現役チャレンジ支援モデル事業(にいがた新現役プロジェクト)推進委員

    2008.9 - 2009.3

     More details

  • 岩手大学地域連携推進センター外部評価委員

    2008.6 - 2009.3

     More details

  • 国際・大学知財本部コンソーシアム(国際活動支援部門リーダー,企画連絡調整部門委員)

    2008.4 - 2011.3

     More details

  • 平成19年度東北地区大学知的財産戦略研修会発表

    2007.12

     More details

    地域内相互連携による機能補完と知的財産マネジメント

    researchmap

  • 第2回特許ビジネスin燕三条・評価アドバイザー

    2007.10

     More details

  • 国際産学官連携フォーラム講演

    2007.6

     More details

    大学知的財産本部の調査研究により、各国における知的財産の取扱いの相違点など国際的な産学官連携を進める上での共通的な課題等について「国際的な産学官連携を進める上で問題となるアジア各国と日本との特許制度における相違点に関する調査研究-中国・韓国・ロシアについて−」と題して発表した.

    researchmap

  • (財)新潟インダルトリアルプロモーションセンター技術相談委員

    2007.4 - 2010.3

     More details

  • 佐渡地域資源活用委員

    2007.4 - 2008.3

     More details

  • 平成18年度中部地区大学知的財産戦略研修会発表

    2007.1

     More details

  • 新潟県知的財産機関連絡会委員

    2006.4 - 2007.3

     More details

  • 平成17年度東北地区大学知的財産戦略研修会発表

    2005.12

     More details

    地域内相互連携による機能補完と知的財産マネジメント

    researchmap

  • 平成16年度中部ブロック大学知的財産研修会発表

    2005.1

     More details

    知的財産の管理・活用体制等の状況報告

    researchmap

  • 新潟県大学連合知的財産本部事務局長

    2003.9 - 2008.3

     More details

  • 日本非破壊検査協会特別研究委員会において講演「AEを用いた表面処理鋼のトライボロジー特性評価」

    1997.3

     More details

    日本非破壊検査協会アコースティックエミッション特別研究委員会

    researchmap

▶ display all